HomeMy WebLinkAbout035 - H-2 - HVAC SCHED GAS-FIRED UNIT HEATER SCHEDULE ACCESSORIES: CONTROLS: 1.PROVIDE FACTORY MOUNTED DISCONNECT 1.7-DAY PROGRAMMABLE THERMOSTAT 2.HIGH ALTITUDE KIT 3.TOTALLY ENCLOSED FAN MOTOR ELECTRICAL DATA: 4.FOUR-POINT SUSPENSION/MOUNTING ISOLATION KIT SEE MEP COORDINATION SCHEDULE FOR STARTERIDISCONNECT 5.MANUAL SHUT-OFF AND UNION AND ALL OTHER ELEC.DATA. 6.TWO-STAGE NATURAL GAS VALVE 7.HORIZONTAL SEPARATED VENT/COMBUSTION AIR INLET TERMINAL KIT MARK MANUF. MODEL TYPE GAS CONN.(IN) INPUT/OUTPUT(MBH) COMBUSTION AIR(IN) VENT(IN) AIRFLOW(CFM) WEIGHT(LBS) UH-2 REZNOR UDXC 30 NATURAL GAS 314 30/24.6 4 4 456 1 57 LOUVER/CONTROL DAMPER SCHEDULE NOTES: 1.VERIFY ROUGH OPENING DIMENSIONS WITH CONSTRUCTION MANAGER PRIOR TO ORDERING. 2.6. DEEP DRAINABLE LOUVER WITH BIRDSCREEN. 3.PROVIDE MOTORIZED DAMPER AS INDICATED ON THE FLOOR PLANS. MARK MANUF. MODEL WIDTH(IN) HEIGHT(IN) TYPE MATERIAL FUNCTION FREE AREA(SO FT) COLOR NOTES CD-2A RUSKIN CD51 48 24 2-POSITION,24V CONTROL ALUMINUM EXHAUST N/A 3 CD-26 RUSKIN CD51 48 24 2-POSITION,24V CONTROL ALUMINUM EXHAUST N/A 3 CD-3 RUSKIN CD51 32 14 2-POSITION,24V CONTROL ALUMINUM RELIEF N/A 3 CD-4 RUSKIN CD51 48 72 2-POSITION,24V CONTROL ALUMINUM SUPPLY N/A 3 LV-2 RUSKIN ELF6375DX 48 48 STATIONARY STEEL EXHAUST 9.08 BYOTHER 1,2 LV-3 RUSKIN ELF6375DX 48 72 STATIONARY STEEL SUPPLY 14.04 BYOTHER 1,2 EXHAUST FAN SCHEDULE ACCESSORIES: CONTROLS: 1.STANDARD DISCONNECT PREWIRED. 1.CONTROL DAMPER MOTOR TO BE INTERLOCKED WITH FAN. 2.FAN SPEED CONTROLLER. 3.MOTORIZE CONTROL DAMPER. ELECTRICAL DATA: 4.WALL COLLAR SEE MEP COORDINATION SCHEDULE FOR STARTERIDISCONNECT AND ALL OTHER ELEC.DATA. 5.STANDARD FINISH. 6.ALUMIUM BIRD SCREEN. 7.45 DEGREE WEATHER HOOD. 8.VIBRATION ISOLATORS. 9.WALL CAP WITH INTEGRAL BACKDRAFT DAMPER. 10.PROVIDE ECM MOTOR WHERE AVAILABLE. MARK MANUFACTURER MODEL AIRFLOW(CFM) SONES ESP(IN WC) DRIVE TYPE MOUNTING CONTROL WEIGHT(LBS) EF-2 COOK 10XW24D17 300 6.9 0.2 DIRECT PROPELLER WALL ECM 59 MEP COORDINATION SCHEDULE CONTROL TYPE: DISCONNECT/STARTER TYPE: DIVISION OF RESPONSIBILITIES: BAS BUILDING AUTOMATION SYSTEM CB PANELBOARD CIRCUIT BREAKER WITHIN SIGHT OF EQUIPMENT 22/22 FURNISHED AND INSTALLED BY DIV.22,WIRED BY DIV.22 CO CARBON MONOXIDE DETECTOR CSFD COMBINATION STARTER/DISCONNECT-HOA 22/26 FURNISHED AND INSTALLED BY DIV.22,WIRED BY DIV.26 CONT CONTINUOUS OPERATION FD FUSED DISCONNECT 23123 FURNISHED AND INSTALLED BY DIV.23,WIRED BY DIV.23 EF INTERLOCK WITH EXHAUST FAN FST FUSTAT 23126 FURNISHED AND INSTALLED BY DIV.23,WIRED BY DIV.26 HCP HOOD CONTROL PANEL FW FACTORY-WIRED SINGLE POINT CONNECTION 26126 FURNISHED AND INSTALLED BY DIV.26,WIRED BY DIV.26 INT INTEGRAL MOCP MOTOR OVER-CURRENT PROTECTION L LIGHT SWITCH MSS MANUAL STARTER SWITCH WITH THERMAL OVERLOADS(1-,2-OR 3-POLE AS REQUIRED) NOTES: MS MANUAL SWITCH NFD NON-FUSED DISCONNECT 1.INTEGRAL DISCONNECTS AND OVERLOADS OS OCCUPANCY SENSOR RCPT 20A DUPLEX RECEPTACLE(GFCI PROTECTED AS REQUIRED),CORD AND PLUG 2.INTEGRAL OVERLOADS PS PRESSURE SWITCH RVSS REDUCED VOLTAGE SOLID-STATE 3.SINGLE POINT CONNECTION T THERMOSTAT VFD VARIABLE FREQUENCY DRIVE-HOA 4.SINGLE POINTCPROVIDE CONNECACLE TION DATA CONNECTION FOR PANEL TC TIMECLOCK N/A NOT APPLICABLE UC UNIT CONTROLLER 5.MOUNT ON UNI-STRUT IN FRONT OF UNIT VE VEHICLE EXHAUST DETECTION SYSTEM 6.SIZE FUSES IN ACCORDANCE WITH MANUFACTURER'S GUIDELINES FOR INSTALLED EQUIPMENT N/A NOT APPLICABLE 7.INTEGRAL VARIABLE FREQUENCY DRIVE IL DUCT SMOKE DETECTOR(S)REQUIRED GENERAL NOTES: A.CONTROL WIRING SHALL BE CONCEALED WITHIN WALL CONSTRUCTION,ABOVE CEILING,OR RUN IN CONDUIT.EXPOSED CONTROL WIRING IS UNACCEPTABLE. B.UNLESS SPECIFICALLY NOTED,ALL FEEDERS SHALL INCLUDE A FULL SIZE NEUTRAL.IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY WITH THE MANUFACTURER OF THE ACTUAL EQUIPMENT BEING SUPPLIED WHETHER A NEUTRAL IS REQUIRED PRIOR TO ROUGH-IN. C.ALL DUCT SMOKE DETECTORS FURNISHED BY DIV.26,INSTALLED BY DIV.23,AND WIRED BY DIV.26.DIV.26 SHALL WIRE ALL FANS TO SHUT DOWN WHEN ALARM IS INITIATED BY ANY DUCT SMOKE DETECTOR. MARK DESCRIPTION ELECTRICAL DATA CONTROL NOTES DISCONNECT/STARTER DISCONNECT FEEDER LOAD VOLT-PHASE TYPE DIV TYPE DIV SIZE(NEMA) SWITCH(AMPS) FUSE(AMPS) ENCLOSURE(NEMA) COPPER WIRE(AWG) CONDUIT(INCHES) EF-2 EXHAUST FAN 118 HP 120-1 T 23/23 MSS 26126 #12 314" UC-1 UNITCONTROLLER FRACTIONAL 120-1 N/A 23123 CB 26126 #12 314" UH-2 GAS-FIRED UNIT HEATER 1.9 AMPS 120-1 T 23123 MSS 26126 #12 314" `a E 9 8 AGENCY REVIEW (REVISION 2) JUNE 2025 o VERIFY SCALE! REVISIONS "q DRAWN BY: CMH PROJECT NUMBER NO. DESCRIPTION BY DATE O 10678.001 THESE PRINTS MAYBE Cr Morrison 0 9 DSGN.BY: CMH NORTON RANCH LIFT STATION UPGRADES REDUCED.LINE BELOW 2880 Technology Blvd West p� JOSEPH R. * SHEET NUMBER m MEASURES ONE INCH ON ■■ Bozeman,MT 59718 G S . APPR.BY: JRH BOZEMAN MONTANA 35 ORIGINAL DRAWING. Mai e r I e 406.587.0721 No.41135 PE DATE: 0612025 DRAWING NUMBER ® www.m-m.net �° <7CENSEO �W� Q.C.REVIEW HVAC SCHEDULES 8Z MODIFY SCALE ACCORDINGLY! engineers•surveyors•planners•scientists PS G BY: JRH H-2 PLOTTED ON:5/29/20253:26:32 PM COPYRIGHT®MORRi50N-MAiERLE,2023 S��'M w�AL�N DATE: 1/27/2025