HomeMy WebLinkAbout035 - H-2 - HVAC SCHED GAS-FIRED UNIT HEATER SCHEDULE ACCESSORIES: CONTROLS: 1.PROVIDE FACTORY MOUNTED DISCONNECT 1.7-DAY PROGRAMMABLE THERMOSTAT 2.HIGH ALTITUDE KIT 3.TOTALLY ENCLOSED FAN MOTOR ELECTRICAL DATA: 4.FOUR-POINT SUSPENSION/MOUNTING ISOLATION KIT SEE MEP COORDINATION SCHEDULE FOR STARTER/DISCONNECT 5.MANUAL SHUT-OFF AND UNION AND ALL OTHER ELEC.DATA. 6.TWO-STAGE NATURAL GAS VALVE 7.HORIZONTAL SEPAR4TED VENT/COMBUSTION AIR INLET TERMINAL KIT MARK MANUF. MODEL NPE GAS CONN.(IN) INPUT/OUTPUT(MBH) COMBUSTION AIR(IN) VENT QN) AIRFLOW(CFM) WEIGHT(LBS) UH-2 REZNOR UDXC 30 NATUR4L GAS 3/4 30/24.6 4 4 456 57 LOUVER/CONTROL DAMPER SCHEDULE NOTES: 1.VERIFY ROUGH OPENING DIMENSIONS WITH CONSTRUCTION MANAGER PRIOR TO ORDERING. 2.6"DEEP DR4INABLE LOUVER WITH BIRDSCREEN. 3.PROVIDE MOTORIZED DAMPER AS INDICATED ON THE FLOOR PLANS. MARK MANUF. MODEL WIDTH(IN) HEIGHT(IN) NPE MATERIAL FUNCTION FREEAREA(SQFf) COLOR NOTES CD-2A RUSKIN CD51 48 24 2-POSITION,24V CONTROL ALUMINUM EXHAUST N/A 3 CD-2B RUSKIN CD51 48 24 2-POSITION,24V CONTROL ALUMINUM EXHAUST N/A 3 CD-3 RUSKIN CD51 32 14 2-POSITION,24V CONTROL ALUMINUM RELIEF N/A 3 CD-4 RUSKW CD51 48 72 2-POSITION,24V CONTROL ALUMINUM SUPPLY N/A 3 LV-2 RUSKIN ELF6375DX 48 48 STATIONARY STEEL EXHAUST 9.08 BYOTHER 1,2 LV3 RUSKIN ELF6375DX 48 72 STATIONARY STEEL SUPPLY 14.04 BYOTHER 1,2 EXHAUST FAN SCHEDULE ACCESSORIES: CONTROLS: 1.STANDARD DISCONNECT PREWIRED. 1.CONTROL DAMPER MOTOR TO BE INTERLOCKED WITH FAN. 2.FAN SPEED CONTROLLER. 3.MOTORIZE CONTROL DAMPER. ELECTRICAL DATA: 4.WALL COLLAR SEE MEP COORDINATION SCHEDULE FOR STARTER/DISCONNECT AND ALL OTHER ELEC.DATA. 5.STANDARD FINISH. 6.ALUMIUM BIRD SCREEN. 7.45 DEGREE WEATHER HOOD. 8.VIBRATION ISOLATORS. 9.WALL CAP WITH INTEGRAL BACKDRAFT DAMPER. 10.PROVIDE ECM MOTOR WHERE AVAILABLE. MARK MANUFACTURER MODEL AIRFLOW(CFM) SONES ESP(IN WC) DRNE NPE MOUNTING CONTROL WEIGHT(LBS) EF-2 COOK 10XW24D17 300 6.9 02 DIRECT PROPELLER WALL ECM 59 MEP COORDINATION SCHEDULE CONTROL NPE: DISCONNECT/STARTER NPE: DNISION OF RESPONSI8ILITIES: BAS BUILDING AUTOMATION SYSTEM CB PANELBOARD CIRCUIT BREAKER WITHIN SIGHT OF EQUIPMENT 22/22 FURNISHED AND INSTALLED BY DIV.22,WIRED BY DN.22 CO CAR80N MONOXIDE DETECTOR CSFD COMBINATION STARTER/DISCONNECT-HOA 22/26 FURNISHED AND INSTALLED BY DIV.22,WIRED BY DN.26 CONT CONTINUOUS OPERATION FD FUSED DISCONNECT 23/23 FURNISHED AND INSTALLED BY DIV.23,WIRED BY DN.23 EF INTERLOCK WITH EXHAUST FAN FST FUSTAT 23/26 FURNISHED AND INSTALLED BY DIV.23,WIRED BY DN.26 HCP HOOD CONTROL PANEL FW FACTORY-WIRED SINGLE POINT CONNECTION 26/26 Fl1RNISHED AND INSTALLED BY DIV.26,WIRED BY DN.26 INT INTEGRAL MOCP MOTOROVER-CURRENTPROTECTION L LIGHTSWITCH MSS MANUALSTARTERSWITCHWITHTHERMALOVERLOADS(1-,2-OR3-POLEASREQUIRED) NOTES: MS MANUAL SWITCH NFD NON-FUSED DISCONNECT 1.INTEGRAL DISCONNECTS AND OVERLOADS OS OCCUPANCYSENSOR RCPT 20A DUPLEX RECEPTACLE(GFCIPROTECTEDAS REQUIRED),CORDAND PLUG 2,INTEGRALOVERLOADS PS PRESSURE SWITCH RVSS REDUCED VOLTAGE SOLID-STATE 3.SINGLE POINT CONNECTION T THERMOSTAT VFD VARIABLE FREQUENCY DRIVE-HOA 4.PROVIDE RECEPTACLE AND DATA CONNECTION FOR PANEL TC TIMECLOCK N/A NOTAPPLICABLE UC UNIT CONTROLLER 5.MOUNT ON UNI-STRUT IN FRONTOF UNIT VE VEHICLE EXHAUST DETECTION SYSTEM 6.SIZE FUSES IN ACCORDANCE WITH MANUFACTURER'S GUIDELWES FOR INSTALLEo E�UIPMENT N/A NOTAPPLICABLE 7.INTEGRAL VARIABLE FREQUENCY DRIVE 8.DUCT SMOKE DETECTOR(S)REQUIRED GENERALNOTES: A.CONTROL WIRMG SHALL BE CONCEALED WITHIN WALL CONSTRUCTION,ABOVE CEILING,OR RUN W CONDUIT.EXPOSED CONTROL WIRMG IS UNACCEPTABLE. B.UNLESS SPECIFICALLY NOTED,ALL FEEDERS SHALL INCLUDE A FULL SIZE NEUTRAL.IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY WITH THE MANUFACTURER OF THE ACTUAL EQUIPMENT BEING SUPPLIED WHETHER A NEUTRAL IS REQUIRED PRIOR TO ROUGH-IN. C.ALL DUCT SMOKE DETECTORS FURNISHED BY DIV.26,INSTALLED BY DIV.23,AND WIRED BY DIV.26.DIV.26 SHALL WIRE ALL FANS TO SHUT DOWN WHEN ALARM IS INITIATED BY ANY DUCT SMOKE DETECTOR. MARK oESCRIPTION � ELECTRICALDATA CONTROL NOTES �ISCONNECT/STARTER DISCONNECT FEEDER LOAD IVOLT-PHASE TYPE DN TYPE I DIV SIZE(NEMA) SWITCH(AMPS) FUSE(AMPS) ENCLOSURE(NEMA). COPPERWIRE(AWG) CONDUIT(INCHES) EF-2 EXHAUSTFAN 1/SHP 120-1 T 23/23 M55 26/26 -- -- -- -- #12 3/4" UC-1 UNITCONTROLLER FRACTIONAL 120-1 N/A 23/23 CB 26/26 -- -- -- -- #12 3/4" UH-2 GAS-FIREDUNITHEATER 1.9AMPS 120-1 T 23/23 M55 26/26 -- -- -- -- #12 3/4" 2 � � � AGENCY REVIEW (REVISION 2) JUNE 2025 veaiFv scn�et REVISIONS ,.•"N T�q'• DRAWN BY: CMH PROJECT NUMBER THESEPRINTSMAVBE NO. OESCRIPTION BY �ATE :�O �•� �9q DSGN.BY: CMH 10678.001 Morrison ;* JOSEPHR *� SHEETNUMBER `s ��' . NORTON RANCH LIFT STATION UPGRADES m Reouceo.uNe se�ow v 2880 Technology Blvd West • o MEoriiclNn�oaawMc�N ■■ Bozeman,MT 59718 BOZEMAN MONTANA 35 GH S APPR.BY: JRH � � �► �-o No.41135 PEf��; DRAWING NUMBER 8 - M a i e r I e .� � �. DATE: O6/2025 MODIFvscn�encmRoiNc�n '� www.m-m.net �5,�-c �/CENSEf\2�? Q�C.REVIEW HVACSCHEDULES o engineers surveyors planners scientists tiF,g G f BY: JRH H-2 Q PLOTTEDON:529I20253�.26�.32PM CO�vRIGHTOMORRI50N�Mni�.-viF�u�3 ~ti•..�NA��'�•f DATE�. 1I27I2025