HomeMy WebLinkAbout034 - H-1 - HVAC LGND ABBREVIATIONS MECHANICAL LEGEND MECHANICAL GENERAL NOTES INSTALLATION: ACC ARC OOLED CONDENSER ID INSIDE DIAMETER ANNOTATION SYMBOLS HVAC DUCTWORK(CONT.) PIPE FITTINGS A. NEW PIPING,DUCTWORK AND EQUIPMENTTO BE INSTALLED IN ACU AIR CONDITIONING UNIT IFB INTEGRAL FACE&BYPASS ACCORDANCE WITH THE CURRENTLY ADOPTED INTERNATIONAL AD ACCESS DOOR IGV INLET GUIDE VANES SUPPLY DUCT(SECTION VIEW] ELBOW MECHANICAL AND INTERNATIONAL BUILDING CODES. ADJ ADJUSTABLE IPS IRON PIPE SIZE B. EQUIPMENT SHALL BE INSTALLED LEVEL,PLUMB,AND FIRMLYANCHORED IN AF AIR FOIL IU INDUCTION UNIT X �3D VIEW NUMBER LOCATIONS INDICATED ON PLAN.OBSERVE MANUFACTURER'S AFF ABOVE FINISHED FLOOR X SHEET NUMBER RETURN DUCT(SECTION VIEW) PIPE BREAK INSTALLATION INSTRUCTIONS AND RECOGNIZED INDUSTRY PRACTICES TO AFG ABOVE FINISHED GRADE KW KILOWATTS ENSURE THAT PRODUCTS SERVE THEIR INTENDED FUNCTION. AFR ABOVE FINISHED ROOF KWH KILOWATT HOUR PIPE UP C. INSTALL EQUIPMENT,DUCTWORK,AND PIPING SO AS TO MAINTAIN CODE AFS AIR FLOW STATION O f DETAIL NUMBER EXHAUST DUCT(SECTION VIEW) REQUIRED CLEARANCES FOR ELECTRICAL AND TELECOMMUNICATION AHU AIR HANDLING UNIT LAT LEAVING AIR TEMPERATURE(°F) SHEET NUMBER EQUIPMENT. AP ACCESS PANEL LF LINEAR FEET PIPE DOWN D. ELEMENTS PENETRATING BUILDING COMPONENTS(ROOF ASSEMBLIES, ATC AUTOMATIC TEMPERATURE CONTROL LWT LEAVING WATER TEMPERATURE(°F) OF—] OUTDOOR AIR DUCT(SECTION VIEW) WALL ASSEMBLIES,ETC.)SHALL BE SEALED WEATHER AND WATER TIGHT. ATM ATMOSPHERE X SECTION NUMBER CHANGE IN ELEVATION OF PIPE COORDINATE PENETRATIONS WITH GENERAL CONTRACTOR TO PATCH TO AWG AMERICAN WIRE GAUGE M MOTOR OPERATED THE SATISFACTION OF THE ARCHITECT OR ENGINEER. MAU MAKEUP AIR UNIT X SHEET NUMBER DUCT UP(PLAN VIEW) E. EQUIPMENT MANUFACTURED AFTER 1/1/2023 SHALL MEET MINIMUM SEER2 B BOILER MB MIXING BOX SIDE CONNECTION,TEE FITTING RATINGS. BB BASEBOARD MBH 1000 BTU/HR e AIR DEVICE MARK AND CFM BC BACKWARD CURVED MC MECHANICAL CONTRACTOR CFM DUCT DOWN(PLAN VIEW) TOP CONNECTION,TEE FITTING UP COORDINATION: BD BACKDRAFT DAMPER MFR MANUFACTURER A. IT SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR TO BF BOILER FEED MS MINI-SPLIT X AIR DEVICE MARK AND CFM- 1 FIELD COORDINATE THE LOCATION OF EQUIPMENT,ROUTING OF BHP BRAKE HORSEPOWER CFM PROVIDE OPPOSED BLADE DAMPER INCLINED RISE-IN DIRECTION OF AIRFLOW _ BOTTOM CONNECTION,TEE FITTING DOWN DUCTWORK,AND ROUTING OF PIPING WITH OTHER TRADES. BI BACKWARD INCLINED NC NOISE CRITERIA OBD B. IT SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR TO BMS BUILDING MANAGEMENT SYSTEM NC NORMALLY CLOSED ;��p-�►��; CAPPED OUTLET OR BLIND FLANGE REVIEW THE DRAWINGS OF OTHER DISCIPLINES AND PROVIDE THE BOD BOTTOM OF DUCT NIC NOT IN CONTRACT X AIR DEVICE MARK AND CFM- INCLINED DROP-IN DIRECTION OF AIRFLOW ' NECESSARY LABOR AND MATERIALS REQUIRED FOR A COMPLETE BOJ BOTTOM OF JOIST NO NORMALLY OPEN CF PROVIDE RADIAL DAMPER INSTALLATION. BOB BOTTOM OF STEEL NPS NOMINAL PIPE SIZE RD �� CONCENTRIC REDUCER C. COORDINATE THE INSTALLATION OF GRILLES,REGISTERS AND DIFFUSERS BTU BRITISH OF UNIT INTERNAL DUCT LINING WITH THE ARCHITECTURAL REFLECTED CEILING PLANS,THE ELECTRICAL CA OUTSIDE AIR ME-# MECHANICAL EQUIPMENT MARK LIGHTING PLANS,AND IF RELEVANT,THE TELECOMMUNICATION AND FIRE C COMMON CAD OUTSIDE AIR DAMPER ELBOW WITH TURNING VANES SPRINKLER PLANS. CAV CONSTANT AIR VOLUME OBD OPPOSED BLADE DAMPER (E1 ME-# EXISTING MECHANICAL EQUIPMENT VALVES CC COOLING COILL ELECTRICAL COORDINATION: CCW COUNTERCLOCKWISE P PUMP D ME-# DEMOLISHED MECHANICAL EQUIPMENT \ R RADIUS ELBOW ] MANUAL BALANCING VALVE A. SEE THE MEP COORDINATION SCHEDULE FOR ELECTRICAL INFORMATION. CFM CUBIC FEET PER MINUTE PC PLUMBING CONTRACTOR ���LLL777 COORDINATE WITH OTHER TRADES TO ENSURE THAT ELECTRICAL CH CHILLER PD PRESSURE DROP QllPOINT OF NEW CONNECTION DISCONNECTS,MOTOR STARTERS,VARIABLE FREQUENCY DRIVES, C&I CONTROLS&INSTRUMENTATION PH PHASE MANUAL VOLUME DAMPER AUTOMATIC BALANCING VALVE CONTROLS,AND ELECTRICAL ACCESSORIES ARE FURNISHED AND/OR CLG CEILING PHC PREHEAT COIL C POINT OF DISCONNECTION INSTALLED BY THE APPROPRIATE TRADE. CMU CONCRETE MASONRY UNIT PPM PART PER MILLION VENTURI VALVE CND CONDENSATE PROP PROPELLER { REMOTE VOLUME DAMPER SITE ELEVATION: CONT CONTINUATION PRV PRESSURE REDUCING VALVE A. EQUIPMENT SHALL BE SELECTED FOR THE PROJECT ELEVATION OF 4,800'. CORR CORRIDOR PSIA PSI,ABSOLUTE o CT COOLING TOWER PSIG PSI,GAUGE HVAC CONTROL SYMBOLS m DC ISOLATION VALVE CU CONDENSING UNIT BACKDRAFT DAMPER CH CABINET HEATER QTY QUANTITY (T THERMOSTAT MANUAL 3-WAY VALVE CV CONTROL VALVE Q" ZONED THERMOSTAT ZONE DAMPERS STRAINER MECHANICAL SHEET INDEX CVS CONTROL VALVE STATION R REGISTER CW CLOCKWISE RA RETURN AIR NUMBER SHEET NAME RD RADIAL DAMPER dB DECIBEL RF RETURN/REUEF AIR FAN OzM ZONED THERMOSTAT-MASTER '�-- I/I CHECKVALVE H-1 HVAC LEGEND IDS DRYBULB TEMPERATURE(°F) RH RELATIVE HUMIDITY }f D BY—.DAMPER H-2 HVAC SCHEDULES DDC DIRECT DIGITAL CONTROL RHC REHEAT COIL n THERMOSTAT W/LOCKABLE COVER BACKFLOW PREVENTER H-3 HVAC DETAILS DH DUCT HEATER H-4 HVAC DEMOLITION PLAN DP DEW POINT TEMPERATURE(°F) SA SUPPLYAIR EfDMOTORIZED DAMPER DX DIRECT EXPANSION SAF SUPPLY AIR FAN % WALLSWITCH PRESSURE REDUCING VALVE H-5 HVAC PLAN SC SENSIBLE COOLER E EXHAUST SCFM CFM,STANDARD CONDITIONS HUMIDISTAT Cf3 FIRE DAMPER GAS PRESSURE REGULATOR EA EXHAUSTAIR SD SMOKE DETECTOR EAT ENTERING AIR TEMPERATURE(°F) SEER SEASONAL ENERGY EFFICIENCY RATIO TEMPERATURE AND/OR PRESSURE RELIEF VALVE EC ELECTRICAL CONTRACTOR SENS SENSIBLE Q ROOM TEMPERATURE SENSOR rrm, oTT rr FIRE/SMOKE DAMPER EDR EQUIVALENT DIRECT RADIATION SP STATIC PRESSURE A EER ENERGY EFFICIENCY RATIO SPS STATIC PRESSURE SENSOR ❑T ADJUSTABLE ROOM TEMPERATURE SENSOR �C-I HOSE-END DRAIN W/CAP EF EXHAUST FAN SS STAINLESS STEEL EFF EFFICIENCY SMOKE DAMPER ELEV ELEVATION T THERMOSTAT 0c COMBO ROOM TEMPERATURE&CO2 SENSOR BOILER DRAIN W/CAP ERV ENERGY RECOVERY VENTILATOR TA TRANSFERAIR crA SOLENOID VALVE ESP EXTERNAL STATIC PRESSURE TCC TEMPERATURE CONTROL CONTRACTOR ❑T ADJUSTABLE COMBO ROOM TEMP 8 CO2 SENSOR ET EXPANSION TANK TCP TEMPERATURE CONTROL PANEL GENERAL EWT ENTERING WATER TEMPERATURE(°F) TG TRANSFER GRILL V TOS TOP OF STEEL ❑H ROOM HUMIDITY SENSOR 2-WAY TEMPERATURE CONTROL VALVE (E)NAME EXISTING PIPE TO REMAIN F&T FLOAT&THERMOSTATIC TSP TOTAL STATIC PRESSURE FA FACE AREA TYP TYPICAL © ROOM CO2 SENSOR O, 3-WAY TEMPERATURE CONTROL VALVE FC FORWARD CURVED -----(D)NAME----- EXISTING PIPE TO BE DEMOLISHED FC FAN COIL UH UNIT HEATER FP FIRE PROTECTION UNC UNDERCUT © BUILDING PRESSURE SENSOR STEAM TRAP NAME NEW PIPING FPM FEET PER MINUTE UV UNIT VENTILATOR FT FEET SP STATIC PRESSURE SENSOR VA VOLT-AMPERE r DIRECTION OF FLOW GA GAUGEORGAGE VAV VARIABLE AIR VOLUME PIPING SPECIALTIES GC GENERAL CONTRACTOR VD VOLUME DAMPER DIFFERENTIAL PRESSURE SENSOR GEN GENERATOR VEL VELOCITY AUTOMATIC AIR VENT GH GRAVITYHOOD VFD VAR IABLE FREQUENCY DRIVE CO/rv0 CARBON MONOXIDE/NITRIC OXIDE SENSOR HVAC PIPING GPD GALLONS PER DAY VRF VARIABLE REFRIGERANT FLOW MANUAL AIR VENT GPH GALLONS PER HOUR HWS HEATING WATER SUPPLY GPM GALLONS PER MINUTE WB WET BULB TEMPERATURE(°F) -- -- -- -- WC WATER COLUMN HVAC DUCTWORK T PRESSURE TEMPERATURE PORT H HUMIDIFIER WG WATER GAUGE ----HWR---- HEATING WATER RETURN HC HEATING COIL WSHP WATER SOURCE HEAT PUMP RECTANGULAR DUCT I— UNION OR FLANGE HG MERCURY W'zD" WIDTH x DEPTH —-—CWS—-— CHILLED WATER SUPPLY HOA HAND-OFF-AUTOMATIC AT TEMPERATURE DIFFERENCE(°F) HP HORSEPOWER v ROUND DUCT PIPE WELL-EMPTY HR HOUR X'e DIAMETER -- CWR -- CHILLED WATER RETURN T HX HEATEXCHANGER v TEMPERATURE SENSOR OVAL DUCT - CTS - COOLING TOWER SUPPLY WIDTH/DEPTH P PRESSURE SENSOR FLEXIBLE DUCT —--—CTR—--— COOLING TOWER RETURN +}(}X'e}H-F DIAMETER 'I FLOW SWITCH FLOOR/CEILING SUPPLY DIFFUSER —HPWS----- HEAT PUMP WATER SUPPLY PRESSURE SWITCH --- HPWR -- HEAT PUMP WATER RETURN P T FLOORICEILING RETURN GRILLE PRESSURE GAUGE,SNUBBER&NEEDLE VALVE -----HPS----- HIGH PRESSURE STEAM QT aFLOOR/CEILING EXHAUST GRILLE tir TEMPERATURE GAUGE E —MPS----- MEDIUM PRESSURE STEAM y b SIDEWALL SUPPLY DIFFUSER FLEXIBLE CONNECTOR - — - LPS- — - LOW PRESSURE STEAM ® THERMAL/SEISMIC EXPANSION LOOP 4 SIDEWALL RETURN/EXHAUST GRILLE -----------CND----------- STEAM CONDENSATE RETURN PIPE GUIDES 8 - ATV - ATMOSPHERIC VENT ANCHOR e --------REF-------- REFRIGERANT(LIQUID AND SUCTION) AGENCY REVIEW (REVISION 2) 2 NOTE:THIS IS A STANDARD LEGEND.NOT ALL PIPE TYPES AND F SYMBOLS ARE NECESSARILY UTILIZED IN THE DRAWINGS. FLOW METER JUNE 2025 ZVERIFYSCALE! REVISIONS 14 T q DRAWN BY: CMH PROJECT NUMBER NO. DESCRIPTION BY DATE O 10678.001 THESE PRINTS MY BE Cr Morrison 0 9 DSGN.BY: CMH NORTON RANCH LIFT STATION UPGRADES REDUCED.LINE BELOW 2880 Technology Blvd West =* JOSEPH R. * SHEET NUMBER m MEASURES ONE INCH ON ■■ Bozeman,MT 59718 G 9 . APPR.BY: JRH gOZEMAN MONTANA 34 ORIGINAL DRAWING. Mai e r I e ` 406.587.0721 No.41135 PE o• DATE: 0612025 DRAWING NUMBER ® www.m-m.net �3 <'CENSEO �W� Q.C.REVIEW HVAC LEGEND 8Z MODIFY SCALE ACCORDINGLY! engineers•surveyors•planners•scientists %PS G BY: JRH H-1 PLOTTEDON:5/29120253:25:25PM COPYRIGHT@MORRISON-MAIERE,2023 S��'M NAL DATE: 1/27/2025