Loading...
HomeMy WebLinkAbout030 - M-2 - LIFT STN PLANGNG NG NG SSSSSSGNG NG NG SSSSSSSSSSEEEEEEEEEEEEEEEEEEEEEEEESSSSSSSSSSSSSSSSSSSSSSSSEEEEEEEEEEEEBP BP BP BPVERIFY SCALE!THESE PRINTS MAY BE REDUCED.LINE BELOW MEASURES ONE INCHON ORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY!2025COPYRIGHT © MORRISON-MAIERLE,SHEET NUMBERPROJECT NUMBERDRAWING NUMBERDATEDESCRIPTIONNO.BYP:\10678-LAUREL PARKWAY LLC\001 - NORTON RANCH LIFT STATION\ACAD\SHEETS\4-MECHANICAL\M-2_LIFTSTATIONPLAN.DWGREVISIONS DRAWN BY:DSGN. BY:APPR. BY:DATE:Q.C. REVIEWDATE:BY:2880 Technology Blvd WestBozeman, MT 59718406.587.0721www.m-m.netengineers surveyors planners scientistsMorrisonMaierlePLOTTED BY:LEE HAGEMAN ON Jun/04/2025 NORTON RANCH LIFT STATION UPGRADES BOZEMANMONTANALIFT STATION PLAN10678.00130M-2KJSLRHLRH06/2025 24120SCALE IN FEETAGENCY REVIEW (REVISION 2)JUNE 2025RELOCATED GENERATOROVERHEAD GAS-FIRED HEATER(SEE HVAC)INTAKE LOUVRE(SEE HVAC)GENERATOREXHAUST PIPE(SEE HVAC)FUEL TANK VENT(S)FUEL FILL LOCATIONNEW 3'0" DOOR(SEE STRUCTURAL DWGS)NEW DOUBLE DOOR(SEE STRUCTURAL DWGS)ELECTRICAL EQUIPMENT(SEE ELECTRICAL DWGS)GENERATOR ROOM EXTENSION PRESERVE EXST 6"GATE VALVE (TYP.) PRESERVE EXST 6" GATESWING CHECK VALVE (TYP.) PRESERVE EXSTPRESSURE GAUGE (TYP.)PRESERVE EXST. 6"FLEXIBLE COUPLING (ETC.)6" FLOW METER6" FLOW METER PRESERVE EXST 6"FITTING (TYP.) PRESERVE EXST 6"DUCTILE IRON PIPE ANDPLUG TO THE EXTENTSSHOWNPIPE SUPPORT (TYP.)6" 90° BEND6" 90° BEND6" 90° BEND6" 90° BEND6" 90° BEND6" 90° BEND6" V4056" TEE6" V4056" V4056" FLEXIBLE COUPLINGEXST 4" SDR-26PVC FORCE MAINEXST 6" SDR-26PVC FORCE MAIN6" X 8" MJ CONCENTRIC REDUCER8" MJ 90° BENDEXST GAS METER(PRESERVE)EXST GAS SERVICE (PRESERVE)PRESSURE GAUGE(0-100 PSI)PRESSURE GAUGE(0-100 PSI)EXST. DOUBLESWING DOOR6" SS PSEE YARD PIPING PLAN FORCONTINUATION (SHEET C-8)8" FM PVC(SEE SHEETSC-10-C-13)6" TEE6" MJ 90 ° BENDBM-3A M-3 CM-3GENERAL NOTES1.ALL MANIFOLD PIPING AND FITTINGS SHALL BE CLASS 51 DUCTILEIRON WITH FLANGED CONNECTIONS, UNLESS OTHERWISE NOTED.2.BURIED PIPING SHALL UTILIZE MJ CONNECTIONS.AIR/VACUUMRELIEF VALVEKEY NOTESFLOW METER SHALL BE BADGER ELECTROMAGENTIC FLOWMETER MODEL M5000 WOTH 6" FLANGED CONNECTIONS. REFERTO ELECTRICAL FOR CONNECTION TO CONTROLS.1119.003.336.26'4.00'2.87'2.87'2.84'5.91'2.67'3.17'RELOCATED 2" CURBSTOP ON FLOOR DRAINDISCHARGE PIPE(SEE SHEET C-9 FORCONTINUATION)05/29/2025AIR/VACUUM RELIEF VALVEPRESERVE EXST 2" FLOORDRAIN PIPEFE/FIT100-1FE/FIT100-2NEW ELECTRICAL SERVICEEXHAUST FAN(SEE HVAC)EXST LOUVRETRANSITION TO C900 PVC6" SS PFIXED PANE WINDOW