Loading...
HomeMy WebLinkAbout029 - M-1 - LIFT STN DEMO PLAN EXST 6"FORCE MAIN EXST 4"FORCE MAIN DISCHARGE� i i�DISCHARGE DEMOLISH EXISTING 6"PIPING, PRESERVE EXST 6"DUCTILE � I FITTINGS,AND VALVES AS SHOWN IRON PIPE,RTTINGS,AND I I I �O APPURTENANCE(TYP.) I I EXST 6"FLOW METER TO BE � REMOVE EXST CURB STOP FROM � I I �1/� EXST 4"FLOW METER TO BE REMOVED AND SALVAGED BUILDING FLOOR DRAIN AND I I REMOVED AND SALVAGED O DOWNSTREAM PIPING TO EXST J� _ 1O WET WELL f-- --------------_ I� I I PRESERVE EXST 2"FLOOR I I I I I I I I I I I I DRAIN AND RE-ROUTE TO NEW I I I I I I I I I 15"MAIN WITH SERVICE WYE I I I I � � I I � � I I I I � � � � � � I I I I � � � � � � .____- _____._ I I � � � � � � ___.__ ____.____-_ ___-____ I I �-- I I � � I I I I - � . i� '�� ----� � I��� PLUG&ABANDON I I I I I I I I ❑ DEMOLISH EXISTING PIPE, I � ______ _______.__ I I �'�-�� �- ---- _ I I I��� � EXST 4"FORCE MAIN I I I I DISCHARGE PIPING I I I I I I I I EXST 6"FORCE MAIN I I FITTINGS,AND APPURTENANCES EXST GENSET TO BE RELOCATED TO NEW I I � � I I I I �DISCHARGE _ AS SHOWN. GENERATOR ROOM TO ACCOMMODATE REVISED �, �� �� �� — - - -�ss -�-�-.- _5� _ _ _-_ss-- -- I O DISCHARGE MANIFOLD CONFIGURATION �{�- I � � � � I �� � ____-____-__a9-_____._ � ' .. -_-__ `�_____-_.________.-_-.- ❑ -- EXST 6"INLET PIPING FROM WET WELL _ _ — �-- � � �A� DEMO SECTION 3 ,.5 ° 3 6 �iir -- — — i i ���^---- _ ___ � I I _ SCALE:1"=3' SCALEWFEET PLUG AND ABANDON EXISTING 4"DISCHARGE PIPING II II IN PLACE PER SPECIFICATIONS I I j---�� � ' � i DEMOLISH EXISTWG 6"PIPING, B � i RTTINGS,AND VALVES AS SHOWN _ i i � � li iJ =_==_=__-= II i �________ EXST 4"FLOW METER TO BE DEMOLISH EXST BURIED 6"PIPING � c REMOVED AND SALVAGED TO EXST WET WELL I� \ \ �.� � � 1 � � � � � - � PIPE TO BE CUT AT PROPOSED - CONNECTION POINT FOR NEW PIPING TO NEW WET WELL i i EXST 6"FLOW METER TO BE REMOVEDANDSALVAGED PRESERVE EXISTING EXTERNAL BYPASS � �O PIPING AND WALL PENETRATION FOR ¢ , CONNECTION TO REVISED MANIFOLD PLUG&ABANDON EXST 4"FORCE MAIN PRESERVE EXISTING EXTERNAL DISCHARGE PIPING BYPASS PIPING AND WALL � PENETRATION FOR CONNECTION TO REVISED MANIFOLD EXST 6" DISCHARGE� �1� DEMO PLAN Z � a Z 4 � _ SCALE:1"=2' o SCALE IN FEET ¢ �\ o N� 0 a ' GENERAL NOTES �� DEMO SECTION 3 '.5 o a s � ¢ 1.EXISTING ELECTRICAL AND HVAC ITEMS ARE NOT SHOWN FOR SCALB 1"=3' SCALE W FEET - DRAWING CLARITY. ¢ � < KEY NOTES g O SALVAGE AND REUSE EXISTING FITTINGS. DISPOSE OF EXISTING o VALVES UNLESS OTHERWISE NOTED. ¢ UQ K O ° AGENCY REVIEW (REVISION 2) JUNE 2025 J veRiFvscn�enNoco�oR! REVISIONS l`U DRAWNBY: KJS PROJECTNUMBER � THIS SHEET MAV BE REOl10ED AND IS ;�1`�I AI�J ��� y iNTENDEDToeEwCo�oR.THeanR NO. DESCRIPTION BY DATE ;C�` � �� 10678.001 ee�owwa�mensuReoNeiNCHnr Morrison � 2880TechnologyBlvdWest DSGN.BY: LRH NORTONRANCHLIFTSTATIONUPGRADES �i} *I'4� SHEET NUMBER a oRiciNn�oesicNscn�enNorzeo, ■■ Bozeman,MT 59718 (� wl APPR.BY: LRH gOZEMAN MONTANA 29 GREEN,ANO BLl1E WILL BE VISIBLE IF • REPRODUCE�TLV. 4OS.5B7.O7Z'I rA W� � M a i e r e � No 48 6 PE=J DATE O6/2025 DRAWWG NUMBER �'r� q o/zv/zozs MooiF sca�enccoRONc�v� � www.m-m.net r�sSp��57EREo�G� q.C.REVIEW LIFTSTATION DEMOLITION PLAN M�� engineers surveyors planners scientists �'4�ONAL`�` BY� a PLOTTED BV'.LEE HAGEMAN ON JUN04/2025 COPVRiGHT�OMORRISON-MAIERLE,2025 DATE: