HomeMy WebLinkAbout012 - C-5 - OVERALL SITE PLAN I
� GENERALNOTES
��
�
� EXISTING ASPHALT PATH 1.BLOCK FRONTAGE CLASSIFICATION(VAUGHN DRIVE):LANDSCAPE
I EXISTING NATURAL GAS 2.BLOCK FRONTAGE CLASSIFICATION(LAUREL PARKWAY):LANDSCAPE
EXISTING 4I'SDR-26 PVC
PROPOSED BUILDING
�
FORCEMAW � EXPANSION --
-- - PLANTINGS TO MEET REQUIREMENTS OF BMC 38.510.030.0
- (APPROX.LOCATION) ___ -------
� 4 � __----_-- --
. -- - 4.A DEPARTURE FROM FACADE TRANSPARENCY REQUIREMENTS HAS
� � _--_-_-_--
� -- BEEN REQUESTED IN THE PROJECT NARRATIVE DUE TO THE SIZE
I ----_
- PROVIDE EXPANSION JOWT AT AND NATURE OF THE FACILITY.
I Q �
I
� . � CONCRETE INTERFACE WITH BUILDING
8"FORCE MAIN TO
- , COTTONWOOD RD
I I I J �
. �g _ _ _ ___ --- -- ------------ (SEESHEETSC-10-
EXISTING WNCRETE � � I DOWEL NEW CONCRETE TO._.-------- INSTALL 6"REINFORCED CONCRETE G13)
EXISTWG 6"SDR-26 PVC DRNEWAY ACCESS c� _ EXISTING CONCRETE WITH#4 DRIVEWAY EXTENSION
FORCEMAW ---�---------
(APPROX.LOCATION) i : � X 18"BAR SPACED 15"O.C.,
CENTERED IN SLAB(TYP.) SB9°3rzr'win.3o'
�Q � CONCRETE JOINT(TYP.)
I �
�
I
� I � .4 ❑ --- � 2170'
� . � �' O , ___
� . . z 11.08'
/_'.
� FM FM FM FM . FM FM FM �(P ryi �;I � I �
� I� � � - 4 � � . p� .. . � �o�� . . . � .4 a/( � � � -1-_ � - - -
\ L rni 4 � 4 n �- `� � 26I41' 4 -_ � --- -------
s�\ i FA,I FM FM FM FAa—� EM F�M � . �F Ii ^ I� I I / 7 --_ 1HZ4' ----_— Q-- Q — —_—
� � � � � � � � � � � � � � � / - �� / � �
S I a a � � � ..� ,_'���I I I I . v `�- � ��,��9.,t.� ., �� i GENERA E EXISTING �� �// ^..���..��. ` A __
� I � II � RELOCAT �
� I 15.00' ., A II � � ���(((��� . � � 4 /(
� I . I � � FRONT SETBACK � ,m, FJ,���,,� � G TOR AS SHOWN I �. � d .� p O O�
G �� � � \/ X_
�s� EXISTWG MANHOLE � � �.. 4� ������� .�,��� __,,. �� . � � � I I �: 4 I �. � I . � � �
� �� � i I I � � RECONFIGURELIFTSTATION ��II � �� � - -- 2641 I I � I I`�� L�,--'--f_ �
� CONNECT TO EXISTING 6" � <i� _ -, {
3 �S\ � I . � � m PIPING TO BUILDING(TYP.) MANIFOLD PER SHEET M-2 ,I I I � � . � � . . - ���
� /� �� I � � �� �`�� � � REAR SETBACK �
��=� LIFT STATION POWER
� �� �� � � �I� AND CONTROL CONDUIT � �
�
�� ��� � � � �� EXTEND 2"FLOOR DRAIN � (SEE ELECTRICAL DWGS) ��
I � I � I N AT2%MINSLOPE �� � I � O OO
�I :� �
� I I �I�--6.00'-�� � I I PROPOSED FORCE MAIN "g 1200' �� � �
� � I� i � r�M—. 53—— � I I
� Q � I I~� RELOCATED 2"CURB STOP FOR �� �_� �� �`� o 0 0
� � PROPOSED SIDEWALK-6"DEPTH FLOOR DRAIN PIPE �� I I I� ELECTRICAL � O —
HANDHOLE �� �O pO-
� Y (COBSTDDRAWWG02529-11) � I��' II II � --�-- I I - � � -
INSTALL 4"X 2"ECCENTRIC I I �P��F�� �
�
� � ��
� i I I (SEE SHEET E-8) [i . Q �
� RE�UCER DOWNSTREAM �� I I I I I I . r' INSTALL 6"DIA.
II CONCRETE FlLLEDz
Q I II II II F I I
� Nc� m PROPERTY BOUN�ARY(TYP.) I I I I I I I ' � e�}}-E E e � E� �STEEL BOLLARD
I � Nc N� � EXST.GAS �� E e E E F E E E E P F e � �(TYP.OF10)
I w � Nc-- I SEVICE I I I I E c L FL� E E -
� � � �ro � ��� � I I I I I I �+ i E E�-r�-e E E E �12.Oo' � i�'i
�PROPOSED
� I G I I I I I � 20.00' I I E - �� m O GRAVEL ACCESS PATH
I � m �� I I I I -� I I ps 94, � 6.83' 6.83' � (SEE DETAIL 4 ON
�� ��
--------------
� J I I I� ti � m II II / -------------- -� ----___---__--- � SHEETSD-2)
� NEWGRAVITYSEWERTO NEWTRANSFORMERLOCATION I � �' �� II _ �� ____________________ i � ,�
g PROPOSEDWETWELL INSTALLNEW7'X7' ' - ------- � �'� �
- --__
(SEE SHEET C-9)
TRANSFORMERPAD Nc �I �� NEWELECTRICAL=-===- ---- � I � O� QO
- ---------------------------------
----___
il i I Q NG—______N II � METER SERVICE PANEL
-__ I
-__----__-- _�_ I
I i � 7.00' -� ' ------------------ _- __ a --_-_----
I
y I �� 1.50'(TYP.) �
� �----------------- ---- ------ --- --------- m --------------�- � ��7�
ti ________ ____ m
� _
I - ------- _ __
a
m ---------- -------------
------------- ----- --_______ oF � PROPOSED9'X12'WETWELL
� �' ' � I � — ----
o �, m ---------N� ______________� iO (SEESHEETSM-4&M-5)
EXISTING CURB � � 4"SDR-26 PVC ROOR DRAIN z z� w I
EXISTING 8"DUCTILE I � ---
IRON WATER MAIN � Ly EXTENSION TO NEW SERVICE WYE I � � � -
� � � ---� �� BP eP P-(SEE SHEET C-9) Bp ep 6"BURIED PIPING O �� �O��
I (SEE SHEET C-8) �
� -
N se ne•oa•e i2o.00• 6.83' 6.83' 1�
3 I v,
I
I I �'�'� ��'
I _"�"�"'_' "� '� ��
_ "'� "'_"�"'_
� I N
I �
"�"'�' "�"'�'
Qa '�"�"' �"�"'
J � � m "��"� 155"_"'_�"��"� '� N
NEW 8"SEWER STUB TO EAST
iss iss iss tss
iss��Sg iss �55 F (SEE SHEET C-9)
� iss iss i s iss �
155 15$ W
J I I I 155 W 5 15S i5S i5S
� � Q 15S 15S i5S 155 15S S
O � I I I I W ��iSS SS 8 SB�
m � 1
� I I W �
� �
V I � i 1 � NEW ELECTRICAL j
I � SERVICETOBUILDWG �
� I � � � � NEW GRAVITY SEWER TO �
� � I � Z PROPOSED WET WELL � � -N-
� � � � (SEE SHEET C-9) �
� I i x
o I � � EXISTING BURIE� w
Q I � I ELECTRICAL I EXISTING POND
J 3 I I I RESTORE TO ORIGINAL �
j CONDITION I
� I I I � — ; ; i ; 6 3 0 6 12
1
o I I j— ~ — — — — — — _ _ � � SCALE IN FEET
° � � i a ; - - - - - - - - - - - - - - - - �GENCY REVIEW (REVISION 2)
� I I I � � I - - - - JUNE 2025
J veRiFvscn�enNoco�oR! REVISIONS l`U DRAWNBY: KJS PROJECTNUMBER
� THIS SHEET MAV BE REOl10ED AND IS ;�1`�I AI�J ���
y iNTENDEDToeEwCo�oR.THeanR NO. DESCRIPTION BY DATE ;C�` � �� 10678.001
ee�owwa�mensuReoNeiNCHnr Morrison � 2880TechnologyBlvdWest DSGN.BY: LRH NORTONRANCHLIFTSTATIONUPGRADES
�i} *I'4� SHEET NUMBER
a oRiciNn�oesicNscn�enNorzeo, ■■ Bozeman,MT 59718 (� wl APPR.BY: LRH gOZEMAN MONTANA �Z
GREEN,ANO BLl1E WILL BE VISIBLE IF •
REPRODUCE�TLV. 4OS.5B7.O7Z'I rA W�
� M a i e r e � No 48 6 PE=J DATE O6/2025 DRAWWG NUMBER
MooiF sca�enccoRON��v� engineers surveyors planners scientists � `"`"`"'m-m.net !``4�,nSF�sALE��c�= e C.REVIEW OVERALLSITEPLAN
C-5
a PLOTTED BV'.LEE HAGEMAN ON JUN04/2025 COPVRiGHT�OMORRISON-MAIERLE,2025 DATE: