Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
007 - G-7 - P&ID LGND & NOTES
RADIATION(+) WHEN USED, EXPLANATION IS SHOWN ADJACENT TO INSTRUMENT SYMBOL. SEE ABBREVIATIONS AND LETTER SYMBOLS.POSITION, DIMENSIONEVENT, STATE OR PRESENCEWEIGHT, FORCE, TORQUEVIBRATION, MECHANICAL ANALYSISMULTIVARIABLE (+)TEMPERATURESPEED, FREQUENCY, SOLENOIDPRESSURE, VACUUMUNCLASSIFIEDMOISTURETIME, TIME SCHEDULECURRENT (ELECTRICAL)FLOW RATECONDUCTIVITYBURNER, COMBUSTIONANALYSIS (+)INITIATING VARIABLEPROCESS ORFIRST LETTER (S)FLAPSTOP LOGSVOLUME BOOSTERON LOSS OF PRIMARY POWER(PNEUMATIC, ELECTRICALXX: FO=FAIL OPENFC=FAIL CLOSEDFLP=FAIL TO LAST POSITION=INTERFACE LETTER=DESIGNATION DRAWING NO.=SOURCE DRAWING NO.PROCESS OR SIGNAL LINECONTINUATION N=1,2,3,ETC.INTERFACE TO OR FROMPROCESS EXTERNAL TOPROJECTNSA OR aDN=PROCESS INTERFACE=SIGNAL INTERFACEINTERFACE SYMBOLSSAHXXHYDRAULICDAW/ POSITIONERW/ SOLENOIDW/ POSITIONERELECTROHYDRAULICEHXXXXZEEELECTRICELECTRICXXSPPNEUMATICZPXXPNEUMATICNOTE:OR HYDRAULIC)MANUALACTUATOR SYMBOLSSPSOLENOIDPNEUMATIC WITHXXBRUPTURE DISKVAERATION DIFFUSERVENT TO ATMOSPHERERADIO ANTENNASELF CONTAINEDAIR SUPPLYAMORMORVOICE COMMUNICATIONPOINTPRESSURE GAUGEELECTRIC MOTORPIG CATCH POINTMIXERPIG INSERT POINTSEAL WATER SETHOSE ADAPTORDAMPENERPULSATIONSWATER SURFACEFLUSHING CONNECTIONFULTRASONICMAGMETERAVERAGING PITOTTHERMAL MASSPRESSURESIGHT GLASSDIAPHRAGM SEALBLIND FLANGEAIR GAP480V120VTRANSDUCER(LEVEL)ULEVELULTRASONICROTAMETERWEIRFLUMELEVEL (TRANSDUCER)MISCELLANEOUS SYMBOLSANNULAR DIAPHRAGM SEAL480 VOLT, 60 HZ POWER120 VOLT, 60 HZ POWERBASKET STRAINERY STRAINERREDUCER(BUBBLER TUBE)STRAIGHTENINGRESTRICTIONFLOAT LEVELBUBBLER LEVELLEVELVANESORIFICEORIFICETELESCOPINGPRESSURE CONTROLFOUR-WAY PLUGTHREE-WAY PLUGDIAPHRAGMMINOR EXISTING PROCESSMAJOR EXISTING PROCESSBACKFLOW PREVENTERAIR AND/OR VACUUM RELIEFFABRICATED SLIDEGATES AND VALVE ACTUATORSBALL CHECKDOUBLE DOOR CHECKBUTTERFLYSLUICENEEDLESSAMPLE TAPGATE SYMBOLSSHEARECCENTRIC PLUGPRESSURE RELIEFBUTTERFLYSWING CHECKGATEBALLPLUGGLOBESTARANGLESEAT PORTVALVESPRESSURE RELEASEFLOATPINCHLINE SYMBOLSPROCESS LINESMINOR PROCESSMAJOR PROCESSPITOT TUBETURBINEPRIMARY ELEMENTS/METERSPROPELLER ORREGULATED SIDEABRSIPLATEVENTURIORIFICECON-TDX-SECOFF-TDX-SECORIABXXQUICK CHANGEFLOW TUBEVORTEXRSRS D8ZXYWVON/OFFRTQUTSTORQUEQPONQUANTITY INSTRUMENTATION/LOGIC/FUNCTION SYMBOLSXXXXXPTFICFIC D8HSXXXXXHSD1-1IKMLJMOTIONLEVELPOWERHGFEHANDGASVOLTAGEIDBDCADENSITY PIPE CAPFLEX HOSEHOSE CONNECTIONMANUAL DRIP TRAPFLAME ARRESTERTFCALIBRATIONCOLUMNTANK INSULATIONAUTOMATIC DRAIN TRAPDDIAPHRAGM PUMPPISTON PUMPXXXXCHEMICAL FEED PUMPGEAR PUMP OR BLOWER(POSITIVE DISPLACEMENT)XXXXEJECTORCOMPRESSOR (PISTON)BLOWER OR TURBINECOMPRESSOR (CENTRIFUGAL),XXXXROCK TRAPDRAINCS-1 CONSTANT SPEED (SINGLE SPEED)CS-2 CONSTANT SPEED (TWO SPEED)PUMP AND COMPRESSOR SYMBOLSAS ADJUSTABLE SPEEDCENTRIFUGAL PUMPCENTRIFUGAL WET PITPUMP OR TURBINE PUMPXXXX(DRY PIT)NOTE: XX:SUBMERSIBLE SUMP PUMPPROGRESSIVE CAVITY PUMPXXXX3. THIS IS A STANDARD LEGEND, THEREFORE, NOT ALLOF THIS INFORMATION MAY BE USED ON THIS PROJECT.4. SEE ELECTRICAL LEGEND FOR CONTROL DIAGRAM1. COMPONENTS AND PANELS SHOWN WITH A ( ) ARE SPECIFIED UNDER SECTION PROCESS 2. COMPONENTS AND PANELS SHOWN WITH A DOUBLEASTERISK (**) ARE PART OF A PACKAGE SYSTEM;GENERAL NOTESINSTRUMENTATION AND CONTROL SYSTEM.SEE EQUIPMENT SPECIFICATIONS.ABBREVIATIONS & LETTER SYMBOLSRELAY, COMPUTE, CONVERTINTEGRATE OR TOTALIZEDRIVE, ACTUATOR, UNCLASSIFIEDSWITCH OR SAFETYMULTIFUNCTION (+)VALVE, DAMPER, LOUVERUNCLASSIFIED (+)FINAL CONTROL ELEMENTOPEN ORIFICE, TEST RESTRICTIONZ-AXISY-AXISX-AXISSAFETYINTEGRATE, TOTALIZEWELLUNCLASSIFIED (+)RECORD MULTIFUNCTION (+)TRANSMITPNEUMATICSTOPSTARTUNCLASSIFIED (+)DI/DOOVERLOADMULTIFUNCTION (+)AIDIAIDI/DODI/AIDODOOPEN-START-INCREASECONTROL STATIONCONTROL OR CONTROLLEROUTPUT FUNCTIONCLOSE-STOP-DECREASEINSTRUMENT SOCIETY OF AMERICA TABLEMOMENTARYTIME RATE OF CHANGESCANRATIO/FRACTIONDIFFERENTIALMODIFIERINDICATEOPEN OR OPERATELIGHT SENSOR, PRIMARY ELEMENTGLASS VIEWING DEVICESUCCEEDING LETTERSPASSIVE FUNCTIONCLOSEALARMREADOUT ORDO/AOI/O TYPESH-HIGH ALARM HH-HIGH HIGHL-LOW ALARM LL-LOW LOWMIDDLE, INTERMEDIATEFAILAIDIDIDO/AIDIDIMODIFIERDODODI/AODIFFEEDER CABLETHIRD QUADRANT3QFIRST AND SECOND QUADRANTSFOURTH QUADRANTNETWORK CABLE4 DIGITAL, DISCRETE OUTPUTS4 DIGITAL, DISCRETE INPUTSTHIRD AND FOURTH QUADRANTSLIMEALUMCHLORINENLiAlCl3Q-4Q4/DO4/DI1Q-2Q4QFIRST QUADRANTSWITCH AND PILOTS LIGHTMANUAL CONTROLS SELECTORHONEYWELL CMC COORDINATEDTEMPERATURE CABLE i.e. RTDFIBER OPTIC CABLESECOND QUADRANTMOTOR CABLEASSEMBLIES1Q2QCMCTOMHAND SWITCHHSFILTRATION, LOOP 1LIMIT SWITCH STATUS LIGHTOPEN, CLOSE, FULLDIGITAL CABLE i.e. DATA HIGHWAYCONTROL CABLEANALOG DATA CABLETERMINAL STRIPJUNCTION BOXPILOT LIGHT, HARDWIREDOPEN, CLOSE, AUTO, RESETQL ADCTSJBDIZLOCFOCARXXXXSCADA, FLOW INDICATORCONTROLLER, ACCESSIBLESCADA/PLC/DCS, DIGITALPROCESSOR, ALARMS, SET POINTS,ETC. ACCESSIBLESCADA/PLC/DCS, DIGITALPROCESSOR, ALARMS, SETPOINTS, ETC. NON-ACCESSIBLEPLC/DCS COMPUTATION,ACCESSIBLEHAND SWITCH, MAINCONTROL PANEL (MCP)HAND SWITCH, MOTORCONTROL CENTERPID FLOW CONTROLLER, MAINCONTROL PANEL (MCP)PID FLOW CONTROLLER, MOTORCONTROL CENTERFIELD MOUNTED INSTRUMENT,TRANSMITTER, SWITCHPANEL MOUNTED DISPLAY,INDICATOR, CONTROLVARIABLE FREQUENCY DRIVE"ON" TIME DELAYB "ON" X-SEC. AFTERA "ON".INSTANT "OFF".OFF" TIME DELAYB "OFF" X-SEC. AFTER A"OFF".INSTANT "ON".SIGNAL INTEGRATOR ORINTERLOCK. SEECONTROL DIAGRAMSMEMORY ELEMENT S=SET,R=RESETSWITCHING SIGNALON/OFF RELAY, INPUT ISCONNECTED TO OUTPUTWHEN SWITCHING SIGNAL ISPRESENT.SWITCHING SIGNALSWITCHING RELAY, INPUT WITHDOT IS CONNECTED TO OUTPUTWHEN SWITCHING SIGNAL ISPRESENT.OTHER OUTPUT IS CONNECTEDTO OUTPUT WHEN SWITCHINGSIGNAL IS NOT PRESENT.LINESINSTRUMENTATION LINESNUMBER INDICATES THE NUMBER OFPARALLELING LINES (PARENTHETICALSIGNALS REPRESENTED)CONNECTING LINESNON-CONNECTING(4)(8)(3)ANALOGDISCRETE/POWER SIGNALDIGITAL(ON,OFF,ETC.)CAPILLARYHYDRAULICPNEUMATICELECTRIC POWERDATA LINKKFLOOR DRAINGENERAL NOTESEQUIPMENT/VALVE DESIGNATIONACATSB BOSCC CD CFS CP DFN SDG SLG DSEMEXF GEN GDR HFOTSSB SRSSWMTC UVHC VEF VSFMCCMCS MH SUP NPSWMBFVBLVCKVDIV HSVGLV GTV MDV PLV SCVPSVAIR COMPRESSORAUTOMATIC TRANSFER SWITCHBASIN (CONCRETE)BLOWOFF SILENCERCALIBRATION COLUMNCONTROL DAMPERCHEMICAL FEED PUMP SKIDCONTROL PANELDUCT FURNACESLIDE GATESLUICE GATEDIVERSION STRUCTUREEMERGENCY EYEWASHEXHAUST FANSTANDYBY GENERATORGRINDERHARMONIC FILTEROUTLET SILENCERSPLITTER BOXSEPTAGE RECIEVING STATIONSEAL WATER MONITORTURBO COMPRESSORUV HYDRAULIC SYSTEM CENTERVENTILATION EXHAUST FANVENTILATION SUPPLY FANMOTOR CONTROL CENTERMOTOR CONTROL SILENCERMANHOLESUMP PUMPNON-POTABLE WATER PUMP STATIONWATER METERBUTTERFLY VALVEBALL VALVECHECK VALVEDIAPHRAGM VALVEHOSE VALVEGLOBE VALVEGATE VALVEMUD VALVEPLUG VALVESCREW CONVEYORPRESSURE SUSTAINING VALVEGFERVENERGY RECOVERY VENTILATORGREASE FILTERPULSATION DAMPENERINSTRUMENTATION BIOREACTOR PANELINLET FILTERHOT WATER HEATERINLET SILENCERINTERNALLY-FED DRUM SCREENLOCAL OPERATOR STATIONPDIBPINFHWHINSIDSLOSODOR CONTROL SYSTEMOCSPUMPPSUBMERSIBLE MIXERSMSTOP GATESTGSCREENINGS WASHER/COMPACTORSWCUV DISINFECTION BANKUVBUV POWER DISTRIBUTION CENTERUVPDTANK (PLASTIC/METAL)TBACKFLOW PREVENTION VALVEBPVKNIFE GATE VALVEKGVPRESSURE CONTROL VALVEPCVPRESSURE RELIEF VALVEPRVSOLENOID VALVESOVAIR RELEASE VALVEARVACVAIR/VACUUM COMBINATION VALVEVARIABLE FREQUENCY DRIVEVFDRTROCK TRAPYHYARD HYDRANTMCXX-MC-ZZINSTRUMENT IDENTIFICATIONPRESSURE DIFFERENTIAL-ELEMENT/INDICATE/SWITCH (HIGH/LOW)PRESSURE ELEMENTPRESSURE TRANSMITTER AND INDICATORPRESSURE SWITCH - HIGH/LOWPRESSURE TRANSMITSPEED CONTROL-VAIRABLE FREQUENCY DRIVESPEED ELEMENTSPEED SWITCHSEAL WATER MONITORTEMPERATURE ELEMENTTEMPERATURE TRANSMITTER AND INDICATORTEMPERATURE SWITCH - HIGH/LOWALARM POWEREVENT LIGHTPOSITION SWITCHXX-NS-ZZNSXX-PDX-ZZPDXXXX-PE-ZZPEXX-PIT-ZZPITXX-PSX-ZZPSXXX-PT-ZZPTXX-SC-ZZSCXX-SE-ZZSEZSXX-ZS-ZZYLXX-YL-ZZXAXX-XA-ZZTSXXX-TSX-ZZSWMXX-SWM-ZZXX-SS-ZZSSTM°FMHEAT EXCHANGERSILENCERHOT WATER HEATERKNIFEFILTERTEMPERATUREGAUGEFLOW METERPROBEDO = DISSOLVED OXYGENNH4= AMMONIUMPH = PHNOX= NITRATECONTROL DAMPERNATURAL GAS HEAT COILSCREENINGSWASHER/COMPACTORSCREW CONVEYORINTERNALLY-FEDGRINDEREXHAUST FANCOMPRESSED AIR TANKDRUM SCREENREDUCERBACKFLOW PREVENTIONOUTSIDE AIR DAMPERANNUNCIATORTRENCH DRAINVALVEEQUIPMENT NUMBERS100 =200 = 300 = 400 = 500 = 600 = 700 = 800 = INFLUENT PUMP STATIONHEADWORKSSEQUENCING BATCH REACTORUV DISINFECTION NPW PUMPING SYSTEMEFFLUENTAEROBIC DIGESTIONSOLIDS HANDLINGXX-YYY-ZZGROUP DESIGNATIONEQUIPMENT/PROCESS DESIGNATIONNUMERICAL DESIGNATIONGROUP DESIGNATIONLSXXX-LSX-ZZLOSXX-LOS-ZZLITXX-LIT-ZZLEXX-LE-ZZLAXXX-LA-ZZJIXX-JI-ZZHSXX-HS-ZZANALYTICAL ELEMENT (PROBE)- DO/NH4/NOX/PH/LEL/H2SANALYTICAL TRANSMITTER AND INDICATORALARM LIGHTEMERGENCY SWITCHFLOW ELEMENTFLOW TRANSMITTER AND INDICATORHAND SWITCHPOWER INDICATELEVEL ALARM - HIGH/LOWLEVEL ELEMENTLEVEL TRANSMITTER AND INDICATORLOCAL OPERATOR STATIONLEVEL SWITCH - HIGH/LOWMOTOR CONTROL-FULL VOLTAGE NON REVERSINGMOISTURE SWITCHFITXX-FIT-ZZFEXX-FE-ZZESXX-ES-ZZALXX-AL-ZZXX-AIT-ZZAITLEGEND.INTAKE DUCTSILENT CHECKXX-AE-ZZAE900 = CHEMICAL FEED1000 = GENERATORWYE-STRAINERWSMDMOTORIZED DAMPERVFDTEXX-TE-ZZTITXX-TIT-ZZASSOCIATEDDEVICES1.THIS IS A STANDARD LEGEND,THEREFORE, NOT ALL OF THISINFORMATION MAY BE USED ONTHIS PROJECT.2.SEE ELECTRICAL LEGEND FORCONTROL DIAGRAM LEGEND.TVTELESCOPING VALVEVERIFY SCALE!THESE PRINTS MAY BE REDUCED.LINE BELOW MEASURES ONE INCHON ORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY!2025COPYRIGHT © MORRISON-MAIERLE,SHEET NUMBERPROJECT NUMBERDRAWING NUMBERDATEDESCRIPTIONNO.BYP:\10678-LAUREL PARKWAY LLC\001 - NORTON RANCH LIFT STATION\ACAD\SHEETS\0-GENERAL\G-6_P&ID_LEGENDS&NOTES.DWGREVISIONS DRAWN BY:DSGN. BY:APPR. BY:DATE:Q.C. REVIEWDATE:BY:2880 Technology Blvd WestBozeman, MT 59718406.587.0721www.m-m.netengineers surveyors planners scientistsMorrisonMaierlePLOTTED BY:LEE HAGEMAN ON Jun/04/2025 NORTON RANCH LIFT STATION UPGRADES BOZEMANMONTANAP&ID LEGEND AND NOTES10678.0017G-7KJSLRHLRH06/2025 AGENCY REVIEW (REVISION 2)JUNE 202505/29/2025