HomeMy WebLinkAbout006 - G-6 - ELECTRICAL LGNDS & SMBLS O�20A OR �1100AF LOW-VOLTAGE CIRCUIT BREAKER(CB). """�PT CONTROL POWER TRANSFORMER(CPT) pQp NORMALLY CLOSED LIMIT SWITCH, $Y TOGGLE SWITCH OX HEAT DETECTOR LP-� ALARM FLASHING LIGHT
80AT RATINGS AND NO.OF POLES AS SHOWN. OPEN ON REACHING LIMIT �-(�
O 3P O�3p WHEN SPECIFIC NPE IS REQUIRED,X INDICATES SUBSCRIPTS: SUBSCRIPT: �X� ALARM BELLAND FLASHING
TYPE. X-INDICATESTYPE �-f•'� LIGHTCOMBINATIONUNIT
� � RELD WIRING EXTERNAL TO CONTROL PANEL R/C-RATE COMPENSATION
NONE-SINGLE POLE RIF-COMBINATION RATE OF � ALARM HORN AND FLASHING
TYPES: VOLTAGE TRANSFORMER(VT OR PT) /\ X
�x� INTERLOCK;X INDICATES TYPE 3-THREE-WAY RISE AND FIXED TEMP LIGHT COMBINATION UNIT
MCCB-MOLDED CASE �� 4-FOUR-WAY R-RATE OF RISE
ICCB-INSULATED CASE TYPES: HP-TOGGLE SWITCH,HORSEPOWER RATED F-FIXED SUBSCRIPT:
LVP-LOW-VOLTAGE POWER � CURRENT TRANSFORMER(CT) K-KEY SWITCH
MCP-MOTOR CIRCUIT PROTECTOR E-ELECTRICAL M- NONE-GENERAL ALARM DEVICE
(RATING PER CONNECTED LOAD) OFF KEY HANICAL K- pE pILOT L GHTOTOR STARTER WITH THERMAL ELEMENT � ALARM BELL F-FIRE ALARM DEVICE
L-LIGHTED HANDLE
CB SEPARATELY MOUNTED CIRCUIT BREAKER;SEE O HAND � AUTO Y-SWITCH NAMEI�ESIGNATION X ALARM HORN
WH UTILITY WATT-HOUR METER PER UTILITY �/� XOO 3 POSITION SELECTOR SWITCH,MAINTAINED CONTACTS;
ELECTRICAL ONE-LINE DIAGRAM OR SCHEDULE FOR REQUIREMENTS
DESCRIPTION UNLESS OTHERWISE NOTED,2-POSITION SIMILAR SPECIAL-PURPOSE RECEPTACLE AS DEFWED ON PLANS
� oox � ABBREVIATIONS:
GFP GROUNDFAULTPROTECTION � -� AorAMP AMPERES
DMP DIGITAL METERWG PACKAGE PLUG-IN RECEPTACLE STRIP,QUANTITYAND SPACING OF
� NORMALLY OPEN PUSHBUTTON,MOMENTARY � AC ALTERNATING CURRENT
O O RECEPTACLES AS NOTED OR SPECIFIED
SZ CONTACT UNLESS OTHERWISE NOTED ATS AUTOMATIC TRANSFER SWITCH
MEDIUM-VOLTAGE CIRCUIT BREAKER ETM ELAPSED TIME METER
o I n NORMALLY CLOSED PUSHBUTTON,MOMENTARY N TELECOMMUNICATIONS OUTLET JUNCTION BOX C CONDUIT
CONTACT UNLESS OTHERWISE NOTED CB CIRCUIT BREAKER
� FUSE,SIZE,AN�NUMBER OF FUSES AS NOTED �X
T X INDICATING LIGHT,X INDICATES LENS COLOR QUAD-DUPLEX RECEPTACLE,TWO NEMA 5-20R CKT CIRCUIT
� _ GROUND Y UNDER COMMON COVER PLATE
FUSED CUTOUT,CURRENT RATING,FUSE SIZE,AND CU COPPER
NUMBER OF POLES AS NOTED I �.,q X
�, Y�� PUSH TO TEST INDICATING LIGHT,X INDICATES LENS �yY DUPLEX RECEPTACLE,NEMA 5-20R EF EXHAUST FAN
- -y� FUSIBLE SWITCH,CURRENT RATING,FUSE SIZE,AND b �0���� COLOR ELEC ELECTRIC
- LIGHTNING ARRESTER �X EMT ELECTRICAL METALLIC TUBING
�UANTITY AS NOTED LENS COLORS:
— SIMPLEX RECEPTACLE,NEMA 5-20R EXP EXPLOSION PROOF
R-RED Y-YELLOW W Y
� NON-FUSED SWITCH,CURRENT RATING,AND SPp LOW VOLTAGE SURGE PROTECTIVE DEVICE
NUMBER OF POLES AS NOTED � G-GREEN -WHITE A- SUBSCRIPTS: GFI GROUND FAULT INTERRUPTER
B-BLUE AMBER X-INDICATESTYPE GND GROUND
GFCI-GROUND FAULT CIRCUIT INTERRUPTER
^ DISCONNECT OR DRAWOUT CONNECTION ELECTRICAL CONNECTION �T TRANSFORMER Y-INDICATES CIRCUIT NUMBER FROM PANELBOARD HOA HAND-OFF-AUTOMATIC
MAGNETIC MOTOR STARTER AND HP HORSEPOWER
SS SELECTOR SWITCH
A o � A c� SEPARATELY MOUNTE�COMBINATION MAGNETIC � CONDUIT TURNING UP HVAC HEATING,VENTILATING&
B B MOTOR STARTER � OR� OR — NO ELECTRICAL CONNECTION PB AIR CONDITIONING
PUSHBUTTON � CONDUITTURNINGDOWN HZ HERTZ
MOTOR CONTROLLER AND A IC INSTRUMENTATION/CONTROL DEVICE J-BOX JUNCTION BOX
D U & D ❑ SEPARATELY MOUNTED MOTOR CONTROLLER WITH SV OR O--'I�--O SOLENOID VALVE ��` HOME RUN TO PANEL,2#12,1#12G IN 3/4"C UNLE55
SHORT CIRCUIT PROTECTION AND DISCONNECT � � OTHERWISE NOTED
CONTROL PANEL INTEGRAL OR PROVIDED WITH ASSOCIATED kW KILOWATTS
MOTOR STARTER AND CONTROLLER SUBSCRIPTS: X EQUIPMENT kVA KILOVOLT AMPERES
CONTROLIRELAY COIL;X INDICATES TYPE, HOME RUN WITH CONDUIT SEAL-OFF
A-MAGNETIC STARTER NEMA SIZE Y Y INDICATES LOOP NO.WHEN USED CONTROL PANEL WITH DISCONNECT SWITCH INTEGRAL OR �_� LFMC LIQUIDTIGHT FLEXIBLE METAL CONDUIT
B-STARTERTYPE TVPES: � PROVIDEDWITHASSOCIATEDEQUIPMENT
CR-CONTROL RELAY CIRCUIT RUN BETWEEN DEVICES EXPOSED IN MAN MANUAL
NONE-FULL VOLTAGE NON-REVERSING(FVNR) JQ JUNCTION OR PULL BOX NON-ARCHITECTURALLY FINISHED AREAS; MCC MOTOR CONTROL CENTER
FVR-FULL VOLTAGE REVERSING DP-DEFINITE PURPOSE RELAY CONCEALED IN ARCHITECTURALLY FINISHED AREAS. MECH MECHANICAL
2S-TWO SPEED LC-LIGHTING CONTACTOR
RVAT-REDUCED VOLTAGE AUTO TRANSFORMER M-MOTOR STARTER _ PANELBOARD(250V TO 600V) CONDUIT AND CONDUCTOR SIZES SHALL BE THE MFR MANUFACTURER
PC-PHOTO CELL SAME AS THE HOMERUN FOR THE CIRCUIT.
C-CONTROL DIAGRAM OR CONTROLS TC-TIME CLOCK N NEUTRAL
SCHEDULE NUMBER(IF REQUIRED) TR-TIMING RELAY � PANELBOARD(LESS THAN 250V) - - - CONDUIT RUN BETWEEN DEVICES CONCEALED IN NC NORMALLY CLOSED
NON-ARCHITECTURALLY RNISHED AREAS OR UNDER NEC NATIONAL ELECTRICAL CODE
D-CONTROLLER TYPE �� NORMALLY OPEN CONTACT(N.O.) NO NORMALLY OPEN
VFD-VARIABLE FREQUENCY DRIVE ELECTRICAL EQUIPMENT ENCLOSURE:SWITCHBOARD,MOTOR FLOOR SLAB.CONDUIT AND CONDUCTOR SIZES
CONTROL CENTER,CONTROL PANEL,OR OTHER EQUIPMENT A SHALL 8E THE SAME AS THE HOMERUN FOR THE # NUMBER
SS-SOLID STATE �� NORMALLY CLOSED CONTACT(N.C.) INDICATED CIRCUIT.
� PB PUSHBUTTON
SEPARATELY MOUNTED COMBINATION MOTOR p� p NORMALLY OPEN TIME DELAY RELAY CONTACT WITH CIRCUIT HASH MARKS(WHEN INDICATED);LONG, pH PHASE
STARTER OR CONTROLLER;SEE ELECTRICAL l� TIME DELAY ON CLOSING AFTER COIL IS ENERGIZED OD MOTION DETECTOR,PROVIDE POWER PACK AS NEEDED �— SHORT,SINGLE DOT,AND DOUBLE DOT REPRESENT PNL PANEL
ONE-LWE DIAGRAM OR SCHEDULE FOR �`� PHASE,NEUTRAL,EQUIPMENT GROUND,AND PVC POLYVINYL CHLORIDE CONDUIT
DESCRIPTION O ISOLATED EQUIPMENT GROUND,RESPECTIVELY.#12 PWR POWER
� NORMALLY CLOSED TIME DELAY RELAY CONTACT PC PHOTOCELL IN 3/4"CONDUIT UNLE55 OTHERWISE INDICATED.
WITH TIME DELAY ON OPENING AFTER COIL IS
THERMALOVERLOADELEMENT X RECPT RECEPTACLE
ENERGIZED y� �() CEILING/PENDANT-MOUNTEDLUMINAIRE-HID, � CIRCUITCONTINUATION RGS RIGIDGALVANIZEDSTEEL
OL ,� „ NORMALLY OPEN TIME DELAY RELAY CONTACT WITH M Y COMPACT RUORESCENT,OR INCANDESCENT
� THERMAL OVERLOAD RELAY CONTACT ��I � TIME DELAY ON OPENING AFTER COIL IS � CONDUIT STUBBED OUT AND CAPPED SV SOLENOID VAWE
W\ DE-ENERGIZED �x WALL-MOUNTED LUMINAIRE-HID,COMPACT SW SWITCH
��-4 Y FLUORESCENT,OR WCANDESCENT SWBD SWITCHBOARD
� NORMALLY CLOSED TIME DELAY RELAY CONTACT XXX CONDUIT TAG OR CIRCUIT NUMBER-WIRE AND
DISCONNECT OR SAFETY SWITCH,30A,3P, � SWGR SWITCHGEAR
NON-FUSED UNLESS OTHERWISE NOTED WITH TIME DELAY ON CLOSING AFTER COIL IS z X CONDUIT SIZE AS SPECIFIED IN CIRCUIT SCHEDULE
c� DE-ENERGIZED z O CEILING/PENDANT-MOUNTED FLUORESCENT FIXTURE ON THE SHEETS
� Y T THERMOSTAT
� O NORMALLY OPEN TEMPERATURE SWITCH; X TD TIME DELAY
° 7 1I2 OR HP � CLOSE ON RISWG TEMPERATURE �y �NALL-MOUNTE�FLUORESCENT FIXTURE GROUND CABLE TEL TELEPHONE
� MOTOR WITH DESIGN HORSEPOWER
(WHEN INDICATED) � �X CEILINGIPENDANT-MOUNTED RUORESCENT RXTURE O UG UNDERGROUND
NORMALLY CLOSED TEMPERATURE SWITCH; z Y GROUND ROD
OPEN ON RISING TEMPERATURE NORMAUEMERGENCY UH UNIT HEATER
w
X WALL-MOUNTED FLUORESCENT FIXTURE FAA RRE ALARM ANNUNCIATOR V VOLT
J O�O �y NORMAUEMERGENCY VA VOLTAMPERES
= �� NORMALLY OPEN FLOW SWITCH;
CLOSE ON INCREASING FLOW FACP FIRE ALARM WNTROL PANEL VFD VARIABLE FREQUENCY DRIVE
`� G GENERATOR �X EMERGENCY LIGHT FIXTURE,2 ATTACHED HEADS AS
w SHOWN
NORMALLY CLOSED FLOW SWITCH; Y W WATTS
W TRANSFER SWITCH,CURRENT RATING,AND � OPEN ON INCREASING FLOW X � RRE ALARM MANUAL PULL STATION WP WEATHERPROOF GENERAL NOTES:
c� O p = EMERGENCY LIGHT,REMOTE MOUNTED HEAD
NUMBER OF POLES AS NOTED Y 1.THIS IS A STANDARD ELECTRICAL SYMBOLOGY
� / �o XFMR TRANSFORMER
6 Tg ATS-AUTOMATIC f\� NORMALLY OPEN LEVEL SWITCH,
c� MTS-MANUAL �J CLOSE ON RISING LEVEL �X �X DOUBLE-FACED CEILING OR WALL-MOUNTED EXIT �R RRE ALARM CONTROL RELAY SHEET.NOT ALL
LIGHT;DIRECTIONAL ARROWS(IF REQUIRED)AS Y WYE CONNECTED SYMBOLS MAY BE USED ON THIS PROJECT.
, � � Y f Y INDICATED ON PLANS FS FIRE ALARM CONTACT,FLOW SWITCH
w NORMALLY CLOSED LEVEL SWITCH, 2 SCREENING OR SHADING OF WORK IS USED
DELTA CONNECTED
� �Y'�'Y'� TRANSFORMER OPEN ON RISING LEVEL X X SINGLE-FACED CEILING OR WALL-MOUNTED EXIT TO INDICATE EXISTING
� I'�} LIGHT;DIRECTIONAL ARROWS QF REQUIRED)AS TS FIRE ALARM CONTACT,TAMPER SWITCH COMPONENTS OR TO DE-EMPHASIZE PROPOSED
� I � 3-PHASE,3-WIRE DELTA CONNECTION � NORMALLY OPEN PRESSURE SWITCH, Y Y INDICATED ON PLANS � PHASE IMPROVEMENTS
z � PS FIRE ALARM CONTACT,PRESSURE SWITCH TO HIGHLIGHT SELECTED TRADE WORK.REFER
CLOSE ON INCREASING PRESSURE
4 `(; 3-PHASE,4-WIRE GROUNDED WYE X TO CONTEXT OF EACH
< CONNECTION � NORMALLY CLOSED PRESSURE SWITCH, �"� AREA OR ROADWAY LIGHT-POLE-MOUNTED SHEET FOR USAGE.
`� OPEN ON INCREASING PRESSURE Y
LIGHTING FIXTURE SUBSCRIPTS: OX AND � X SMOKE AND DUCT DETECTOR 3. REFERENCES OTHER LEGEND SHEETS FOR
SWITCHBOARD OR PANELBOARD;NAME,VOLTAGE, SUBSCRIPT. PROJECT-SPECIFIC EQUIPMENT
zPHASE,NUMBER OF WIRES WHEN INDICATED X-INDICATES FIXTURE TYPE PER LIGHTING
� � NORMALLY CLOSED PRESSURE SWITCH, FIXTURE SCHEDULE SYMBOLS,EQUIPMENTABBREVIATIONS,AND
OPEN ON INCREASING PRESSURE I-IONIZATION TYPE PIPING SYSTEM ABBREVIATIONS.
Y-INDICATES CIRCUIT NUMBER FROM PANELBOARD P-PHOTOELECTRIC TYPE
° z-INDICATES CONTROLLING SWITCH QF REQUIRED) �]
0 100 �� NORMALLYOPENLIMITSWITCH, AGENCY REVIEW (REVISION L)
KVA NON-MOTOR LOAD WITH DESIGN KVA,KW,OR AMP CLOSE ON REACHING LIMIT
m MANUALMOTORSTARTER
JUNE 2025
J REVISIONS
J veaiFv SCn�e�. DRAWN BY: KJS PROJECT NUMBER
� _,al�'�A�J �>>
NO. DESCRIPTION BY DATE y' --C�` � �� 10678.001
mesePrzmrsnnnvserzeouceo. MOI �ISO� � 2880TechnologyBlvdWest DSGN.BY: LRH NORTONRANCHLIFTSTATIONUPGRADES
a LINE BELOW MEASURES ONE INCH ■■ �^� ����
oN orziciNn�oanwiNc. � Bozeman,MT 59718 , qppR.BY: LRH SHEET NUMBER
,� BOZEMAN MONTANA 6
�--F � M a i e r I e 406 58�0�2, �A W.
� No.48 6 PE=J DATE: O6/2025 DRAWWG NUMBER
�'r� q o/zv/zozs
MooiFvscn�enccoaowc�v� � www.m-m.net ��ssp��57EREo�G� q.C.REVIEW ELECTRICALLEGENDSANDSYMBOLS G��
engineers surveyors planners scientists ��'4�ONAL`�` BY�
a PLOTTED BV:LEE HAGEMAN ON JUN04/2025 COPVRiGHT�OMORRISON-MAIERLE,2025 DATE: