Loading...
HomeMy WebLinkAbout006 - G-6 - ELECTRICAL LGNDS & SMBLSXXXSJXXXYX100KVASPDWHDMPETMORORSVORCPT3Ø, 4W208/120VLP100ATSOLBDDCD CABCA7 1/2HPG52GFPCBANDCONDUIT RUN BETWEEN DEVICES CONCEALED INNON-ARCHITECTURALLY FINISHED AREAS OR UNDERFLOOR SLAB. CONDUIT AND CONDUCTOR SIZESSHALL BE THE SAME AS THE HOMERUN FOR THECIRCUIT.CRFIRE ALARM CONTROL RELAYGENERAL NOTES:1. THIS IS A STANDARD ELECTRICAL SYMBOLOGYSHEET. NOT ALL SYMBOLS MAY BE USED ON THIS PROJECT.2.SCREENING OR SHADING OF WORK IS USEDTO INDICATE EXISTING COMPONENTS OR TO DE-EMPHASIZE PROPOSEDIMPROVEMENTS TO HIGHLIGHT SELECTED TRADE WORK. REFERTO CONTEXT OF EACH SHEET FOR USAGE.3.REFERENCES OTHER LEGEND SHEETS FORPROJECT-SPECIFIC EQUIPMENT SYMBOLS, EQUIPMENT ABBREVIATIONS, ANDPIPING SYSTEM ABBREVIATIONS.ELECTRICAL CONNECTIONNO ELECTRICAL CONNECTIONCURRENT TRANSFORMER (CT)VOLTAGE TRANSFORMER (VT OR PT)UTILITY WATT-HOUR METER PER UTILITYREQUIREMENTSNORMALLY OPEN TIME DELAY RELAY CONTACT WITHTIME DELAY ON CLOSING AFTER COIL IS ENERGIZEDNORMALLY CLOSED TIME DELAY RELAY CONTACTWITH TIME DELAY ON OPENING AFTER COIL ISENERGIZEDNORMALLY OPEN TIME DELAY RELAY CONTACT WITHTIME DELAY ON OPENING AFTER COIL ISDE-ENERGIZEDNORMALLY CLOSED TIME DELAY RELAY CONTACTWITH TIME DELAY ON CLOSING AFTER COIL ISDE-ENERGIZEDSOLENOID VALVECONTROL/RELAY COIL; X INDICATES TYPE,Y INDICATES LOOP NO. WHEN USEDTYPES:CONTROL POWER TRANSFORMER (CPT)NORMALLY OPEN CONTACT (N.O.)NORMALLY CLOSED CONTACT (N.C.)NORMALLY OPEN TEMPERATURE SWITCH;CLOSE ON RISING TEMPERATURENORMALLY CLOSED TEMPERATURE SWITCH;OPEN ON RISING TEMPERATURENORMALLY OPEN FLOW SWITCH;CLOSE ON INCREASING FLOWNORMALLY CLOSED FLOW SWITCH;OPEN ON INCREASING FLOWNORMALLY CLOSED PRESSURE SWITCH,OPEN ON INCREASING PRESSURENORMALLY OPEN LIMIT SWITCH,CLOSE ON REACHING LIMITNORMALLY CLOSED LIMIT SWITCH,OPEN ON REACHING LIMITGROUNDLIGHTNING ARRESTERDIGITAL METERING PACKAGEELAPSED TIME METERLOW VOLTAGE SURGE PROTECTIVE DEVICE&CONTROL PANEL WITH DISCONNECT SWITCH INTEGRAL ORPROVIDED WITH ASSOCIATED EQUIPMENTMOTOR CONTROLLER ANDSEPARATELY MOUNTED MOTOR CONTROLLER WITHSHORT CIRCUIT PROTECTION AND DISCONNECT&QUAD-DUPLEX RECEPTACLE, TWO NEMA 5-20RUNDER COMMON COVER PLATEXYTELECOMMUNICATIONS OUTLET JUNCTION BOXPLUG-IN RECEPTACLE STRIP, QUANTITY AND SPACING OFRECEPTACLES AS NOTED OR SPECIFIEDFIELD WIRING EXTERNAL TO CONTROL PANELPHOTOCELLPCSWITCHBOARD OR PANELBOARD; NAME, VOLTAGE,PHASE, NUMBER OF WIRES WHEN INDICATEDzSUBSCRIPT:SUBSCRIPT:HEAT DETECTORXFAAFIRE ALARM ANNUNCIATORCONDUIT TAG OR CIRCUIT NUMBER - WIRE ANDCONDUIT SIZE AS SPECIFIED IN CIRCUIT SCHEDULEON THE SHEETSCONDUIT STUBBED OUT AND CAPPEDCIRCUIT CONTINUATIONELECTRICAL EQUIPMENT ENCLOSURE: SWITCHBOARD, MOTORCONTROL CENTER, CONTROL PANEL, OR OTHER EQUIPMENT ASINDICATEDWALL-MOUNTED FLUORESCENT FIXTURENORMAL/EMERGENCYXYzNON-MOTOR LOAD WITH DESIGN KVA, KW, OR AMPSIMPLEX RECEPTACLE, NEMA 5-20RXYXYzYXSEPARATELY MOUNTED COMBINATION MOTORSTARTER OR CONTROLLER; SEE ELECTRICALONE - LINE DIAGRAM OR SCHEDULE FORDESCRIPTIONNON-FUSED SWITCH, CURRENT RATING, ANDNUMBER OF POLES AS NOTED3P20AXMCCB - MOLDED CASEICCB - INSULATED CASELVP - LOW - VOLTAGE POWERMCP - MOTOR CIRCUIT PROTECTOR (RATING PER CONNECTED LOAD)3P80AT100AFxPSFIRE ALARM CONTACT, PRESSURE SWITCHTSFIRE ALARM CONTACT, TAMPER SWITCHFIRE ALARM CONTACT, FLOW SWITCHFSGROUND RODGROUND CABLEXSUBSCRIPT:XSMOKE AND DUCT DETECTORXALARM HORN AND FLASHINGLIGHT COMBINATION UNITXALARM BELL AND FLASHINGLIGHT COMBINATION UNITXALARM FLASHING LIGHTXALARM HORNXALARM BELLFIRE ALARM MANUAL PULL STATIONFFIRE ALARM CONTROL PANELFACPSUBSCRIPTS:YXSPECIAL-PURPOSE RECEPTACLE AS DEFINED ON PLANSDUPLEX RECEPTACLE, NEMA 5-20RSUBSCRIPTS:TOGGLE SWITCHLIGHTING FIXTURE SUBSCRIPTS:AREA OR ROADWAY LIGHT - POLE-MOUNTEDYXYXYXSINGLE-FACED CEILING OR WALL-MOUNTED EXITLIGHT; DIRECTIONAL ARROWS (IF REQUIRED) ASINDICATED ON PLANSDOUBLE-FACED CEILING OR WALL-MOUNTED EXITLIGHT; DIRECTIONAL ARROWS (IF REQUIRED) ASINDICATED ON PLANSXYXYEMERGENCY LIGHT, REMOTE MOUNTED HEADXYEMERGENCY LIGHT FIXTURE, 2 ATTACHED HEADS ASSHOWNCEILING/PENDANT-MOUNTED FLUORESCENT FIXTURENORMAL/EMERGENCYYXzWALL-MOUNTED FLUORESCENT FIXTURECEILING/PENDANT-MOUNTED FLUORESCENT FIXTUREYXzWALL-MOUNTED LUMINAIRE - HID, COMPACTFLUORESCENT, OR INCANDESCENTXYzCEILING/PENDANT-MOUNTED LUMINAIRE - HID,COMPACT FLUORESCENT, OR INCANDESCENTXYzCIRCUIT HASH MARKS (WHEN INDICATED); LONG,SHORT, SINGLE DOT, AND DOUBLE DOT REPRESENTPHASE, NEUTRAL, EQUIPMENT GROUND, ANDISOLATED EQUIPMENT GROUND, RESPECTIVELY. #12IN 3/4" CONDUIT UNLESS OTHERWISE INDICATED.GROUND FAULT PROTECTIONLENS COLORS:CIRCUIT RUN BETWEEN DEVICES EXPOSED INNON-ARCHITECTURALLY FINISHED AREAS;CONCEALED IN ARCHITECTURALLY FINISHED AREAS.CONDUIT AND CONDUCTOR SIZES SHALL BE THESAME AS THE HOMERUN FOR THE CIRCUIT.HOME RUN TO PANEL, 2 #12, 1 #12G IN 3/4"C UNLESSOTHERWISE NOTEDCONDUIT TURNING DOWNCONDUIT TURNING UPPANELBOARD (LESS THAN 250V)PANELBOARD (250V TO 600V)TYPES:INTERLOCK; X INDICATES TYPEJUNCTION OR PULL BOXCONTROL PANEL INTEGRAL OR PROVIDED WITH ASSOCIATEDEQUIPMENTICINSTRUMENTATION/CONTROL DEVICEPBPUSHBUTTONSELECTOR SWITCHSSPUSH TO TEST INDICATING LIGHT, X INDICATES LENSCOLORINDICATING LIGHT, X INDICATES LENS COLORNORMALLY CLOSED PUSHBUTTON, MOMENTARYCONTACT UNLESS OTHERWISE NOTEDNORMALLY OPEN PUSHBUTTON, MOMENTARYCONTACT UNLESS OTHERWISE NOTED3 POSITION SELECTOR SWITCH, MAINTAINED CONTACTS;UNLESS OTHERWISE NOTED, 2-POSITION SIMILAROOXXOOHANDAUTOOFFOR3-PHASE, 4-WIRE GROUNDED WYECONNECTION3-PHASE, 3-WIRE DELTA CONNECTIONTTRANSFORMERTRANSFORMERTRANSFER SWITCH, CURRENT RATING, ANDNUMBER OF POLES AS NOTEDGENERATORMOTOR WITH DESIGN HORSEPOWER(WHEN INDICATED)DISCONNECT OR SAFETY SWITCH, 30A, 3P,NON-FUSED UNLESS OTHERWISE NOTEDMEDIUM - VOLTAGE CIRCUIT BREAKERTHERMAL OVERLOAD ELEMENTFUSIBLE SWITCH, CURRENT RATING, FUSE SIZE, ANDQUANTITY AS NOTEDFUSED CUTOUT, CURRENT RATING, FUSE SIZE, ANDNUMBER OF POLES AS NOTEDFUSE, SIZE, AND NUMBER OF FUSES AS NOTEDORSEPARATELY MOUNTED CIRCUIT BREAKER; SEEELECTRICAL ONE - LINE DIAGRAM OR SCHEDULE FORDESCRIPTIONMOTOR STARTER AND CONTROLLER SUBSCRIPTS:THERMAL OVERLOAD RELAY CONTACTMAGNETIC MOTOR STARTER ANDSEPARATELY MOUNTED COMBINATION MAGNETICMOTOR STARTERLOW - VOLTAGE CIRCUIT BREAKER (CB).RATINGS AND NO. OF POLES AS SHOWN.WHEN SPECIFIC TYPE IS REQUIRED, X INDICATESTYPE.DISCONNECT OR DRAWOUT CONNECTIONYXTYPES:A - MAGNETIC STARTER NEMA SIZEB - STARTER TYPE NONE - FULL VOLTAGE NON-REVERSING (FVNR) FVR - FULL VOLTAGE REVERSING 2S - TWO SPEED RVAT - REDUCED VOLTAGE AUTO TRANSFORMERC - CONTROL DIAGRAM OR CONTROLS SCHEDULE NUMBER (IF REQUIRED)D - CONTROLLER TYPE VFD - VARIABLE FREQUENCY DRIVE SS - SOLID STATEATS - AUTOMATICMTS - MANUALCR - CONTROL RELAYDP - DEFINITE PURPOSE RELAYLC - LIGHTING CONTACTORM - MOTOR STARTERPC - PHOTO CELLTC - TIME CLOCKTR - TIMING RELAYE - ELECTRICAL M -MECHANICAL K -KEYR - REDG - GREENB - BLUEY - YELLOW W- WHITE A -AMBERX - INDICATES FIXTURE TYPE PER LIGHTING FIXTURE SCHEDULEY - INDICATES CIRCUIT NUMBER FROM PANELBOARDz - INDICATES CONTROLLING SWITCH (IF REQUIRED)X - INDICATES TYPENONE - SINGLE POLE3 - THREE-WAY4 - FOUR-WAYHP - TOGGLE SWITCH, HORSEPOWER RATEDK - KEY SWITCHTE - MANUAL MOTOR STARTER WITH THERMAL ELEMENTP - PILOT LIGHTL - LIGHTED HANDLEY - SWITCH NAME/DESIGNATIONX - INDICATES TYPE GFCI - GROUND FAULT CIRCUIT INTERRUPTERY - INDICATES CIRCUIT NUMBER FROM PANELBOARDI - IONIZATION TYPEP - PHOTOELECTRIC TYPER/C - RATE COMPENSATIONR/F - COMBINATION RATE OF RISE AND FIXED TEMPR - RATE OF RISEF - FIXEDNONE - GENERAL ALARM DEVICEF - FIRE ALARM DEVICEHOME RUN WITH CONDUIT SEAL-OFFSMANUAL MOTOR STARTERmA or AMPACATSCCBCKTCUAMPERESALTERNATING CURRENTAUTOMATIC TRANSFER SWITCHCONDUITCIRCUIT BREAKERCIRCUITCOPPEREFELECEMTEXPEXHAUST FANELECTRICELECTRICAL METALLIC TUBINGEXPLOSION PROOFGFIGNDGROUND FAULT INTERRUPTERGROUNDHPHVACHZJ-BOXkWkVAMCCMECHHORSEPOWERHEATING, VENTILATING &HERTZJUNCTION BOXKILOWATTSKILOVOLT AMPERESMOTOR CONTROL CENTERMECHANICAL AIR CONDITIONINGHOAHAND-OFF-AUTOMATICMANUALMANLFMCLIQUIDTIGHT FLEXIBLE METAL CONDUITMFRMANUFACTURERNNCNECNO#PBPHPNLPVCPWRRECPTNEUTRALNORMALLY CLOSEDNATIONAL ELECTRICAL CODENORMALLY OPENNUMBERPUSHBUTTONPHASEPANELPOLYVINYL CHLORIDE CONDUITPOWERRECEPTACLERGSRIGID GALVANIZED STEELSVSWSWBDSWGRSOLENOID VALVESWITCHSWITCHBOARDSWITCHGEARTTDTELUGUHVVAVFDWWPTHERMOSTATTIME DELAYTELEPHONEUNDERGROUNDUNIT HEATERVOLTVOLT AMPERESVARIABLE FREQUENCY DRIVEWATTSWEATHERPROOFYWYE CONNECTEDDELTA CONNECTEDPHASEXFMRTRANSFORMERNORMALLY OPEN LEVEL SWITCH,CLOSE ON RISING LEVELNORMALLY CLOSED LEVEL SWITCH,OPEN ON RISING LEVELNORMALLY OPEN PRESSURE SWITCH,CLOSE ON INCREASING PRESSURENORMALLY CLOSED PRESSURE SWITCH,OPEN ON INCREASING PRESSUREABBREVIATIONS:MOTION DETECTOR, PROVIDE POWER PACK AS NEEDEDDVERIFY SCALE!THESE PRINTS MAY BE REDUCED.LINE BELOW MEASURES ONE INCHON ORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY!2025COPYRIGHT © MORRISON-MAIERLE,SHEET NUMBERPROJECT NUMBERDRAWING NUMBERDATEDESCRIPTIONNO.BYP:\10678-LAUREL PARKWAY LLC\001 - NORTON RANCH LIFT STATION\ACAD\SHEETS\0-GENERAL\G-5_ELECTRICALLEGENDS&SYMBOLS.DWGREVISIONS DRAWN BY:DSGN. BY:APPR. BY:DATE:Q.C. REVIEWDATE:BY:2880 Technology Blvd WestBozeman, MT 59718406.587.0721www.m-m.netengineers surveyors planners scientistsMorrisonMaierlePLOTTED BY:LEE HAGEMAN ON Jun/04/2025 NORTON RANCH LIFT STATION UPGRADES BOZEMANMONTANAELECTRICAL LEGENDS AND SYMBOLS10678.0016G-6KJSLRHLRH06/2025 AGENCY REVIEW (REVISION 2)JUNE 202505/29/2025