Loading...
HomeMy WebLinkAbout038 Sht ES1.1 - RUP-Site Plan-Power to h LIGHT FIXTURE SCHEDULE _ 4""^AN TYPE(XX) CATALOG NUMBER: LAMP: MOUNTING: BALLAST/DRIVER: VOLT: WATT; DESCRIPTION: ELECTRICAL LEGEND s:*,' TWhitlock '�,� W W I--I� POLE MOUNT SITE LIGHT O RECESSED LED WALL FIXTURE 0..E BALCONY MOUNT FIXTURE No. t\I TYPE (D2) HALO: SMD6R-12-930-WH-E 3000K LED SHALLOW ELV DIMMING 120 15 SHALLOW MOUNT RECESSED 6" ROUND DOWNLIGHT. I--K-" O OR PRIOR APPROVED EQUAL 120OLM RECESSED LED DRIVER O DOWNUGHT FIXTURE ,{ N,`jC, 7 m ABBREVIATIONS LLl AC ABOVE COUNTER PB PULL BOX COPYRIGFT ICE:This document W Q LITHONIA LIGHTING: LED 4' LINEAR LED SURFACE MOUNT FIXTURE. PROVIDE AFF ABOVE FINISHED FLOOR GD H.O. INSULA INSULATED GROUND (R) REMOVE AND RELOCATE and the ideasand designs incorporated = G1: CLX-L48-3000LM-SEF-RDL-MVOLT-GZ10- 3000K' SURFACE MOUNT 0-1 OV DIMMING 120 21 HATCHED FIXTURES WITH EMERGENCY BATTERY BACKUP. BKR,CB CIRCUIT BREAKER LTS LIGHTS RCPT RECEPTACLES herein are iven in confidence and shall r , TYPE (Gi) 30K-SOCRI-WH LED DRIVER O A v 2740LM CLNG CEILING MC, MECHANICAL TGB TELECOMMUNICATIONS GROUND BAR Win Architectural tO rhea Use OR PRIOR APPROVED EQUAL YP A DISCCON CONTINUATION MC,M.C. MECHANICAL CONTRACTOR ITS TELECOMMUNICATIONS TERMINAL BOARD vAth ATtllit¢CtUre118.No other US¢, U) DISC DISCONNECT SWITCH MDB MAIN DISTRIBUTION BOARD TYP TYPICAL E.C.,EC ELECTRICAL CONTRACTOR dissemination,Of duel 11 may he K ICHEER: 9234BA LED MDR MAIN DISTRIBUTION PANEL W UNLESS NOTED OTHERWISE T WALL MOUNT ELV DIMMING LED WALL PACK LIGHT FIXTURE. MOUNT WALL PACKS AT (E) EXISTING TO REMAIN MFR MANUFACTURER w WALL-MOUNTED DEVICE made without pna wniKen consent of 1 TYPE (J1) OR PRIOR APPROVED EQUAL '3000K' DRIVER 120 <25 8'-O" UNLESS OTHERWISE NOTED ON THE PLANS, ELECT ELECTRICAL MILD MAIN LUGS ONLY WP WEATHERPROOF-IN-USE Archh¢cture118.All common law nights 3000LM COORDINATE FINAL MOUNTING HEIGHT WITH ARCHITECTS EP0 EMERGENCY POWER OFF (N) NEW WR WEATHER-RESISTANT ofcopynghtamhereloyspecifxxlly PRIOR TO INSTALLATION. PROVIDE WITH LED BULB(S). GFCI,OFGROEND FAULT CIRCUIT INTERRUPTER NEC NATIONAL ELECTRICAL CODE (X) EXISTING TO BE REMOVED reserved. CUD GROUND NIL NIGHT LIGHT COOPER: NAV-SA2-D-730-U-T3-BK LED POLE MOUNT 0-10V DIMMING EXTERIOR POLE MOUNTED SITE LED FIXTURE. PROVIDE REVISIONS: TYPE (S1) POLE: COOPER: ARP-M-6-18-A-BK-5 '3000K' DRIVER 120 129 WITH POLE AND TYPE 3 DISTRIBUTION.AT 20-0" ' osrvouMzn vnrza OR PRIOR APPROVED EQUAL 15883LM ® � C\1 A.F.G. CONSTRUCTION NOTES COOPER: ARB-B3-LED-DI-T3-AP-ARSA LED 0-10V DIMMING EXTERIOR POLE MOUNTED SITE LED FIXTURE. PROVIDE WITH POLE MOUNT 120 96 POLE AND TYPE 3 DISTRIBUTION AND SINGLE POLE MOUNT Oj MONUMENT SIGN.PROVIDE(2) 1"CONDUITS TO SIGN LOCATION.CORDINATE FINAL POWER TYPE (S3) POLE: COOPER: ARP-M-6-10-A-BK-5 '3000K' AT 15'-4" DRIVER CONNECTIONS AND MOUNTING DETAILS WITH SIGN PROVIDER AND ARCHITECT PRIOR TO OR PRIOR APPROVED EQUAL 850OLM ARM. FIXTURE HEIGHT AND ARM MOUNT TOTAL 40". TOP ROUGH IN.POWER AND CONTROL FROM SITE LIGHTING CIRCUIT. ' A.F.G. OF FIXTURE WITH 10' POLE, AND 2' BASE WILL BE 15'-4". 0PROVIDE(2) 1"CONDUITS TO BELL TOWER FOR FUTURE POWER OR DATA AT THIS 2 LOCATION.CAP AND MARK CONDUITS FOR FUTURE USE. T ' O REFER TO RECTORY AND PARISH CENTER DRAWINGS FOR BUILDING MOUNT LIGHTING 1 SPECIFICATIONS,POWER AND CONTROLS. i OPOWER SITE LIGHTING FROM CIRCUIT(D-3)WITHIN PARISH CENTER.CONTROL VIA THE ASTRONOMICAL TIME CLOCK LOCATED IN THE BASEMENT.REFER TO PARISH CENTER U) DRAWINGS FOR EXACT LOCATION. OPROVIDE POWER FOR SHED LIGHTING FROM THE NEAREST EXISTING RECEPTACLE CIRCUIT 11/.'.�■`/ WITH AVAILABLE CAPACITY. 5'SUBSETS& o O REMOVE EXISTING SITE LIGHTS FOR ADDITION. Q GENERAL NOTES I� O 1. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INCLUDING EQUIPMENT SUPPLIERS TO COORDINATE WITH EACH OTHER AND TO VERIFY THAT THERE ARE NO CONFLICTS IN 7 O - LOCATIONS OF DUCTS,CONDUITS,SPRINKLER HEADS,SPRINKLER PIPING, DIFFUSERS, ` ELECTRICAL BOXES AND OTHER ITEMS THROUGHOUT THIS PROJECT,BEFORE FINAL O PLACEMENT OF MATERIALS. 2. REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL INFORMATION: DETAILED EQUIPMENT REQUIREMENTS,INSTALLATION INSTRUCTIONS, PERFORMANCE REQUIREMENTS,CONTROL SEQUENCES AND ALL OTHER PROJECT DETAILS. 3. INSTALL ALL NEW WORK TO MEET CURRENT CODES AND INSTALLATION STANDARDS. (N)ISLMDWENTRY nH' mnISIANDDESACTAS 4. WIRING FOR SITE LIGHTS SHALL BE UNDERGROUND AND IN A MINIMUM OF 1"DIAMETER V SCHEDULE 40 PVC CONDUIT AND#10 CU.CONDUCTORS AS NOTED ON THE PLANS. W ALL WIRING SHALL BE INSTALLED TO MEET THE NATIONAL ELECTRIC CODE.PULL BOXES / F-7-1] SHALL BE REINFORCED CONCRETE AND SHALL BE LOCATED AS SHOWN ON THE PLANS. ---------------------- ------------------- -------�-� � 5. PROVIDE AND INSTALL NORMAL POWER,INSTALLED UNDERGROUND PER THE LATEST " e F EDITION OF THE NATION ELECTRIC CODE.CONDUIT SHALL BE INSTALLED WITH A 4 a o o E MINIMUM COVER REQUIREMENT OF 18 INCHES BELOW FINISHED GRADE. 8 6. COORDINATE FINAL LOCATIONS OF THE LIGHT POLES,AND JUNCTION BOXES WITH FINAL " ROAD AND SIDEWALKS. UP ADAPARKINGSIGI I(A INGaADARAAIP ;+ 7. PROVIDE LIGHT POLE BASES PER LIGHT POLE MANUFACTURERS REQUIREMENTS AND (Nt CONCSTAIRS R _V� - (EI MONUMENTSIGN, PARKING LOT LIGHT POLE BASE DETAIL.CONTRACTORTORUNCONDUITPOR .FUTURE UPGRADE,ME ELECTRICAL POLE WITH LUMINAIRE TO WITHSTAND 100 D2 ED F �- MPH WIND. OWNER: W V T��—� -IEIDELLrowER PV CONDUIT STUBBED UP (Et ELECTRICAL TRANSFORMER * (X) 3 �•(x) �p I ! �;--[ ,� ADJACENT TO HANDHOLE, NUMBER AND SIZE AS POLE PARENTERI STUDENT CR ADDITION(PC) _ ---- Q REQUIRED. — _ LEVELING NUTS 0 3/4"DIA.X 40"LONG GROUT AS REQ'D. ANCHOR BOLTS(4). 3/4"CHAMFER COORDINATE WITH I 15'tl MANUFACTURER'S 04 CONCRETE BASE GROUT REQUIREMENTS. A:A FOR SMOOTH FINISH 6"CURB FINISHED GRADE #4 RED-8 EA. i _I NC.SIDEWALK,CONC STEPS W/#3 TIES- 12:O.C. -- ¢ OUENE OF EXISTING BUILDING Ji � - -' PROJECT LOCATION: A-24 ATTACHED TO SULATED INTERNAL LUGPER GUS NDUIT I a scHE3.40 PVC 8=so" WELDED TO INTERIOR OF POLE S11TH AVE.BOZEM{w MT o. MIN.30"BURY B. C=24"SQUARE SIZE GOD CONDUIT PER NFPA 70. O IN CDNC.BIDEWALKI RAMP (NIIAEE5LANDIUTING a Mo cJ .SEE LPNDSf,APEPMN,IYP EPGOE COPPER EQUIP GROUND DESIGN TEAM: ® I® "C" CONDUIT CIRCUIT CTO Lu"TO POLEND CONDUCTOR ATTACH TO INTERNAL LUG WELDED TO INTERIOR OF POLE. ® r__ ENGINEERING EXISTING PARISH CENTER(PC) °°"°ANDCC�°�UT Ro **SQUARE POLE BASE w''c I POWER SOURCE OF TO MATCH EXISTING** NEXT POLE. ® (E)CROSS ga� o+ 19MM X 3050MM (3/4"x10')GROUND ROD PARKING LOT LIGHT POLE BASE DETAIL Q NO SCALE /� 53 C CDS (N CONC.PAPO L ENGINEERING (N TREESI LANDSCAPING, YA poi[ieii•1° SEE LANDSCAPE PLAN.ttP O •xw.e [eniNs.eoM it POLE WITH LUMINAIRE TO WITHSTAND 100 EXISTING SANCTUARY MPH WIND. Ji Ji J1 PV CONDUIT STUBBED UP ADJACENT TO D SIZE AS NUMBER AND SIZE AS POLE REQUIRED. RELOCATE(E)SHED G1 LEVELING NUTS D 3/4"DIA.X 40"LONG GROUT AS REO'D. ANCHOR BOLTS(4). Gi ° J1 3/4„CHAMFER COORDINATE WITH 18 O3 MANUFACTURER'S architecture one eighteen CONCRETE BASE GROUT REQUIREMENTS. 5 115 east oak street bowman cot 59715 NEW RECTORY(R) FOR SMOOTH FINISH -- CURB SHEET NUMBER: v0 04 REBAR-8 EA. FINISHED GRADE LU W/#3 TIES- 12:O.C. - - (NCONCRETESIDswALK _ INSULATED COPPER GND CONDUIT ® B" A-24 ATTACHED TO INTERNAL LUG ES 1 SCHED.40 PVC B=48" WELDED TO INTERIOR L POLE. cO MIN.30"BURY C=24"SQUARE SIZE GND CONDUIT PER NFPA 70. 5'SIDESEIBACK ° Boa o '° —.a SHEET TITLE', COPPER EQUIP GROUND CONDUCTOR ATTACH TO INTERNAL •C" CIRCUIT CONDUCTORS AND LUG WELDED TO INTERIOR OF POLE. CONDUIT TO NEXT POLE. SITE PLAN- CONDUIT CONDUCTORS **SQUARE POLE BASE POWER AND CONDUIT TO TO MATCH EXISTING*" POWER SOURCE OF LF NEXT POLE. 19MM X 3050MM (3/4"00')GROUND ROD ExTGOFFICEBLDG WALKWAY LIGHT POLE BASE DETAIL NO SCALE PHASE: "get Status PERMITIBID SET 21-023C OWIWN BY: CHECKED BY: LUTTW TTW w SITE PLAN-POWER iL DECEMBER 20,2024 a ® SCALE:1"=20'-0"