Loading...
HomeMy WebLinkAbout071_A101.c_FirstFloorPlanA201 4 1 1 2 2 3 3 4 4 5 5 6 6 8 8 A A C C H H REF. TO PEMB FOR MTL BUILDING DIMS J J 1 A301 __________ 1 A301 __________ 2 A301 __________2 A301 __________ REF. TO PEMB FOR MTL BUILDING DIMS 14074 SF DRIVE THRU 101 210 SF STORAGE 102 7 B B F F G G 4' - 6"8' - 0"7' - 6"22' - 6"2' - 6" 22' - 6"2' - 6"2' - 6"3' - 6"21' - 6"2' - 6"EW1 BY PEMB EW1 BY PEMB EW1 BY PEMB EW1 BY PEMB EW1 BY PEMB EW1 BY PEMB EW1 BY PEMB 101B101F102B 102A 101C101D101G101H101A 101EOVHD, BY OWNEROVHD, BY OWNEROVHD, BY OWNEROVHD, BY OWNERDOOR BY PEMB DOOR BY PEMB DOOR BY PEMB DOOR BY PEMB 3 A301 __________ 3 A301 __________REF. TO PEMB FOR MTL BUILDING DIMSREF. TO PEMB FOR MTL BUILDING DIMS12' - 6"7' - 6" STL PIPE BOLLARD STL PIPE BOLLARD STL PIPE BOLLARD STL PIPE BOLLARD DOWNSPOUT BY PEMB, TYP. DOWNSPOUT BY PEMB, TYP. A 201.c 4 W H E A T D RIV E R AIL R O A D KEYPLAN PLAN NORTH GENERAL SHEET NOTES A. PROVIDE FIRE EXTINGUISHERS AND FIRE EXTINGUISHER CABINETS AS SHOWN / SPECIFIED. COORDINATE FINAL LOCATIONS WITH FIRE MARSHALL. B. SEE A003 FOR ALL PARTITION AND WALL ASSEMBLY TYPES. ALL FRAMING AND FINISHES OF INTERIOR WALLS TO EXTEND TO THE UNDERSIDE OF STRUCTURE ABOVE UNLESS NOTED OTHERWISE. C. SEE A001 FOR DETAILED INFORMATION ON DIMENSIONING D. DASHED BOXES AND CIRCLES SHOW CLEAR FLOOR AREA. DASHED AREAS ARE FOR REFERENCE AND NOT ALL ARE SHOWN E. CONTRACTOR TO COORDINATE ADDITIONAL FRAMING WITH EXTERIOR CLADDING ATTACHMENTS AND FASTENERS F. FOR DOOR OPENING DIMENSIONS SEE DOOR SCHEDULE IN A600 SHEETS G. SEE A600 SHEETS FOR FINISH SCHEDULE H. ABBREVIATIONS: REFERENCED FROM THE CONSTRUCTION SPECIFICATIONS INSTITUTE'S UNIFORM DRAWING SYSTEM TERMS AND ABBREVIATIONS MODULE. REFER TO SHEET A001 - ARCHITECTUAL GENERAL NOTES. I. CONTRACTOR TO FEILD VERIFY ALL FOUNDATION AND FOOTING HEIGHTS. J. CONTRACTOR TO COORDINATE ALL SITE DRAINAGE. K. ALL STRUCTURAL ELEMENTS ARE TO BE REVIEWED BY A LICENSED STRUCTURAL ENGINEER. L. EXTERIOR BUILIDNG DIMENSIONS ARE TO GRID CENTERLINE, EXTERIOR F.O. SHEATHING/OUTSIDE FACE OF FOUNDATION. M. DIMENSIONS ARE TO GRID CENTERLINE, FACE OF CONCRETE WALL OR FACE OF STUD AS APPLICABLE, UNLESS NOTED OTHERWISE N. ALL INTERIOR DOORS ARE 4 1/2" AWAY FROM ADJACENT PERPINDICULAR STUD , UNLESS SPECIFICALLY DIMENSIONED. O. CONTRACTOR TO COORDINATE ALL HVAC. COORDINATE WITH ARCHITECT FOR ANY FLOOR PLAN CHANGES. P. CONTRACTOR TO COORDINATE ALL ELECTRICAL REQUIREMENTS. Q. CONTRACTOR TO COORDINATE ALL STRUCTURAL SHEAR REQUIREMENTS W/ A LICENSED STRUCTURAL ENGINEER. R. REFER TO ARCHITECTURAL SHEET SERIES 200 EXTERIOR ELEVATIONS FOR THE IDENTIFICATION OF VARIOUS EXTERIOR WALL MATERIAL TYPES, LOCATIONS, AND EXTENTS. S. COORDINATE T.O. FOUNDATION WALL AND FINISH FLOORING WITH NEW GRADE. Date Project Number Sheet Name ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF 45 ARCHITECTURE REVISIONS ALL DRAWN AND WRITTEN INFORMATION APPEARING ON THIS DRAWING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF 45 ARCHITECTURE.MARK DESCRIPTION DATE 7/31/2024 4:09:01 PMA 101.c FIRST FLOOR PLANSIMKINS DRIVE THRU BUILDING04.22.2024 23009SIMKINS NORTH PARK TRACT 2-BWHEAT DRIVEBOZEMAN, MT 59715SITE PLAN SUBMITTAL NORTH 1/8" = 1'-0"A 101.c 1 DRIVE-THRU BUILDING (WILL CALL) - LEVEL 1 - Dependent 1