HomeMy WebLinkAbout067_A103.b_RoofPlanA202.b
2
A201.b
2
A202.b
1
A201.b
1 1
A301
2
A301
A
A
E
E
G
G
I
I
K
K
M
M
O
O
Q
Q
S
S
U
U
22
33
44
C
C
D
D
F
F
H
H
J
J
L
L
N
N
P
P
R
R
T
T
B
B
V
V4" / 12"4" / 12"2" / 12"2
A302
252' - 0"
252' - 0"27' - 6"2' - 6"60' - 0"2' - 6"27' - 6"2' - 0"2' - 0"
1' - 0"
2' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"2' - 0"
1' - 0"
2' - 0"
2' - 0"
1' - 0"
2' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"2' - 0"
1' - 0"
2' - 0"2' - 0"27' - 6"2' - 6"60' - 0"2' - 6"27' - 6"2' - 0"1
A302
2
A532
1
A303
A407
1
11
W
W
X
X
WALL BELOW2" / 12"2" / 12"120' - 0"120' - 0"WALL BELOW
WALL BELOW
3
A302
SNOW GUARD SYS, PER MFG.
SNOW GUARD SYS, PER MFG.
SNOW GUARD SYS, PER MFG.
SNOW GUARD SYS, PER MFG.
SHT MTL GUTTER
SHT MTL GUTTER
SHT MTL GUTTER
SHT MTL GUTTER
RIDGE
8
A500
TYP.
REF 2/A201.b
4
A500
REF 2/A201.b
16
A501
REF 2/A201.b
14
A501
TYP.
14
A501
TYP.
Z
Y
5
ROOFTOP MECHANICAL UNITS, REF MEP
W
H
E
A
T D
RIV
E
R
AIL
R
O
A
D
KEYPLAN
PLAN NORTH
GENERAL SHEET NOTES
A. REFERENCE MECHANICAL, PLUMBING, AND ELECTRICAL
DRAWINGS FOR ADDITIONAL ROOF PENETRATIONS NOT
SHOWN HERE.
B. REFERENCE SHEET A530 FOR TYPICAL ROOF DETAILS NOT
FLAGGED HERE.
C. MINIMUM SLOPE OF CRICKETS TO BE 1/4" PER FT UNLESS
NOTED OTHERWISE. CONTRACTOR TO PROVIDE ALL
CRICKETS REQ'D TO PROVIDE POSITIVE DRAINAGE TO
DRAINS.
D. COORDINATE ROOF PENETRATION CURB AND FLASHING
REQUIREMENTS WITH AFFECTED TRADES.
E. COORDINATE SELECTED MANUFACTURER'S REQUIRED CLEAR
OPENING WIDTH FOR ALL ROOF TOP EQUIPMENT WITH
MECHANICAL COORDINATION SHOP DRAWINGS.
F. PROVIDE ICE AND WATER SHIELD AT ALL ROOF OVERHANGS
AND VALLEYS TO 24" MIN. BEYOND BUILDING PERIMETER.
G. MAINTAIN ALL ROOF DRAINS CLEAN AND FREE-FLOWING
DURING AND UPON COMPLETION OF CONSTRUCTION.
H. PAINT ALL ROOF TOP EQUIPMENT, ACCESSORIES, FLASHING,
ETC. THAT IS NOT PAINTED OR FACTORY FINISHED.
LEGEND
MEMBRANE ROOF OVER TAPERED
INSULATION (R2)
METAL ROOF OVER SIP SYSTEM (R1)
Date
Project Number
Sheet Name
ALL DRAWN AND WRITTEN INFORMATION
APPEARING SHALL NOT BE DUPLICATED,
DISCLOSED OR OTHERWISE USED
WITHOUT THE WRITTEN CONSENT OF
45 ARCHITECTURE
REVISIONS
ALL DRAWN AND WRITTEN INFORMATION APPEARING ON THIS DRAWING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF 45 ARCHITECTURE.MARK DESCRIPTION DATE
KEYPLAN
7/31/2024 4:47:43 PMA103.b
ROOF PLANSIMKINS LUMBER RETAIL BUILDING07.31.2024
23006BOZEMAN, MTCONSTRUCTION DOCUMENTS
3/32" = 1'-0"A103.b
1 ROOF PLAN
PLAN NORTH