Loading...
HomeMy WebLinkAbout061_A101.a_FirstFloorPlanCRDC J 4 4DOS3 FN-1 T OS3 3 3 334DFFFF FFFF EH-3 T EH-4 T 20' OH DOOR 20' OH DOOR 24' OH DOORA201 1 A201 2 A201 4 A201 3 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 A A B B C C REF. PEMB FOR MTL BUILDING DIMS REF. PEMB FOR MTL BUILDING DIMS2 A301 __________ 3 A301 __________REF. PEMB FOR MTL BUILDING DIMSREF. PEMB FOR MTL BUILDING DIMS 1 A301 __________ D D 9 9 21' - 0"4' - 0"30' - 0"3' - 0"13' - 2"16' - 0"14' - 9" 3' - 0"27' - 8 1/2"30' - 8 1/2"2' - 5"28' - 3 1/2"30' - 8 1/2"30' - 8 1/2"3' - 0"27' - 8 1/2" 4 A301 __________ TRUSS MANUFACTURING 101 101J 101D 104A104C101H101G101B101A103A101M101L101E101K CYBER SAW 104 MECH. 102 R.R. 103 BREAK 105 R.R. 106 R.R. 107 EW1 BY PEMBEW1 BY PEMB EW1 BY PEMB EW1 BY PEMB EW1 BY PEMB EW1 BY PEMB EW1 BY PEMB EW1 BY PEMB 5' - 9" F.O. 5' - 0"14' - 3"101C101F 19' - 10" 102A DOOR BY PEMB OVHD, BY OWNER 7' - 0"5' - 0"101N OVHD, BY OWNER OVHD, BY OWNER OVHD, BY OWNEROVHD, BY OWNEROVHD, BY OWNEROVHD, BY OWNER OVHD, BY OWNER OVHD, BY OWNER DOOR BY PEMB DOOR BY PEMB DOOR BY PEMB DOOR BY PEMB DOOR BY PEMB104BA403 14 A.1 A.1 A.25 A.4 A.7 A.9 B.2 B.35 B.4 B.5 B.7 B.9 A.2 A.3 A.5 A.8 B.1 B.3 B.6 B.8 2.9 5.1 IW1-4 IW1-4 DOWNSPOUT BY PEMB, TYP.19' - 0"3' - 0"STL PIPE BOLLARD STL PIPE BOLLARD STL PIPE BOLLARDSTL PIPE BOLLARDDOWNSPOUT BY PEMB, TYP. STL PIPE BOLLARD STL PIPE BOLLARD STL PIPE BOLLARD A 201.a 1 A 201.a 2 A 201.a 4 A 201.a 3 WH E A T D RIV E R AIL R O A D KEYPLAN PLAN NORTH GENERAL SHEET NOTES A. PROVIDE FIRE EXTINGUISHERS AND FIRE EXTINGUISHER CABINETS AS SHOWN / SPECIFIED. COORDINATE FINAL LOCATIONS WITH FIRE MARSHALL. B. SEE A003 FOR ALL PARTITION AND WALL ASSEMBLY TYPES. ALL FRAMING AND FINISHES OF INTERIOR WALLS TO EXTEND TO THE UNDERSIDE OF STRUCTURE ABOVE UNLESS NOTED OTHERWISE. C. SEE A001 FOR DETAILED INFORMATION ON DIMENSIONING D. DASHED BOXES AND CIRCLES SHOW CLEAR FLOOR AREA. DASHED AREAS ARE FOR REFERENCE AND NOT ALL ARE SHOWN E. CONTRACTOR TO COORDINATE ADDITIONAL FRAMING WITH EXTERIOR CLADDING ATTACHMENTS AND FASTENERS F. FOR DOOR OPENING DIMENSIONS SEE DOOR SCHEDULE IN A600 SHEETS G. SEE A600 SHEETS FOR FINISH SCHEDULE H. ABBREVIATIONS: REFERENCED FROM THE CONSTRUCTION SPECIFICATIONS INSTITUTE'S UNIFORM DRAWING SYSTEM TERMS AND ABBREVIATIONS MODULE. REFER TO SHEET A001 - ARCHITECTUAL GENERAL NOTES. I. CONTRACTOR TO FEILD VERIFY ALL FOUNDATION AND FOOTING HEIGHTS. J. CONTRACTOR TO COORDINATE ALL SITE DRAINAGE. K. ALL STRUCTURAL ELEMENTS ARE TO BE REVIEWED BY A LICENSED STRUCTURAL ENGINEER. L. EXTERIOR BUILIDNG DIMENSIONS ARE TO GRID CENTERLINE, EXTERIOR F.O. SHEATHING/OUTSIDE FACE OF FOUNDATION. M. DIMENSIONS ARE TO GRID CENTERLINE, FACE OF CONCRETE WALL OR FACE OF STUD AS APPLICABLE, UNLESS NOTED OTHERWISE N. ALL GRIDS ARE BY PEMB MANUFACTURER, VERIFY GRIDS AND DIMENSIONS WITH PEMB DRAWINGS O. ALL INTERIOR DOORS ARE 4 1/2" AWAY FROM ADJACENT PERPINDICULAR STUD , UNLESS SPECIFICALLY DIMENSIONED. P. CONTRACTOR TO COORDINATE ALL HVAC. COORDINATE WITH ARCHITECT FOR ANY FLOOR PLAN CHANGES. Q. CONTRACTOR TO COORDINATE ALL ELECTRICAL REQUIREMENTS. R. CONTRACTOR TO COORDINATE ALL STRUCTURAL SHEAR REQUIREMENTS W/ A LICENSED STRUCTURAL ENGINEER. S. REFER TO ARCHITECTURAL SHEET SERIES 200 EXTERIOR ELEVATIONS FOR THE IDENTIFICATION OF VARIOUS EXTERIOR WALL MATERIAL TYPES, LOCATIONS, AND EXTENTS. T. COORDINATE T.O. FOUNDATION WALL AND FINISH FLOORING WITH NEW GRADE. Date Project Number Sheet Name ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF 45 ARCHITECTURE REVISIONS ALL DRAWN AND WRITTEN INFORMATION APPEARING ON THIS DRAWING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF 45 ARCHITECTURE.MARK DESCRIPTION DATE 7/31/2024 4:13:37 PMA 101.a FIRST FLOOR PLANSIMKINS LUMBER TRUSS SHOP07.31.2024 23009SIMKINS NORTH PARK TRACT 4-BWHEAT DRIVEBOZEMAN, MT 59715CONSTRUCTION DOCUMENTS 1/16" = 1'-0"A 101.a 1 TRUSS BUILDING - LEVEL 1 - SP PLAN NORTH