HomeMy WebLinkAbout8.0 C2.2 Stormwater DetailsSTORMTECH ENDCAP,TYP. OF 2WRAP WITH GEOTEX601 NON-WOVEN FABRICOR EQUIVALENTCONNECTCHAMBERS,TYP.CHAMBER 1CHAMBER 318" ADS N-12 CORRUGATEDPIPE, BOTTOM OF PIPEFLUSH WITH BOTTOM OFCHAMBERINSTALL 2 ROWS OF 3 CHAMBERS (6 CHAMBERS TOTAL)INSTALL 1ST ROW AS ISOLATOR ROW36" I.D. MANHOLE18" ADS N-12 CORRUGATED PIPE,BOTTOM OF PIPE FLUSH w/BOTTOM OF CHAMBERGEOTEX 601 NON-WOVEN FABRICALL AROUND ANGULAR STONEISOLATORROWGEOTEX 601 NON-WOVEN FABRIC ALLAROUND ISOLATOR ROW BETWEENCHAMBER & ANGULAR STONE2 ROWS OF (3) SC-740 CHAMBERS(6 CHAMBERS TOTAL)DTL 2/C2.236" I.D CONCRETE STANDARDSTORM DRAIN INLET PER COBSTD DTL 02720-1, USE NEENAHR-3067-C INLET FRAME & GRATE6" PRECAST BASEDTL 3/C2.212"6"INV. OUTEL. 4811.75'MATERIAL LOCATIONDESCRIPTIONCFILL MATERIAL FOR 6" TO 18"ELEVATION ABOVE CHAMBERS(24" FOR UNPAVED INSTALLATIONS)EMBEDMENT STONE SURROUNDINGAND TO A 6" ELEVATION ABOVECHAMBERSBGRANULAR WELL-GRADEDSOIL/AGGREGATE MIXTURES,<35% FINES.CLEAN ANGULAR STONE WITH THEMAJORITY OF PARTICLES BETWEEN¾ - 2 INCHFOUNDATION STONE BELOWCHAMBERSACLEAN ANGULAR STONE WITH THEMAJORITY OF PARTICLES BETWEEN¾ - 2 INCHAASHTO M43DESIGNATION3, 357, 4, 467,5, 56, 57, 6,67, 68, 7, 78,8, 89, 9, 103, 357, 4, 467, 5,56, 573, 357, 4, 467,5, 56, 57N/AN/AA-1A-2A-3AASHTO M145DESIGNATIONCOMPACTION/DENSITYREQUIREMENTCOMPACT IN 6" LIFTS TO A MINIMUM 95%STANDARD PROCTOR DENSITY. ROLLER GROSSVEHICLE WEIGHT NOT TO EXCEED 12,000 LBS.DYNAMIC FORCE NOT TO EXCEED 20,000 LBS.NO COMPACTION REQUIREDPLATE COMPACT OR ROLL TO ACHIEVE A95% STANDARD PROCTOR DENSITYACCEPTABLE FILL MATERIALSSTORMTECH SC-740 CHAMBER SYSTEMSNOTE: THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN CRUSHED ANGULAR.MIN.GRANULAR WELL GRADED SOIL/AGGREGATE MIXTURES,<35% FINES. COMPACT IN 6 IN LIFTS TO 95% PROCTOR DENSITY.SEE THE TABLE OF ACCEPTABLE FILL MATERIALS .6"¾ - 2 INCH CLEAN,CRUSHED, ANGULAR STONESC-740 END CAP6"30"12" MIN. TYP.51"12" MIN.3" ASPHALTGEOTEX 601 NON-WOVEN FABRICSC-740 CHAMBER6"3" OF 1" MINUSCRUSHED BASESTUBS AT TOP OF ENDCAP FOR PARTS NUMBERSENDING WITH "T"STUBS AT BOTTOM OF ENDCAP FOR PARTS NUMBERSENDING WITH "B" FOR THE SC740EPE24B THE 24"STUB LIES BELOW THE BOTTOM OF THEEND CAP APPROXIMATELY 1.75".BACKFILL MATERIAL SHOULD BEREMOVED FROM BELOW THE N-12 STUBSO THAT THE FITTING SETS LEVEL.NOTE: ALL DIMENSIONS ARE NOMINAL*90.7" ACTUAL LENGTH85.4" INSTALLEDNOMINAL CHAMBER SPECIFICATIONSSIZE (W x H x INSTALLED LENGTH) -CHAMBER STORAGE -MINIMUM INSTALLED STORAGE -WEIGHT -30.0"51.0" x 30.0" x 85.4"45.9 CUBIC FEET74.9 CUBIC FEET74 LBS.51"*PART #CHAMBERPIPE SIZEABCSC740EPE06TSC-7406 in (150 mm)10.90 in (277 mm)18.50 in (470 mm)N/ASC740EPE06B6 in (150 mm)10.90 in (277 mm)N/A0.50 in (13 mm)SC740EPE12T12 in (300 mm)14.70 in (373 mm)12.50 in (318 mm)N/ASC740EPE12B12 in (300 mm)14.70 in (373 mm)N/A1.20 in (30 mm)SC740EPE15T15 in (375 mm)18.40 in (467 mm)9.00 in (229 mm)N/ASC740EPE15B15 in (375 mm)18.40 in (467 mm)N/A1.30 in (33 mm)SC740EPE18T18 in (450 mm)19.70 in (500 mm)5.00 in (127 mm)N/ASC740EPE18B18 in (450 mm)19.70 in (500 mm)N/A1.60 in (41 mm)SC740EPE24B24 in (600 mm)18.50 in (470 mm)N/A0.10 in (3 mm)ABACSC-740SC-740SC-740SC-740SC-740SC-740SC-740SC-740SC-740SC-740SC-740SC-740SC740EPE08TSC740EPE08BSC740EPE10TSC740EPE10BALL STUBS, EXCEPT FOR THE SC740EPE24BARE PLACED AT BOTTOM OF END CAP SUCHTHAT THE OUTSIDE DIAMETER OF THE STUB ISFLUSH WITH THE BOTTOM OF THE END CAP.FOR ADDITIONAL INFORMATION CONTACTSTORMTECH AT 1-888-892-2694.8 in (200 mm)8 in (200 mm)10 in (250 mm)10 in (250 mm)N/A0.60 in (15 mm)16.50 in (419 mm)N/A14.50 in (368 mm)N/AN/A0.70 in (18 mm)12.20 in (310 mm)12.20 in (310 mm)13.40 in (340 mm)13.40 in (340 mm)11'USE THIS72"(6'-0)12" MIN. SUMP36" I.D.PRECASTSTORM DRAINRIM ELEV. 4816.25'ELEV. 4810.25'C2.2CIVIL and STRUCTURAL ENGINEERING PROJECT MANAGEMENTBEI BRIDGER ENGINEERS, INC. ARCHITECT CONSTRUCTION NOTES:1.STORMTECH CHAMBERS AND DRAIN BASIN TO BEINSTALLED PER MANUFACTURER'S RECOMMENDATIONS.2.CHAMBER LAYOUT TO CONSIST OF ONE (2) ROWS WITHTHREE (3) CHAMBERS EACH.3.1ST CHAMBER ROW IS TO BE INSTALLED AS AN ISOLATORROW FOR FUTURE FLUSHING & MAINTENANCE. SEEMANUFACTURER'S INSTRUCTIONS FOR INSTALLATION OFTHE ISOLATOR ROW.