HomeMy WebLinkAbout16--A4.1 - CONSTRUCTION ROOF PLANDW TR
REF
REF
REF W/DW/DREF
A
A5.1
A
A5.1
12" / 12"12" / 12"12" / 12"12" / 12"12" / 12"12" / 12"
24" / 12"24" / 12"24" / 12"24" / 12"24" / 12"5" / 12"5" / 12"5" / 12"
(N) RIDGE
(E) RIDGE
(E) RIDGE(E) RIDGE(E) RIDGE(E) RIDGE(E) RIDGE (N) VALLEY(E) VALLEY(E) VALLEY(E) VALLEY(N) VALLEY(N) VALLEY(E) VALLEY(E) VALLEY(E) HIP(E) HIP(E) HIP(E) HIP(E) HIP(E) HIP(E) HIP(E) HIPH
A5.4
H
A5.4
I
A5.4
I
A5.4
C
A5.2
C
A5.2
B
A5.1
B
A5.1(E) RIDGE(N) VALLEY(N) VALLEY(N) VALLEY(N) RIDGE
(N) PITCH CHANGE(N ) V A L L E Y(E) VALLEY12" / 12"
12" / 12"
12" / 12"12" / 12"12" / 12"
12" / 12"12" / 12"12" / 12"12" / 12"12" / 12"12" / 12"3" / 12"
12" / 12"
12" / 12"12" / 12"12" / 12"+119' -8" T.O.PLATE
+120' -4" T.O.PLATE
+125' -0" T.O.PLATE
T.O. BENCH +101' - 6"TYP.1' - 8"1' - 6"
T.O. CHIMNEY +135' - 8"1' - 8" TYP.T.O PARAPET +122' - 8"
T.O PARAPET +122' - 8"
1/4" / 12"1/4" / 12"
J
A5.4
J
A5.4
1/4" / 12"1/4" / 12"1/4" / 12"E
A5.2
E
A5.2
F
A5.3
F
A5.3
K
A5.4
K
A5.4
D
A5.2
D
A5.2
R3
R2
R3
R2
R3
R3
R1
R1
G
A5.3
G
A5.3
FIRE SEPARATION
1
1 2
3
4
5
5
6
6
BB
CC
DD
EE
FF
GG
HH
II
JJ
7
7
+125' -6" T.O.PLATE(N) RIDGER3
R3
12" / 12"12" / 12"12" / 12"8
8
3
A9.5
3
A9.5
A9.5
7 TYP.
A9.5
7 TYP.
A9.5
1
A9.5
1
(N) CHIMNEY
CRICKET
A9.5
7 TYP.(N) RIDGEA9.5
10
A9.5
10
A9.5
1
A9.5
3
A9.5
3
AA
R1
R2
A9.5
6
A9.5
2 SIM.
A9.5
2 SIM.
A9.5
7 TYP.
A9.5
6
A9.5
6
A5.7
4
R5
R5
1/8" / 12"
1/8" / 12"
1/4" / 12"1/4" / 12"
22.422.4
1/4" / 12"
22.4
22.4
22.4
R1
R1
22.4
R4
1/4" / 12"
+100' -0" T.O.PLATE
T.O PARAPET +103' - 4"
+100' -0" T.O.PLATE
MATCH EXISTING PLATE
7.2
4.1
5.2
7.2
5.2
6.4
A9.5
11 TYP.
A9.5
10 SIM.
A9.5
14
A9.5
10
A9.5
5
A9.5
13
A9.5
13~ 5' - 0"7.1 ~ 5' - 3"7.1
7.1
7.1
7.1
A9.5
14
A9.5
15
A9.5
15
A9.5
14
PER IRC SECTION R318 - ATTIC RAFTERS ARE FULLY
INSULATED TO ELIMINATE THE NEED FOR ATTIC VENTING.
A. SEE SHEET A9.4/9.5 FOR TYPICAL EAVE, RAKE
AND PARAPET CONDITIONS.
B. FLASH ALL VALLEYS, HIPS AND CHANGE OF
PLAINS IN THE ROOF WITH ZINC OR PLATED
METAL EXTEND 12" MINIMUM UNDER ROOFING.
C. ALL ROOF PENETRATIONS SHALL BE FLASHED
AND SET IN MASTIC TO INSURE WATERPROOF
SEAL AND PAINTED TO MATCH ROOFING
MATERIAL.
D. VERIFY ANY ELECTRICAL ITEMS AND LOCATIONS
REQUESTED BY THE OWNER PRIOR TO
INSTALLING ROOF MEMBRANES.
E. TYPICAL ROOF PITCH VARIES - SEE ROOF PLAN.
F. ALL EAVES TO BE COVERED WITH AN ICE
BARRIER PER R905.1.2 THAT EXTENDS 24" MIN.
FROM EXTERIOR WALL LINE OF THE BUILDING.
+xx'-x" T.O. PLATE
+xxxx.xx
HEIGHT ABOVE
FINISH FLOOR OF
MAIN LEVEL
FIRE SEPARATION SHEATHING
APPLIED 48" MIN FROM CENTER
LINE OF PARTY WALL
BUILDING PER R302.2.3
SYMBOLS
GENERAL ROOF NOTESROOF ASSEMBLIES
XPS2 & XPS3 R-30CI,
(2) 3" STAGGERED LAYERS
ADHERED PER MFR
RECOMMENDATIONS
RAM1 HOT FLUID-APPLIED,
RUBBERIZED-ASPHALT
ROOFING MEMBRANE,
6125-FR BY HYDROTECH
OR APPROVED EQ.
R VALUE = R-13 + R-30CI
2-1/2"BALLAST1
SHEATHING PER STRUCT
2" FOAM2 R-13,
VAPOR RETARDER
FJ, REF STRUCT
5/8" GB1
SUB 1 GLASS-MAT GYPSUM
ROOF SUBSTRATE BOARD
ELD
STONE FILTER FABRIC
FLUID-APPLIED PMR
NEW CONSTRUCTIONR1
METAL SHINGLES
NEW CONSTRUCTIONR2
METAL SHINGLES
EXISTING CONSTRUCTIONR3
R VALUE= R-60
SHT1
PER STRUCT
SSP1
UNDER1
(E) TRUSS
TOP CHORD
9 1/4"FOAM2 R-60
(E) ROOF
SHEATHING
R VALUE= R-60
COAT1, NOT REQ.
WHERE GB1
OCCURS, REF RCPs
FOR LOCATIONS
SSP1
UNDER1
I-JOIST9 1/4"FOAM2 R-60
WOOD FRAMING, FLUID-APPLIED
PMR, WOOD PATIO DECKING
NEW CONSTRUCTIONR4
R-VALUE = R-13 + R-30CI
ADJUSTABLE PEDESTALS
WOOD PATIO DECKING, CPL1
CEILING, REF RCPS & SCHED
ELD
XPS2 & XPS3 R-30CI,
STAGGERED EDGES
RAM1
2" FOAM2 R-13
FJ PER STRUCT
SHT1 PER STRUCT3"3"SAME AS R4, EXCEPT 2" INSUL TO
SUPPORT CPL1 & NO FOAM2R5
5/8"GB1
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
G
H
1
PROJECT NO:
DATE:
20003
February 20, 2025
All reports, drawings, specifications, computer
files, field data, notes, other documents and
instruments prepared by the Architect as
instruments of service shall remain the property
of the Architect, LocalElementArchitects, LLC.
The Architect shall retain all common law,
statutory and other reserved rights, including
copyright thereto. The use of this drawing shall
be restricted to the original site for which it was
prepared and publication thereof is expressly
limited to such use. Reuse, reproduction or
publication by any method is prohibited without
written consent from LocalElementArchitects,
LLC.
N C O A
N O T F O R C O N S T R U C T IO N
2/20/2025 4:36:23 PM C:\Users\chris\OneDrive\Documents\20003--204_ S 3rd_Central_chrisTMMND.rvtSQUIRE C. KENYON LOFTS204 S. 3RD AVE.BOZEMAN MT, 59715A4.1
CONSTRUCTION
ROOF PLAN
NORTHSCALE: 3/16" = 1'-0"1 ROOF PLAN
KEYNOTES
4.1 MASONRY WALL CAP
5.2 RAIL1, DECORATIVE METAL RAILINGS W/ WOOD
RAILS, TYP.
6.4 TIMBER TRELLIS W/ ST1, TRANSPARENT STAIN
FINISH, REF STRUCT
7.1 OVERFLOW ROOF SCUPPER
7.2 RDFS1, ROOF SPECIALTIES
22.4 INTERNAL ROOF DRAIN, PLUMBING TBD BY
DESIGN/BUILD PLUMBER
REVISIONS
NO. DATE DESCRIPTION