Loading...
HomeMy WebLinkAbout16--A4.1 - CONSTRUCTION ROOF PLANDW TR REF REF REF W/DW/DREF A A5.1 A A5.1 12" / 12"12" / 12"12" / 12"12" / 12"12" / 12"12" / 12" 24" / 12"24" / 12"24" / 12"24" / 12"24" / 12"5" / 12"5" / 12"5" / 12" (N) RIDGE (E) RIDGE (E) RIDGE(E) RIDGE(E) RIDGE(E) RIDGE(E) RIDGE (N) VALLEY(E) VALLEY(E) VALLEY(E) VALLEY(N) VALLEY(N) VALLEY(E) VALLEY(E) VALLEY(E) HIP(E) HIP(E) HIP(E) HIP(E) HIP(E) HIP(E) HIP(E) HIPH A5.4 H A5.4 I A5.4 I A5.4 C A5.2 C A5.2 B A5.1 B A5.1(E) RIDGE(N) VALLEY(N) VALLEY(N) VALLEY(N) RIDGE (N) PITCH CHANGE(N ) V A L L E Y(E) VALLEY12" / 12" 12" / 12" 12" / 12"12" / 12"12" / 12" 12" / 12"12" / 12"12" / 12"12" / 12"12" / 12"12" / 12"3" / 12" 12" / 12" 12" / 12"12" / 12"12" / 12"+119' -8" T.O.PLATE +120' -4" T.O.PLATE +125' -0" T.O.PLATE T.O. BENCH +101' - 6"TYP.1' - 8"1' - 6" T.O. CHIMNEY +135' - 8"1' - 8" TYP.T.O PARAPET +122' - 8" T.O PARAPET +122' - 8" 1/4" / 12"1/4" / 12" J A5.4 J A5.4 1/4" / 12"1/4" / 12"1/4" / 12"E A5.2 E A5.2 F A5.3 F A5.3 K A5.4 K A5.4 D A5.2 D A5.2 R3 R2 R3 R2 R3 R3 R1 R1 G A5.3 G A5.3 FIRE SEPARATION 1 1 2 3 4 5 5 6 6 BB CC DD EE FF GG HH II JJ 7 7 +125' -6" T.O.PLATE(N) RIDGER3 R3 12" / 12"12" / 12"12" / 12"8 8 3 A9.5 3 A9.5 A9.5 7 TYP. A9.5 7 TYP. A9.5 1 A9.5 1 (N) CHIMNEY CRICKET A9.5 7 TYP.(N) RIDGEA9.5 10 A9.5 10 A9.5 1 A9.5 3 A9.5 3 AA R1 R2 A9.5 6 A9.5 2 SIM. A9.5 2 SIM. A9.5 7 TYP. A9.5 6 A9.5 6 A5.7 4 R5 R5 1/8" / 12" 1/8" / 12" 1/4" / 12"1/4" / 12" 22.422.4 1/4" / 12" 22.4 22.4 22.4 R1 R1 22.4 R4 1/4" / 12" +100' -0" T.O.PLATE T.O PARAPET +103' - 4" +100' -0" T.O.PLATE MATCH EXISTING PLATE 7.2 4.1 5.2 7.2 5.2 6.4 A9.5 11 TYP. A9.5 10 SIM. A9.5 14 A9.5 10 A9.5 5 A9.5 13 A9.5 13~ 5' - 0"7.1 ~ 5' - 3"7.1 7.1 7.1 7.1 A9.5 14 A9.5 15 A9.5 15 A9.5 14 PER IRC SECTION R318 - ATTIC RAFTERS ARE FULLY INSULATED TO ELIMINATE THE NEED FOR ATTIC VENTING. A. SEE SHEET A9.4/9.5 FOR TYPICAL EAVE, RAKE AND PARAPET CONDITIONS. B. FLASH ALL VALLEYS, HIPS AND CHANGE OF PLAINS IN THE ROOF WITH ZINC OR PLATED METAL EXTEND 12" MINIMUM UNDER ROOFING. C. ALL ROOF PENETRATIONS SHALL BE FLASHED AND SET IN MASTIC TO INSURE WATERPROOF SEAL AND PAINTED TO MATCH ROOFING MATERIAL. D. VERIFY ANY ELECTRICAL ITEMS AND LOCATIONS REQUESTED BY THE OWNER PRIOR TO INSTALLING ROOF MEMBRANES. E. TYPICAL ROOF PITCH VARIES - SEE ROOF PLAN. F. ALL EAVES TO BE COVERED WITH AN ICE BARRIER PER R905.1.2 THAT EXTENDS 24" MIN. FROM EXTERIOR WALL LINE OF THE BUILDING. +xx'-x" T.O. PLATE +xxxx.xx HEIGHT ABOVE FINISH FLOOR OF MAIN LEVEL FIRE SEPARATION SHEATHING APPLIED 48" MIN FROM CENTER LINE OF PARTY WALL BUILDING PER R302.2.3 SYMBOLS GENERAL ROOF NOTESROOF ASSEMBLIES XPS2 & XPS3 R-30CI, (2) 3" STAGGERED LAYERS ADHERED PER MFR RECOMMENDATIONS RAM1 HOT FLUID-APPLIED, RUBBERIZED-ASPHALT ROOFING MEMBRANE, 6125-FR BY HYDROTECH OR APPROVED EQ. R VALUE = R-13 + R-30CI 2-1/2"BALLAST1 SHEATHING PER STRUCT 2" FOAM2 R-13, VAPOR RETARDER FJ, REF STRUCT 5/8" GB1 SUB 1 GLASS-MAT GYPSUM ROOF SUBSTRATE BOARD ELD STONE FILTER FABRIC FLUID-APPLIED PMR NEW CONSTRUCTIONR1 METAL SHINGLES NEW CONSTRUCTIONR2 METAL SHINGLES EXISTING CONSTRUCTIONR3 R VALUE= R-60 SHT1 PER STRUCT SSP1 UNDER1 (E) TRUSS TOP CHORD 9 1/4"FOAM2 R-60 (E) ROOF SHEATHING R VALUE= R-60 COAT1, NOT REQ. WHERE GB1 OCCURS, REF RCPs FOR LOCATIONS SSP1 UNDER1 I-JOIST9 1/4"FOAM2 R-60 WOOD FRAMING, FLUID-APPLIED PMR, WOOD PATIO DECKING NEW CONSTRUCTIONR4 R-VALUE = R-13 + R-30CI ADJUSTABLE PEDESTALS WOOD PATIO DECKING, CPL1 CEILING, REF RCPS & SCHED ELD XPS2 & XPS3 R-30CI, STAGGERED EDGES RAM1 2" FOAM2 R-13 FJ PER STRUCT SHT1 PER STRUCT3"3"SAME AS R4, EXCEPT 2" INSUL TO SUPPORT CPL1 & NO FOAM2R5 5/8"GB1 2 3 4 5 6 7 8 9 10 F E D C B A G H 1 PROJECT NO: DATE: 20003 February 20, 2025 All reports, drawings, specifications, computer files, field data, notes, other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect, LocalElementArchitects, LLC. The Architect shall retain all common law, statutory and other reserved rights, including copyright thereto. The use of this drawing shall be restricted to the original site for which it was prepared and publication thereof is expressly limited to such use. Reuse, reproduction or publication by any method is prohibited without written consent from LocalElementArchitects, LLC. N C O A N O T F O R C O N S T R U C T IO N 2/20/2025 4:36:23 PM C:\Users\chris\OneDrive\Documents\20003--204_ S 3rd_Central_chrisTMMND.rvtSQUIRE C. KENYON LOFTS204 S. 3RD AVE.BOZEMAN MT, 59715A4.1 CONSTRUCTION ROOF PLAN NORTHSCALE: 3/16" = 1'-0"1 ROOF PLAN KEYNOTES 4.1 MASONRY WALL CAP 5.2 RAIL1, DECORATIVE METAL RAILINGS W/ WOOD RAILS, TYP. 6.4 TIMBER TRELLIS W/ ST1, TRANSPARENT STAIN FINISH, REF STRUCT 7.1 OVERFLOW ROOF SCUPPER 7.2 RDFS1, ROOF SPECIALTIES 22.4 INTERNAL ROOF DRAIN, PLUMBING TBD BY DESIGN/BUILD PLUMBER REVISIONS NO. DATE DESCRIPTION