HomeMy WebLinkAbout15--A2.8 - NOTED THIRD FLOOR PLANW/DUP
A
A5.1
A
A5.1 A6.1
2
PRIMARY
BEDROOM
4-201
PRIMARY
BATH
4-202
C.L.
4-203
OPEN TO BELOW
BEDROOM #2
3-202 A6.21
A6.2
2
A6.1 1
ELEVATOR
0-102
UNIT #4
UNIT #3
H
A5.4
H
A5.4
3-104
D
3-104
E
3-104
F
LIVING
ROOM
3-104
4-201
A
3-201
A
3-201
B
4-103
C
4-103
D
4-103
E
4-103
B
4-202
A
SDSD
I
A5.4
I
A5.4
C
A5.2
C
A5.2
B
A5.1
B
A5.1
BEDROOM #3
3-204
E
A5.2
E
A5.2
F
A5.3
F
A5.3
K
A5.4
K
A5.4
D
A5.2
D
A5.2
G
A5.3
G
A5.3
3-202
1SD
SD
3-204
A
1
1 2
3
4
5
5
6
6
BB
CC
DD
EE
FF
GG
HH
II
JJ
OPEN TO
BELOW
DINING
ROOM
4-103
LOFT
3-201
7
7
LAUNDRY
4-204
4-202
1
4-204
1
4-201
1
5.2
ATTIC
STAIRS
3-106
LIN.TUB
SHWR.
SHWR.
8
8
AA
SD
3-204
2
3-202
2
F2
3-204
1
3-203
1
BATH
3-203
22.4
22.4
6.1
6.4
T
1. REFERENCE A0.3 FOR PROJECT ABBREVIATIONS
& SYMBOLS.
2. REFERENCE A0.4 FOR BUILDING (WALL, FLOOR &
ROOF) ASSEMBLIES, AND MATERIAL & CEILING
LEGENDS.
STAIR WIDTH
TREADS & RISERS
LANDING WIDTH
HANDRAIL HEIGHT
CONTINUITY
GUARDRAIL HEIGHT
RAIL SPACING
SHALL NOT BE LESS THAN 36" IN CLEAR
WIDTH. (IBC 1011.2 EXCEPTION 1)
THE MAX. RISER HEIGHT SHALL BE 7-3/4"
(IBC 2011.5.2 EX. 3) AND THE MIN.
TREAD DEPTH SHALL BE 10". (IBC 2011.5.2
EX. 3)
SHALL NOT BE LESS THAN THE STAIRWAY
OR DOOR SERVED. EVERY LANDING
SHALL HAVE A MIN. DIM. OF 36"
MEASURED IN THE DIRECTION OF TRAVEL.
(IBC 1011.6)
SHALL BE A MIN. OF 34" AND A MAX. OF 38"
MEASURED VERTICALLY FROM THE
NOSING OF THE TREADS, AND SHALL BE
PROVIDED ON AT LEAST ONE SIDE OF
STAIRWAYS. (IBC 1014.2)
HANDRAILS FOR STAIRWAYS SHALL BE
CONTINUOUS FOR THE FULL LENGTH OF
THE FLIGHT, FROM A POINT DIRECTLY
ABOVE THE TOP RISER OF THE FLIGHT TO
A POINT DIRECTLY ABOVE THE LOWEST
RISER OF THE FLIGHT. HANDRAIL ENDS
SHALL BE RETURNED OR SHALL
TERMINATE IN NEWEL POSTS OR SAFETY
TERMINALS. HANDRAILS ADJACENT TO A
WALL SHALL HAVE A SPACE OF NOT LESS
THAN 1-1/2" BETWEEN THE WALL AND THE
HANDRAIL. (IBC 1014.4)
SHALL NOT BE LESS THAN 36". (IBC 1015.3
EX. 3)
RAILS SHALL BE SPACED SO AS NOT TO
ALLOW PASSAGE OF A SPHERE 4" IN
DIA.(IBC 1015.4)
1015.1 GENERAL
GUARDS SHALL COMPLY WITH THE PROVISION OF SECTIONS
1015.2 THROUGH 1015.7. OPERABLE WINDOWS WITH SILLS
LOCATED MORE THAN 72 INCHES ABOVE FINISHED FLOOR OR
OTHER SURFACE BELOW SHALL COMPLY WITH SECTION 1015.8
1015.8 WINDOW OPENINGS
WINDOWS IN GROUP R-2 AND R-3 BUILDINGS INCLUDING
DWELLING UNITS, WHERE THE BOTTOM OF THE CLEAR OPENING
OF AN OPERABLE WINDOWS IS LOCATED LESS THAN 36 INCHES
ABOVE THE FINISHED FLOOR AND MORE THAN 72 INCHES ABOVE
THE FINISHED FLOOR OR OTHER SURFACE BELOW ON THE
EXTERIOR OF THE BUILDING, SHALL COMPLY WITH ONE OF THE
FOLLOWING.
1. OPERABLE WINDOWS WHERE THE TOP OF THE SILL OF
THE OPENING IS LOCATED MORE THAN 75 FEET ABOVE
THE FINISHED GRADE OR OTHER SURFACE BELOW AND
THAT ARE PROVIDED WITH WINDOW FALL PREVENTION
DEVICES THAT COMPLY WITH ASTM F2006.
2. OPERABLE WINDOWS WHERE THE OPENINGS WILL NOT
ALLOW A 4-INCH DIAMETER SPHERE TO PASS THROUGH
THE OPENING WHEN THE WINDOW IS IN ITS LARGEST
OPENED POSITION.
3. OPERABLE WINDOWS WHERE THE OPENING ARE
PROVIDED WITH WINDOW FALL PREVENTION DEVICES
THAT COMPLY ASTM F2090.
4. OPERABLE WINDOWS THAT ARE PROVIDED WITH
WINDOW OPENING CONTROL DEVICES THAT COMPLY
WITH SECTION 1015.8.1.
1015.8 WINDOW OPENINGS
WINDOW OPENING CONTROL DEVICES SHALL COMPLY WITH
ASTM F2090. THE WINDOW OPENING CONTROL DEVICE, AFTER
OPERATION TO RELEASE THE CONTROL DEVICE ALLOWING THE
WINDOW TO FULLY OPEN, SHALL NOT REDUCE THE MINIMUM NET
CLEAR OPENING AREA OF THE WINDOW UNIT TO LESS THE AREA
REQUIRED BY SECTION 1031.3.1
110 PERMANENTLY WIRED, INTERCONNECTED
SMOKE DETECTOR WITH BATTERY BACKUP AND
CARBON MONIXIDE ALARM
SD
FP-1 36" W x 28" H x 28" D 33'-0" 14"
FP-2 36" W x 28" H x 28" D 23'-0" 14"
FP# W x H x D HEIGHT FLUE SIZE
ALL FIREPLACES TO BE ISOKERN MAGNUM SERIES (ICC-
ESR-2316)
EACH FIREPLACE SHALL BE PROVIDED WITH AN EXTERIOR
COMBUSTION AIR PIPE 4" DIA. AIR INTAKE SHALL NOT BE
LOCATED AT AN ELEVATION HIGHER THAN THE FIREBOX. EACH
FIREPLACE SHALL CONTAIN A PERMANENTLY INSTALLED GAS
LOG SET WITH ELECTRONIC START LOCATED BY THE OWNER.
PROVIDE GAS SHUT-OFF VALVE WITHIN 6 FEET OF THE
FIREPLACE PER IFGC G2420. VERIFY LOCATION W/ OWNER.
TOP OF CHIMNEYS SHALL EXTEND A MINIMUM OF 2'-0" ABOVE ANY
PORTION OF THE ROOF WITHIN A 10'-0" RADIUS.
COMBUSTIBLE MATERIAL SHALL NOT BE PLACED WITHIN 2" OF
FIREPLACES, SMOKE CHAMBER OR CHIMNEY WALLS.
COMBUSTIBLE MATERIAL SHALL NOT BE PLACED WITHIN 6" OF
THE FIREPLACE OPENING. NO SUCH COMBUSTIBLE MATERIAL
WITHIN 12" OF THE FIREPLACE OPENING SHALL PROJECT MORE
THAN 1/8" FOR EACH 1" DISTANCE FROM SUCH OPENING.
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
G
H
1
PROJECT NO:
DATE:
20003
February 20, 2025
All reports, drawings, specifications, computer
files, field data, notes, other documents and
instruments prepared by the Architect as
instruments of service shall remain the property
of the Architect, LocalElementArchitects, LLC.
The Architect shall retain all common law,
statutory and other reserved rights, including
copyright thereto. The use of this drawing shall
be restricted to the original site for which it was
prepared and publication thereof is expressly
limited to such use. Reuse, reproduction or
publication by any method is prohibited without
written consent from LocalElementArchitects,
LLC.
N C O A
N O T F O R C O N S T R U C T IO N
2/20/2025 4:35:46 PM C:\Users\chris\OneDrive\Documents\20003--204_ S 3rd_Central_chrisTMMND.rvtSQUIRE C. KENYON LOFTS204 S. 3RD AVE.BOZEMAN MT, 59715A2.8
NOTED THIRD
FLOOR PLAN
SCALE: 3/16" = 1'-0"1 NOTED THIRD FLOOR
NORTH5.2 RAIL1, DECORATIVE METAL RAILINGS W/ WOOD RAILS, TYP.
6.1 INTERIOR WOOD STAIRS & RAILINGS
6.4 TIMBER TRELLIS W/ ST1, TRANSPARENT STAIN FINISH, REF
STRUCT
22.4 INTERNAL ROOF DRAIN, PLUMBING TBD BY DESIGN/BUILD
PLUMBER
KEYNOTES
DRAWING NOTES
NAME AREA
CIRCULATION
BASEMENT CIRCULATION ADDITION 390 SF
CIRCULATION ADDITION 118 SF
MAIN LEVEL ADDITION 241 SF
CIRCULATION: 3 748 SF
COVERED PATIO
BASEMENT PATIO 124 SF
BASEMENT PATIO 162 SF
MAIN FLOOR PATIO ADDITION 122 SF
REMODELED PATIO 171 SF
SECOND FLOOR PATIO ADDITION 124 SF
COVERED PATIO: 5 704 SF
GARAGE/MECH.
BASEMENT GARAGE ADDITION 1,647 SF
GARAGE/MECH.: 1 1,647 SF
LIVABLE ADDITION
BASEMENT LIVABLE ADDITION 95 SF
MAIN LEVEL ADDITION 558 SF
SECOND FLOOR ADDITION 566 SF
SECOND FLOOR ADDITION 82 SF
THIRD LEVEL ADDITION 293 SF
THIRD LEVEL ADDITION 67 SF
LIVABLE ADDITION: 6 1,662 SF
LIVABLE REMODEL
BASEMENT REMODEL 1,447 SF
MAIN LEVEL REMODEL 1,632 SF
SECOND FLOOR REMODEL 1,737 SF
THIRD LEVEL REMODEL 1,126 SF
LIVABLE REMODEL: 4 5,942 SF
TOTAL UNDER ROOF 10,703 SF
SQUARE FOOTAGES
STAIR AND HANDRAIL NOTES
WINDOW FALL PROTECTION
SMOKE DETECTOR
FIREBOX AND CHIMNEY SIZING
REVISIONS
NO. DATE DESCRIPTION