Loading...
HomeMy WebLinkAbout12--A2.5 - NOTED BASEMENT FLOOR PLANUP UPWD UP UP DN UP WD#1 A A5.1 A A5.1 AD6.1 1 AD6.13 AD6.1 4 A6.21 A6.1 1 1/8" / 12"1/8" / 12"MECH. 2-003 F.F. +88' - 11" MUDROOM 1-002 MECH. 1-003 PRIMARY BEDROOM #2 1-004 PRIMARY BATH #2 1-005 C.L. #2 1-006 OWNER ENTRY 2-0021/8" / 12"1/8" / 12"1/8" / 12"1/8" / 12"LAUNDRY 2-005 VEST. 2-006 BEDROOM #2 2-007 C.L. #2 2-008 BATH #2 2-009 PRIMARY BEDROOM 2-010 PRIMARY BATH 2-011 UNIT 1 PATIO 1-007 UNIT 2 PATIO 2-016 HALLWAY 001 PUMP RM 002 ELEVATOR 0-102 PLANTERBENCHBENCHPLANTERUNIT #1 UNIT #2 H A5.4 H A5.4 1-003 1 2-008 2 2-009 1 2-007 1 2-002 2 4-001 1 3-001 1 3-001 1 4-001 1 2-001 1 1-001 1 T.O. WALL +93' - 4" T.O. BENCH +92' - 1 1/2" T.O. WALL +91' - 10" T.O. BENCH +90' - 0" 4" 4" SD SD SD I A5.4 I A5.4 C A5.2 C A5.2 B A5.1 B A5.1 2-010 4 2-010 3 2-010 2 2-010 1 1-004 1 WS WS WT WH WHWT WH ENTRY STAIRS 101 J A5.4 J A5.4 E A5.2 E A5.2 F A5.3 F A5.3 K A5.4 K A5.4 D A5.2 D A5.2 G A5.3 G A5.3 28.1 1-002 1 1-005 1 2-003 1 2-002 1 WATER ENTRANCE 003 002 1 0-003 1 2-010 5 2-007 2 1-004 2 4"4"4"4"1 1 2 3 4 5 5 6 6 BB CC DD EE FF GG HH II JJ F.F. 90' - 4" 7 7 22.1 22.1 2-011 1 22.122.1 F.F. 91' - 6"F.F. 91' - 6" F.F. 90' - 4" SD SDPLANTER 8 8 W.C. 2-012 T T T T T T T AA A5.6 4 A5.5A 2 A5.10A 2A5.6A 2 UNIT 1 GARAGE 1-001 UNIT 2 GARAGE 2-001 UNIT 3 GARAGE 3-001 UNIT 4 GARAGE 4-001 101 0 2-008 1 A9.4 12 6.1 6.1 6.1 6.1 6.1 22.1 3.2 3.2 3.23.2 5.2 5.2 5.2 3.4 3.4 8.2 8.2 4.14 4.14 4.14 1. REFERENCE A0.3 FOR PROJECT ABBREVIATIONS & SYMBOLS. 2. REFERENCE A0.4 FOR BUILDING (WALL, FLOOR & ROOF) ASSEMBLIES, AND MATERIAL & CEILING LEGENDS. STAIR WIDTH TREADS & RISERS LANDING WIDTH HANDRAIL HEIGHT CONTINUITY GUARDRAIL HEIGHT RAIL SPACING SHALL NOT BE LESS THAN 36" IN CLEAR WIDTH. (IBC 1011.2 EXCEPTION 1) THE MAX. RISER HEIGHT SHALL BE 7-3/4" (IBC 2011.5.2 EX. 3) AND THE MIN. TREAD DEPTH SHALL BE 10". (IBC 2011.5.2 EX. 3) SHALL NOT BE LESS THAN THE STAIRWAY OR DOOR SERVED. EVERY LANDING SHALL HAVE A MIN. DIM. OF 36" MEASURED IN THE DIRECTION OF TRAVEL. (IBC 1011.6) SHALL BE A MIN. OF 34" AND A MAX. OF 38" MEASURED VERTICALLY FROM THE NOSING OF THE TREADS, AND SHALL BE PROVIDED ON AT LEAST ONE SIDE OF STAIRWAYS. (IBC 1014.2) HANDRAILS FOR STAIRWAYS SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT, FROM A POINT DIRECTLY ABOVE THE TOP RISER OF THE FLIGHT TO A POINT DIRECTLY ABOVE THE LOWEST RISER OF THE FLIGHT. HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEWEL POSTS OR SAFETY TERMINALS. HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPACE OF NOT LESS THAN 1-1/2" BETWEEN THE WALL AND THE HANDRAIL. (IBC 1014.4) SHALL NOT BE LESS THAN 36". (IBC 1015.3 EX. 3) RAILS SHALL BE SPACED SO AS NOT TO ALLOW PASSAGE OF A SPHERE 4" IN DIA.(IBC 1015.4) 1015.1 GENERAL GUARDS SHALL COMPLY WITH THE PROVISION OF SECTIONS 1015.2 THROUGH 1015.7. OPERABLE WINDOWS WITH SILLS LOCATED MORE THAN 72 INCHES ABOVE FINISHED FLOOR OR OTHER SURFACE BELOW SHALL COMPLY WITH SECTION 1015.8 1015.8 WINDOW OPENINGS WINDOWS IN GROUP R-2 AND R-3 BUILDINGS INCLUDING DWELLING UNITS, WHERE THE BOTTOM OF THE CLEAR OPENING OF AN OPERABLE WINDOWS IS LOCATED LESS THAN 36 INCHES ABOVE THE FINISHED FLOOR AND MORE THAN 72 INCHES ABOVE THE FINISHED FLOOR OR OTHER SURFACE BELOW ON THE EXTERIOR OF THE BUILDING, SHALL COMPLY WITH ONE OF THE FOLLOWING. 1. OPERABLE WINDOWS WHERE THE TOP OF THE SILL OF THE OPENING IS LOCATED MORE THAN 75 FEET ABOVE THE FINISHED GRADE OR OTHER SURFACE BELOW AND THAT ARE PROVIDED WITH WINDOW FALL PREVENTION DEVICES THAT COMPLY WITH ASTM F2006. 2. OPERABLE WINDOWS WHERE THE OPENINGS WILL NOT ALLOW A 4-INCH DIAMETER SPHERE TO PASS THROUGH THE OPENING WHEN THE WINDOW IS IN ITS LARGEST OPENED POSITION. 3. OPERABLE WINDOWS WHERE THE OPENING ARE PROVIDED WITH WINDOW FALL PREVENTION DEVICES THAT COMPLY ASTM F2090. 4. OPERABLE WINDOWS THAT ARE PROVIDED WITH WINDOW OPENING CONTROL DEVICES THAT COMPLY WITH SECTION 1015.8.1. 1015.8 WINDOW OPENINGS WINDOW OPENING CONTROL DEVICES SHALL COMPLY WITH ASTM F2090. THE WINDOW OPENING CONTROL DEVICE, AFTER OPERATION TO RELEASE THE CONTROL DEVICE ALLOWING THE WINDOW TO FULLY OPEN, SHALL NOT REDUCE THE MINIMUM NET CLEAR OPENING AREA OF THE WINDOW UNIT TO LESS THE AREA REQUIRED BY SECTION 1031.3.1 110 PERMANENTLY WIRED, INTERCONNECTED SMOKE DETECTOR WITH BATTERY BACKUP AND CARBON MONIXIDE ALARM SDFP-1 36" W x 28" H x 28" D 33'-0" 14" FP-2 36" W x 28" H x 28" D 23'-0" 14" FP# W x H x D HEIGHT FLUE SIZE ALL FIREPLACES TO BE ISOKERN MAGNUM SERIES (ICC- ESR-2316) EACH FIREPLACE SHALL BE PROVIDED WITH AN EXTERIOR COMBUSTION AIR PIPE 4" DIA. AIR INTAKE SHALL NOT BE LOCATED AT AN ELEVATION HIGHER THAN THE FIREBOX. EACH FIREPLACE SHALL CONTAIN A PERMANENTLY INSTALLED GAS LOG SET WITH ELECTRONIC START LOCATED BY THE OWNER. PROVIDE GAS SHUT-OFF VALVE WITHIN 6 FEET OF THE FIREPLACE PER IFGC G2420. VERIFY LOCATION W/ OWNER. TOP OF CHIMNEYS SHALL EXTEND A MINIMUM OF 2'-0" ABOVE ANY PORTION OF THE ROOF WITHIN A 10'-0" RADIUS. COMBUSTIBLE MATERIAL SHALL NOT BE PLACED WITHIN 2" OF FIREPLACES, SMOKE CHAMBER OR CHIMNEY WALLS. COMBUSTIBLE MATERIAL SHALL NOT BE PLACED WITHIN 6" OF THE FIREPLACE OPENING. NO SUCH COMBUSTIBLE MATERIAL WITHIN 12" OF THE FIREPLACE OPENING SHALL PROJECT MORE THAN 1/8" FOR EACH 1" DISTANCE FROM SUCH OPENING. 2 3 4 5 6 7 8 9 10 F E D C B A G H 1 PROJECT NO: DATE: 20003 February 20, 2025 All reports, drawings, specifications, computer files, field data, notes, other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect, LocalElementArchitects, LLC. The Architect shall retain all common law, statutory and other reserved rights, including copyright thereto. The use of this drawing shall be restricted to the original site for which it was prepared and publication thereof is expressly limited to such use. Reuse, reproduction or publication by any method is prohibited without written consent from LocalElementArchitects, LLC. N C O A N O T F O R C O N S T R U C T IO N 2/20/2025 4:33:31 PM C:\Users\chris\OneDrive\Documents\20003--204_ S 3rd_Central_chrisTMMND.rvtSQUIRE C. KENYON LOFTS204 S. 3RD AVE.BOZEMAN MT, 59715A2.5 NOTED BASEMENT FLOOR PLAN SCALE: 3/16" = 1'-0"1 NOTED BASEMENT FLOOR PLAN NAME AREA CIRCULATION BASEMENT CIRCULATION ADDITION 390 SF CIRCULATION ADDITION 118 SF MAIN LEVEL ADDITION 241 SF CIRCULATION: 3 748 SF COVERED PATIO BASEMENT PATIO 124 SF BASEMENT PATIO 162 SF MAIN FLOOR PATIO ADDITION 122 SF REMODELED PATIO 171 SF SECOND FLOOR PATIO ADDITION 124 SF COVERED PATIO: 5 704 SF GARAGE/MECH. BASEMENT GARAGE ADDITION 1,647 SF GARAGE/MECH.: 1 1,647 SF LIVABLE ADDITION BASEMENT LIVABLE ADDITION 95 SF MAIN LEVEL ADDITION 558 SF SECOND FLOOR ADDITION 566 SF SECOND FLOOR ADDITION 82 SF THIRD LEVEL ADDITION 293 SF THIRD LEVEL ADDITION 67 SF LIVABLE ADDITION: 6 1,662 SF LIVABLE REMODEL BASEMENT REMODEL 1,447 SF MAIN LEVEL REMODEL 1,632 SF SECOND FLOOR REMODEL 1,737 SF THIRD LEVEL REMODEL 1,126 SF LIVABLE REMODEL: 4 5,942 SF TOTAL UNDER ROOF 10,703 SF SQUARE FOOTAGES NORTH3.2 4" CURB STOP 3.4 4" DEPRESS SLAB FOR FLOOR DRAIN, SHOWER PAN 4.14 MASONRY CONTROL JOINT, 1/2" SEALANT, PROVIDE 20' MAX. SPACING BETWEEN JOINTS & REVIEW LOCATIONS FOR APPROVAL W/ ARCHITECT PRIOR TO INSTALL 5.2 RAIL1, DECORATIVE METAL RAILINGS W/ WOOD RAILS, TYP. 6.1 INTERIOR WOOD STAIRS & RAILINGS 8.2 2'-4" WIDE 1/2" THICK TEMPERED GLASS SHOWER DOOR ENCLOSURE 22.1 TRENCH DRAIN, REF CIVIL & PLUMBING 28.1 FIRE ALARM KEYNOTES DRAWING NOTESSTAIR AND HANDRAIL NOTES WINDOW FALL PROTECTION SMOKE DETECTORFIREBOX AND CHIMNEY SIZING REVISIONS NO. DATE DESCRIPTION