HomeMy WebLinkAbout08--AD2.2 - DEMOLITION FLOOR PLANSUP
UP
UP
UP
UP
EXISTING
BEDROOM
EXISTING
BEDROOM
EXISTING
BEDROOM
EXISTING
BEDROOM
EXISTING
STAIRS
EXISTING
BATH
EXISTING
HALL
D1.13
D1.13
D1.12
D1.12
D1.12
D1.2
D1.19
D1.13
D1.10
D1.9
D1.11
D1.11
D1.16
3' - 7 5/8"3' - 2 3/4"7' - 10 1/4"1
1 2
3 4
4
5
5
6
6
D
E
F
G
H
I
J
D2.21
D2.21
D2.21
EXISTING
KITCHEN EXISTING BEDROOM
EXISTING
DINING ROOM
EXISTING
LIVING ROOM
EXISTING
STAIRS
EXISTING
BATHROOM
AD6.1 1
AD6.1
4
A6.1 1
D1.17
D1.11
D1.11
D1.10
D1.9
D1.9
D1.2
D1.12
D1.16
10' - 6 1/8"15' - 4 1/8"12' - 1"1
1 2
3 4
4
5
5
6
6
D
E
F
G
H
I
J
EXISTING WALL TO REMAIN
EXISTING WALL/ELEMENT TO BE DEMOLISHED
EXISTING DOOR TO REMAIN
EXISTING DOOR TO BE DEMOLISHED
EXISTING WALL/ELEMENT TO BE DEMOLISHED
A. PROTECT ALL FLOORING, WALLS AND MATERIALS
THAT ARE TO REMAIN DURING DEMOLITION AND
CONSTRUCTION.
B. PROTECT TO THE EXTENT POSSIBLE ALL LANDSCAPE
AND SITEWORK THAT IS TO REMAIN DURING
DEMOLITION AND CONSTRUCTION.
C. ALL EXTERIOR WINDOWS AND DOORS ARE TO BE
REPLACED - PROTECT ROUGH OPENING FOR RE-
INSTALLATION.
D. DO NOT ALTER THE STRUCTURAL INTEGRITY OF THE
EXISTING STRUCTURE OR IT'S ASSEMBLIES UNLESS
SPECIFICALLY NOTED OTHERWISE. PROTECT
COLUMNS AND OTHER STRUCTURAL ELEMENTS
DURING DEMOLITION AND CONSTRUCTION.
E. VERIFY WITH OWNER ALL ITEMS THAT ARE SHOWN ON
THE DEMO PLAN TO BE REMOVED PRIOR TO
REMOVING OR DEMOLITION.
F. PROMPTLY REMOVE ALL MATERIAL AND DEBRIS
REMOVED DURING DEMOLITION FROM THE PROPERTY,
AND DISPOSE OF THEM IN ACCORDANCE WITH LOCAL
ORDINANCES.
G. SECURE THE PROPERTY TO THE EXTENT POSSIBLE
DURING DEMOLITION.
H. UPON COMPLETION OF DEMOLITION, PATCH AND
REPAIR ALL EXISTING SURFACES, OPENINGS, AND
ROOF PENETRATIONS.
I. EXISTING MATERIALS SHALL BE PROTECTED FROM
DAMAGE AT ALL TIMES. EXISTING BUILDING MATERIALS
AND/OR FINISHES THAT ARE DAMAGED SHALL BE
REPAIRED AND/OR REPLACED AND APPROVED BY THE
OWNER/ARCHITECT AT NO ADDITIONAL COST.
J. IF HAZARDOUS MATERIALS SUCH AS ASBESTOS ARE
ENCOUNTERED, CEASE WORK AND IMMEDIATELY
NOTIFY THE OWNER AND CONSTRUCTION MANAGER
WHO WILL ARRANGE APPROPRIATE MITIGATION. DO
NOT COMMENCE WORK UNTIL MITIGATION IS
CERTIFIED.
K. DEMO AND REPLACE ANY WATER DAMAGED, ROTTEN,
MOLDY OR STRUCTURALY COMPRISED FRAMING,
SHEATHING, OR BLOCKING. NOTIFY OWNER &
ARCHITECT IF ANY DAMAGED AREAS ARE FOUND.
L. REMOVE AND DISCARD ALL EXISTING INTERIOR
FINISHES TO EXPOSE WOOD STUD FRAMING/
SHEATHING/ JOISTS.
M. DEMOLISH ALL EXISTING CEILINGS FOR CONTRACTOR
CONVENIENCE TO INSTALL NEW BUILDING SYSTEMS
UNLESS OTHERWISE DIRECTED BY OWNER.
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
G
H
1
PROJECT NO:
DATE:
20003
February 20, 2025
All reports, drawings, specifications, computer
files, field data, notes, other documents and
instruments prepared by the Architect as
instruments of service shall remain the property
of the Architect, LocalElementArchitects, LLC.
The Architect shall retain all common law,
statutory and other reserved rights, including
copyright thereto. The use of this drawing shall
be restricted to the original site for which it was
prepared and publication thereof is expressly
limited to such use. Reuse, reproduction or
publication by any method is prohibited without
written consent from LocalElementArchitects,
LLC.
N C O A
N O T F O R C O N S T R U C T IO N
2/20/2025 4:44:08 PM C:\Users\chris\OneDrive\Documents\20003--204_ S 3rd_Central_chrisTMMND.rvtSQUIRE C. KENYON LOFTS204 S. 3RD AVE.BOZEMAN MT, 59715AD2.2
DEMOLITION FLOOR
PLANS
SCALE: 3/16" = 1'-0"2 DEMOLITION SECOND FLOOR PLAN
SCALE: 3/16" = 1'-0"1 DEMOLITION THIRD FLOOR PLAN
NORTHDEMO LEGEND
DEMO NOTES
D1.2 DEMOLISH AND DISCARD EXISTING FIRE ESCAPE
D1.9 DEMOLISH EXISTING PARTITION WALL - SHORE OR
REPLACE WITH BEAM PER STRUCTURE
D1.10 DEMOLISH AND DISCARD EXISTING FIREPLACE AND
CHIMNEY - REINFORCE PER STRUCTURE
D1.11 DEMOLISH EXISTING WALL - PROTECT AND RE-USE
EXISTING BRICK
D1.12 DEMOLISH EXISTING STAIRS
D1.13 REMOVE AND RESTORE RADIATOR HEATERS
D1.16 DEMOLISH AND DISCARD EXISTING PLUMBING
FIXTURE
D1.17 DEMOLISH AND DISCARD EXISTING ROOF
STRUCTURE - SHORE PER STRUCTURE
D1.19 DEMOLITION AND DISCARD EXISTING WINDOWS -
KEEP LEADED GLASS WINDOWS AND ONE
ASSEMBLY FOR EVERY TYPE OF WINDOW TO SEND
TO WINDOW MANFACTURER FOR RECREATION.
D2.21 DEMOLISH EXISTING FLOOR DIAPHRAM - PROTECT
AND SAVE FRAMING MEMBERS/T&G WOOD FLOOR IF
POSSIBLE AND CORDINATE RE-USE WITH
ARCHITECT
KEYNOTES
REVISIONS
NO. DATE DESCRIPTION