HomeMy WebLinkAbout037 L301 OVERALL IRRIGATIONCLKMW20.32110.671POCLATERAL DRIP LINES, TYP.PVC SLEEVING, TYP.DRIP RINGS TO PROPOSED TREE& ZONED SEPARATELY, TYP.FLUSH VALVES AT ENDS/LOWPOINTS OF DRIP LINES, TYP.WIRELESS RAIN/FREEZE SENSORMOUNTED TO EXTERIOR OF BLDG.LOCATION TBD.POINT OF CONNECTION,LOCATED IN MECHANICALROOM. TAP & SET 3/4" WATER METER.COORDINATE WITHMECHANICAL AND ELECTRICAL.IRRIGATION CONTROLLERPROPOSED QUICK COUPLERFOR WINTERIZATION BLOWOUTS.BFFF1"FSPROPOSED MAINLINE, TYP.(INSTALL MAINLINE & SLEEVING PRIOR TOPAVER & CONCRETE INSTALLATION.INSTALL VALVE BOXES AT SLEEVINGCHANGES IN DIRECTION AS NEEDED).IRRIGATION GENERAL NOTES1.PRIOR TO COMMENCING ANY WORK, APPLICANT MUST CONTACT THE WATER CONSERVATIONDIVISION TO SCHEDULE A PRE-INSTALLATION MEETING.2.A BACKFLOW PREVENTER SHALL BE PROFESSIONALLY INSTALLED AS PER THE CITY OF BOZEMANREQUIREMENTS.3.IRRIGATION CONTROLLERS LABELED BY U.S. EPA WATERSENSE® PROGRAM ARE REQUIRED.4.IRRIGATION CONTRACTOR SHALL INSTALL A RAINBIRD (OR SIMILAR) WEATHER SENSOR WHEREAPPROPRIATE.5.CONTRACTOR TO INSTALL CONTROLLER AND ACCESSORIES AS REQUIRED. CONTROL WIRES ANDVALVES TO CONTROLLER TO BE FURNISHED BY CONTRACTOR.6.CONTRACTOR TO COORDINATE WITH EXISTING ELECTRICAL FOR CONTROLLER CONNECTION.7.INSTALLED SYSTEM TO BE FULLY WINTERIZEABLE. CONTRACTOR TO PROVIDE OWNERSWINTERIZATION PLAN.8.IRRIGATION POC WILL BE CONNECTED TO CITY SERVICE.9.IRRIGATION DESIGN ASSUMES 16 GPM AVAILABLE FROM WATER SOURCE AND 65 PSI STATICPRESSURE.10.CONTRACTOR TO VERIFY STATIC PRESSURE ON SITE PRIOR TO BIDDING AND CONSTRUCTION.11.CARE SHALL BE TAKEN TO ENSURE IRRIGATION SYSTEM IS INSTALLED PROPERLY TOMINIMIZE/ELIMINATE WATER WASTE DUE TO OVER SPRAY ONTO HARDSCAPE SURFACES.12.MAINLINE SHALL BE TRENCHED. PROVIDE POSITIVE DRAINAGE. PLACE MANUAL DRAIN AT LOWPOINTS IN MAINLINE. IDENTIFY LOCATIONS ON AS-BUILTS.13.THRUST BLOCKS TO BE INSTALLED AT ALL MAINLINE CHANGES IN DIRECTION.14.INSTALL ALL IRRIGATION PIPE AND CONTROL WIRES IN PVC SLEEVES BELOW ALL PAVED SURFACES.INSTALL SLEEVES PRIOR TO PLACEMENT OF PAVEMENT AND SUB-BASE.15.CONTRACTOR MAY NOT DECREASE PIPE SIZE SHOWN ON PLAN. A LARGER PIPE SIZE MAY BE USEDWITH AN ADDITIONAL COST TO OWNER.16.ALL LANDSCAPE BEDS TO RECEIVE DRIP IRRIGATION. HIGH EFFICIENCY DRIP IRRIGATION ZONESSHALL HAVE 1 GALLON/HR EMITTERS TO ALL PERENNIALS AND GRASSES.17.ALL TREES SHALL BE IRRIGATED WITH HIGH EFFICIENCY DRIP RINGS AND ZONED SEPARATELY FROMSHRUBS, PERENNIALS, AND GRASSES.18.ALL ZONES MUST BE SEPARATED BASED ON HYDROZONES SHOWN ON PLAN.19.ON THE NORTH SIDES OF STRUCTURES OR HEAVY CLAY SOILS, CARE SHALL BE TAKEN TOMINIMIZE OVER WATERING DEPENDING ON SOIL CONDITIONS AND THE SIZE OF EMITTER MAY BEREDUCED.20.CONTRACTOR RESPONSIBLE FOR PROVIDING OWNER WITH IRRIGATION AS-BUILTS AT COMPLETIONOF INSTALLATION.21.CONTRACTOR RESPONSIBLE TO INFORM LANDSCAPE ARCHITECT OF ANY DISCREPANCIES ORCHANGES NEEDED TO IRRIGATION DESIGN. IF LANDSCAPE ARCHITECT WAS NOT INFORMED OF ANYCHANGES CONTRACTOR ASSUMES FULL RESPONSIBILITY OF SYSTEM FUNCTIONALITY.22.CONTRACTOR TO COORDINATE IRRIGATION WITH THE PLANTING PLAN AND SITE IMPROVEMENTS.23.ALL IRRIGATION COMPONENTS TO BE INSTALLED PER MANUFACTURER RECOMMENDATIONS.C.O.B - ANNUAL IRRIGATION WATER REQUIREMENT (IWR)6<0%2/0$18)$&785(502'(/'(6&5,37,2147<Rain Bird XCZ-100-LCWide Flow Drip Control Kit, for Light Commercial Uses. 1in.PEB Valve, with 1in. Pressure Regulating 40psi Basket Filter.0.3-20 GPM.2Rain Bird MDCFCAP (or similar)Dripline Flush Valve cap in compression fitting coupler.2Rain Bird XFCV-09-12 Drip Ring (or similar)1Area to Receive Drip EmittersRain Bird XB-PC (or similar)Single Outlet, Pressure Compensating Drip Emitters. Flowrates of 1.0 GPH=black, and 2.0 GPH=red. Comes with aself-piercing barb inlet x barb outlet.89.0 s.f.Emitter Notes:10PC emitters (2 assigned to each 1 gal plant)3220PC emitters (2 assigned to each 5 gal plant)20PC emitters (2 assigned to each 10 gal plant)6<0%2/0$18)$&785(502'(/'(6&5,37,2147<Rain Bird 3-RC (or similar)3/4in. Brass Quick-Coupling Valve, with Corrosion-ResistantStainless Steel Spring, Thermoplastic Rubber Cover, and1-Piece Body.1Landscape Products Inc. BGV (or similar)1/2in., 3/4in., 1in., 1-1/4in., 1-1/2in., 2in., 2-1/2in., 3in.,4in. Brass Gate Valve. Threaded bonnet, Non-rising stem,Pressure rated to 200 psi. Same size as mainline.1Rain Bird EFB-CP-PRS-D 1"1in., 1-1/4”, 1-1/2in., 2in. Brass Master Valve, that isContamination Proof w/Self-Flushing Filter Screen. GlobeConfiguration, Reclaimed Water Compatible, and PurpleHandle Cover Designates Non-Potable Water Use. WithPressure Regulator.1Febco 825Y (or similar) 3/4"Reduced Pressure Backflow Preventer1Rain Bird ESP4ME34 Station, Hybrid Modular Outdoor Controller. ForResidential or Light Commercial Use. LNK WiFi Module andFlow Sensor Ready.1Rain Bird LNK2WIFIUpgrades Controller to Have Weather Data for ET-BasedAdjustments (WaterSense Approved) & WiFi Capabilities1Rain Bird WR2-RFSWireless Rain/Freeze Sensor.1Rain Bird FS-150-P1-1/2in. Flow Sensor, Plastic PVC Model. SuggestedOperating Range 5.0 GPM to 100.0 GPM. Size for Flow NotAccording to Pipe Size. Rain Bird Compatible Controllers:ESP-LXIVM(P) | LXD | LXME2(P) | ME3, or ControllersAccepting Custom K-Factor and Offset. Install in Rain BirdValve Box.13/4" Water MeterCity Service1Irrigation Lateral Line: 60 PE Drip Line - 1/2"(or similar)34.6 l.f.Irrigation Mainline: PVC Schedule 40 - 1"110.0 l.f.Pipe Sleeve: PVC Schedule 40Twice the aggregate diameter of all pipe and wire in sleeve16.9 l.f.FMBFCLKWFSPOCValve NumberValve FlowValve SizeValve Callout###",55,*$7,216&+('8/(Generated:2024-12-23 11:38P.O.C. NUMBER: 01Water Source Information:City ServiceFLOW AVAILABLECustom Max Flow:16 GPMFlow Available16 GPMPRESSURE AVAILABLEStatic Pressure at POC:65 PSIPressure Available:65 PSIDESIGN ANALYSISMaximum Station Flow:0.67 GPMFlow Available at POC:16 GPMResidual Flow Available:15.33 GPMCritical Station:1 Design Pressure:40 PSI Friction Loss:0 PSI Fittings Loss:0 PSI Elevation Loss:0 PSI Loss through Valve:7 PSIPressure Req. at Critical Station:47.0 PSILoss for Fittings:0.0 PSILoss for Main Line:0.02 PSILoss for POC to Valve Elevation:0 PSILoss for Backflow:11 PSILoss for Master Valve:0.2 PSICritical Station Pressure at POC:58.2 PSIPressure Available:65 PSIResidual Pressure Available:6.78 PSI&5,7,&$/$1$/<6,6180%(502'(/7<3(35(&,368102178(:('7+8)5,6$7,1.:((.0,1.:((.*$/.:((.*$/.'$<1Rain Bird XCZ-100-LCArea for Drip Emitters1.01 in/h9 min9 min9 min0.442718.05.992Rain Bird XCZ-100-LCDrip Ring1.07 in/h17 min17 min17 min0.864915.45.15TOTALS:2626267633.411.1:$7(5,1*6&+('8/(0SCALE: feet1020301" = 10'SCALE: 1"=10'-0"OVERALL IRRIGATION PLANL301DATE:JOB NO.DRAWN BY:CHECKED BY:SCALE:LANDSCAPE ARCHITECT:OUTDOOR DESIGN STUDIOSALY ROSS3084 THORPE ROADBELGRADE, MT 597141" = 10'No.DescriptionDateDRAWING TITLE:SHEET NO.THE CONTRACTOR IS RESPONSIBLEFOR MATERIALS, DETAILS ANDACCURACY, FOR CONFIRMING ANDCORRELATING ALL QUANTITIES ANDDIMENSIONS, FOR SELECTINGFABRICATION PROCESSES, FORTECHNIQUES OF ASSEMBLY, FORPERFORMING WORK IN A SAFE MANNER,AND FOR COORDINATING WORK WITHTHAT OF ALL TRADES.COPYRIGHT 2024, ATELIER MEY ARCHITECTS, LLC.FIRE PROTECTION:SUMMIT FIRE & SECURITYJOE BURTELLCIVIL:ALLIED ENGINEERING SERVICES, INC.RORY ROMEY32 DISCOVERY DRIVEBOZEMAN, MT 59718MEP:WILLIAMS ENGINEERINGRYAN SULLIVAN370 COMPANION WAYBELGRADE, MT 59714STRUCTURAL:BRITT, PETERS & ASSOCIATESDAVID IMPSON1435 W MOREHEAD ST. SUITE 140CHARLOTTE, NC 28208OVERALLIRRIGATIOND O N O T S C A L E D R A W I N G S ,C O N T A C T A R C H I T E C T S W I T H Q U E S T I O N S
ARCHITECT:ATELIER MEY ARCHITECTS3642 WILLIAM AVEMIAMI FL 33133T: 612.414.7670LIC AR99741 [SHAWNA MEYER]OWNER:MISSOURI HEIGHTSSTEFFANIE HARING, JUSTIN HARING4600 SOURDOUGH RDBOZEMAN, MT 59715417-288-1328CONTRACTOR:080 April 11, 2025JDARDesign Development11 April, 2025
703 W Mendenhall
703 W Mendenhall Street
Bozeman, MT 59715N W. MENDENHALL ST.N. 7TH AVE.PROPOSED BUILDINGCOVEREDPARKINGCOVEREDPARKINGPROPERTY LINE PROPERTY LINEOPENSPACE