Loading...
HomeMy WebLinkAbout011 A-0 COVERDATE:JOB NO.DRAWN BY:CHECKED BY:SCALE:LANDSCAPE ARCHITECT:OUTDOOR DESIGN STUDIOSALY ROSS3084 THORPE ROADBELGRADE, MT 59714DRAWING TITLE:SHEET NO.THE CONTRACTOR IS RESPONSIBLE FOR MATERIALS, DETAILS AND ACCURACY, FOR CONFIRMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS, FOR SELECTING FABRICATION PROCESSES, FOR TECHNIQUES OF ASSEMBLY, FORPERFORMING WORK IN A SAFE MANNER, AND FOR COORDINATING WORK WITH THAT OF ALL TRADES.COPYRIGHT 2024, ATELIER MEY ARCHITECTS, LLC.FIRE PROTECTION:SUMMIT FIRE & SECURITYJOE BURTELLCIVIL:ALLIED ENGINEERING SERVICES, INC. RORY ROMEY32 DISCOVERY DRIVEBOZEMAN, MT 59718MEP:WILLIAMS ENGINEERINGRYAN SULLIVAN370 COMPANION WAYBELGRADE, MT 59714STRUCTURAL:BRITT, PETERS & ASSOCIATESDAVID IMPSON1435 W MOREHEAD ST. SUITE 140CHARLOTTE, NC 28208D O N O T S C A L E D R A W I N G S , C O N T A C T A R C H I T E C T S W I T H Q U E S T I O N SARCHITECT:ATELIER MEY ARCHITECTS3642 WILLIAM AVEMIAMI FL 33133T: 612.414.7670LIC 29520 [SHAWNA MEYER]OWNER:MISSOURI HEIGHTSSTEFFANIE HARING, JUSTIN HARING4600 SOURDOUGH RDBOZEMAN, MT 59715417-288-1328CONTRACTOR:SITE PLAN SUBMISSION3/5/2025 3:01:22 PMA-0080SEPTEMBER 25, 2024HSSM | CMCOVER SHEET703 W MENDENHALL703 W MENDENHALL STBOZEMAN, MT 59715SHEET INDEXSHEET NUMBER SHEET NAMEA-0 COVER SHEETA-1 SITE PLANEA-1 EXISTING SITE PLANV-0 SITE SURVEYA-105 DESIGN OVERVIEW PLANA-114 CONSTRUCTION PLANC0.1 NOTES AND LEGENDC0.2 EX. AERIAL OVERVIEWC1.1 EXISTING CONDITIONSC1.2 DEMOLITION PLANC1.4 DESIGN PLANC2.1 STORM DRAIN SECTIONC2.2 STORMTANK DETAILC2.3 STORMTANK DETAILC2.4 STORMTANK DETAILC2.5 STORMTANK DETAILC5.1 DETAILSC5.2 DETAILSC5.3 DETAILSC5.4 DETAILSC5.5 DETAILSL101 OVERALL LANDSCAPEL102 NOTES AND SCHEDULEL201 LANDSCAPE DETAILSL202 LANDSCAPE DETAILSL301 OVERALL IRRIGATIONL302 IRRIGATION DETAILSA-2 BASEMENTA-3 GROUND FLOORA-4 SECOND FLOORA-5 THIRD FLOORA-6 FOURTH FLOORA-7 FIFTH FLOORA-8 ROOF PLANA-9 ELEVATIONSA-10 ELEVATIONSA-11 BLOCK FRONTAGEA-12 OPEN SPACE USEE210 EXTERIOR LIGHTING PLANE211 EXTERIOR LIGHTING ELEVATIONSOCCUPANCY TYPE S-2, R-2, BAVG. SITE GRADE ELEVATION 4821.5MIXED USEUNPROTECTED COMBUSTIBLECONSTRUCTION TYPEIII-B III-BBUILDING SQUARE FOOTAGE 21,375.82 SFMAXIMUM BUILDING HEIGHT 60 FT 5 STORIES OR 60'BUILDING CODE [B-2M]EXISTING ON STREET PARKING IS AVAILABLE FOR COMMERCIAL SPACE USE - 3 SPACESPROJECT PROVIDED 8 RESIDENTIAL PARKING SPACES + 1 RESIDENTIAL ACCESSIBLE SPACEMINIMUM PARKING REQUIREMENTS DO NOT APPLY - LOCATED IN MIDTOWN URBAN RENEWAL DISRICTPARKING REQUIREMENTS: PER BOZEMAN OF ORDINANCES 38.540.050ACCENTUATE THE STREET CORNERMUST LOCATE BUILDING WITHIN 10' OF STREET CORNER AND INCLUDE DESIGN FEATURES THATHIGH VISIBILITY STREET CORNER: PER BOZEMAN CODE OF ORDINANCE 38.530.05012'-0" MINIMUM BETWEEN CURB EDGE AND STOREFRONTSIDEWALK WIDTH:8-15' VERTICAL CLEARANCE AT LEAST 5' AVG. DEPTH ALONG AT LEAST 60% OF FACADEWEATHER PROTECTION:MIN. 40% OF GROUND FLOOR BETWEEN 30" AND 10' ABOVE THE SIDEWALK FOR SECONDARY FACADESMIN. 60% OF GROUND FLOOR BETWEEN 30" AND 10' ABOVE THE SIDEWALK FOR PRIMARY FACADESFACADE TRANSPARENCY: PRIMARY FACADE ON 7TH AVE / SECONDARY ON MENDENHALLBUILDING ENTRANCES MUST FACE THE STREET.BUILDING PLACEMENT REQUIRED AT FRONT PROPERTY LINE/BACK EDGE OF SIDEWALKMIXED [STOREFRONT] BLOCK FRONTAGE STANDARDS: PER BOZEMAN CODE OF ORDINANCES...NET RESIDENTIAL DENSITY 64NUMBER OF DWELLING UNITS 13NET RESIDENTIAL AREA 0.14 ACRESNET RESIDENTIAL DENSITYMINIMUM FLOOR TO FLOOR HEIGHT [NON-RESIDENTIAL] 16' 7" 15' MINBUILDING HEIGHT 60' 5 STORIES OR 60'BUILDING HEIGHTREAR - [EXISTING ALLEY] - WEST 12' - 8.5" 5' MIN [ALLEY]SIDE - NORTH 0' - 0" 5' MIN. OR 0 LOT LINESIDE - SECONDARY [W MENDENHALL] - SOUTH EDGE OF SIDEWALK EDGE OF 12' SIDEWALKFRONT - PRIMARY [N 7TH AVE] - EAST EDGE OF SIDEWALK EDGE OF 12' SIDEWALKSETBACK REQUIREMENTSSEE SHEET A-1 FOR OPEN SPACE DIAGRAMS[100 X 3] + [150 X 7] = 1,350 SF 1,650 SF 1,350 SF MIN.150 SF PER DWELLINGS WITH 2 OR MORE UNITS100 SF SF PER STUDIO AND 1 BEDROOM UNITSOPEN SPACE REQUIREMENTS PER BMC SEC. 38.520.060100% OF 5,968 IS 5,968 4,191 SF 5,968 MAXLOT COVERAGE [MAX LOT COVERAGE , 100%]5,968 SF MAXLOT WIDTH 50.0'LOT AREA 5,968 SF / 0.137 ACREBUILDING DISPOSITION PROVIDED ALLOWED / REQUIREDBLOCK FRONTAGE PER MBC SECTION 38.510 - MIXED. ADHERING TO STOREFRONT STANDARDSHIGH VISIBILITY STREET CORNER DESIGNATIONLOCATED IN THE MIDTOWN URBAN RENEWAL DISTRICTB-2M COMMUNITY BUSINESS DISTRICT MIXEDZONING DISTRICT - CITY OF BOZEMANZONING DATACROWN OF ROAD ELEVATION 48221ST FLOOR ELEVATION 4821.85BUILDING CODES - ALL WORK DONE ASPER: 2021 MONTANA BUILDING CODE, 2021MONTANA FIRE CODE, 2020 NATIONALELECTRICAL CODE, NFPA 101 LIFE SAFETYCODE LATEST EDITIONFLOOD LEGEND PROVIDEDREQUIRED /ALLOWEDRISK CATEGORY [TABLE 1604.5] IIEXPOSURE [TABLE 1609.4.3] COCCUPANCY LOAD MIXED-USEFIRE RESISTANCE HOURS PER TABLE 602 X>30 0 0FIRE RESISTANCE RATING [HOURS] PER TABLE 601 -BUILDING TYPE III-B0 TO 2 0 TO 2ALLOWABLE STORIES [TABLE 504.4] 5 5ALLOWABLE HEIGHT [TABLE 504.3] 60'-0" LESS THAN 75'-0"ALLOWABLE AREA [TABLE 506.2]21,375.82 SFTOTAL64,000 SFOCCUPANCY CLASSIFICATION PER IBC CHAPTER 3 SEC.310.5R-2, S-2, AND B R-2, S-2, AND BBUILDING CONSTRUCTION TYPE:III-B + SPRINKLERED + OCCUPANCY R-2, S-2, AND BPROVIDED ALLOWABLE / REQUIREDCODE ANALYSIS SUMMARYSCOPE OF WORK:THESE DRAWINGS ARE FOR A 21,375.82 SF MIXED USE NEW CONSTRUCTION BUILDING.ALL WORK DONE TO BE ACCORDING TO MONTANA BUILDING CODE 2021THE SCOPE OF THE WORK INCLUDES:01] SITE WORK02] STRUCTURAL03] MEP04] WINDOWS AND DOORS05] ROOFLANDSCAPE NOTES:SEE LANDSCAPE DRAWINGS FOR DETAILS AND SPECIFICATIONS. PERMIT NOTES:ALL PLANS AND CALCULATIONS HAVE BEEN PREPARED IN COMPLIANCE WITH MONTANA BUILDING CODE 2021.GENERAL NOTES:GENERAL CONTRACTOR AND SUBCONTRACTORS ARE RESPONSIBLE FOR VERIFYING CODE COMPLIANCE AND 'SYSTEM' FUNCTIONALITY BEFORE ANY WORK IS COVERED UP WITH FINAL SURFACES. IN THE EVENT A SYSTEM IS NONFUNCTIONAL OR ADJUSTMENTS TO COMPLETED WORK ARE REQUIRED TO MEET CODE COMPLIANCE, ARCHITECTS WILL NOT ACCEPT RESPONSIBILITY FOR CHANGES. GENERAL CONTRACTOR AND/OR ELECTRICAL SUBCONTRACTOR TO VERIFY CODE COMPLIANCE WITH SWITCHING AND OUTLET TYPE, PLACEMENT AND DISTRIBUTION BEFORE FINISH SURFACES ARE INSTALLED AND ELECTRICAL WORK IS COMPLETED OR COVERED UP. GENERAL CONTRACTOR AND/OR HVAC SUBCONTRACTOR TO VERIFY CODE COMPLIANCE, MAINTENANCE ACCESS AND FUNCTIONALITY BEFORE FINISH SURFACES ARE INSTALLED AND HVAC EQUIPMENT IS COMPLETED OR COVERED UP. LEGAL DESCRIPTION:THIS PROPERTY IS DESCRIBED AS:LOTS 11 & 12 IN BLOCK 8 OF SPRINBROOK ADDITION TO BOZEMAN LOCATED IN THE NORTHEAST ONE-QUARTER OF SECTION 12, TOWNSHIP 2 SOUTH, RANGE 5 EAST, PRINCIPAL MONTANA, CITY OF BOZEMAN, GALLATIN COUNTY, MONTANALOCATION SKETCH:[M] MAX DENSITY BY ZONE 12CASH-IN-LIEU [$] $2,30...TOTAL CILP/IILP $5,77...ZONING DISTRICT OTHER LAND APPRAISAL VALUE [$/SF] $2.65 ADDITIONAL IN-LIEU [$] $3,46...[D] NET RESIDENTIAL DENSITY 64 EQUIVALENT LAND AREA [AC] 0.02 CASH-IN-LIEU [$] $2,30...[du] NUMBER OF UNITS 13 ACRE/DU OF LAND 0.03 LAND DEDICATION [AC] 0.00[N] NET RESIDENTIAL LOT AREA [AC] 0.14 DWELLING/ACRE [DU] 4PARKLAND REQUIREDTOTAL EXCLUDED [AC] 0.00 NET RESIDENTIAL LAND AREA [AC] 0.14 IN-LIEU FEE EQUIVALENT [$] $3,46...[d] OPEN SPACE / PARK 0.00REQUIRED CASH-IN-LIEULAND APPRAISAL VALUE [$/SF] $2.65[a] ROW & EASEMENTS [AC] 0.00 LAND DEDICATION [AC] 0.03 LAND EQUIVALENT REQUIRED [AC] 0.03[s] SCHOOL OR PARK SITES [AC] 0.00 ACRE/DU OF LAND 0.03 LAND DEDICATION PROPOSED [AC] 0.00RESTRICTED LOTS [AC] 0.00 DWELLINGS/ACRE [DU] 8 LAND ALREADY PROVIDED [AC] 0.00[c] COMMERCIAL LOT AREA [AC] 0.00 NET RESIDENTIAL LAND AREA [AC] 0.14 PARKLAND DEDICATION REQUIRED [AC] 0.03TOTAL SITE AREA [AC] 0.14REQUIRED LAND DEDICATION ADJUSTMENTS TO PARKLAND REQUIREMENTSPARKLAND DEDICATIONACCESSIBILITY:THIS BUILDING HAS BEEN DESIGNED IN COMPLIANCE WITH THE STANDARDS OF THE AMERICANS WITH DISABILITIES ACT [ADA] AND THE FAIR HOUSING ACT [FHA] AS CERTIFIED BY THE ARCHITECT OF RECORD, ATELIER MEY ARCHITECTS.________________________________________ SHAWNA MEYER, AIA. DRIVEWAY CIRCULATION / PARKING AREAS [TOTAL SF] 38.22% 24.46%DRIVEWAY CIRCULATION / PARKING AREAS [TOTAL SF] 2281 SF 1461 SFBUILDINGS AND STRUCTURES [PERCENTAGE OF SITE] 22.62% 70.22%BUILDINGS AND STRUCTURES [TOTAL SF] 1350 SF 21,375.82 SFEXISTING PROPOSEDPARCEL AND SITE INFORMATIONRENDERED MATERIAL PERSPECTIVE | SOUTH EAST CORNER AT THE INTERSECTION OF WEST MENDENHALL STREET AND NORTH 7TH AVENUERENDERED MATERIAL PERSPECTIVE | WEST MENDENHALL STREET ELEVATIONRENDERED MATERIAL PERSPECTIVE | NORTH 7TH AVENUE ELEVATIONNo. Description Date1 Site Plan SubmissionRevision 0112/27/20242 Site Plan SubmissionRevision 203/07/2025