Loading...
HomeMy WebLinkAbout037 L-4.10 IRRIGATION DETAILSDATE ●ISSUE SHEET OF PROJECT NUMBER: SHEET TITLE  N R O U S E A 9 E  B O =E M A N  M T    Z Z Z I L H O G V W X G L R O D F R P EVERGOODSIRON HORSE ROAD2421.00 L-4.10 IRRIGATION DETAILS 5 7 2025.01.27 CITY SUBM. 2025.03.17 R1 CMTS. REDUCED PRESSURE BACKFLOW DEVICE 1" = 1'-0" SERVICE SIDE MAINLINE SIDE 1 2 3 4 5 6 7 REDUCED PRESSURE BACKFLOW DEVICE AS SPECIFIED1 UNIONS AT EACH SIDE2 RISERS3 CONCRETE THRUST BLOCKS, 90 LBS OF CONCRETE EACH4 NIPPLES AND ELL AS REQUIRED5 ELL AND NIPPLE, TYPICAL EACH SIDE6 COUPLER AND TOE NIPPLE, TYPICAL EACH SIDE7 1 FX-IR-FX-BACK-03 MASTER CONTROL VALVE 1 1/2" = 1'-0" FINISHED GRADE. SET BOX 2" ABOVE GRADE AT SHRUBS. SET BOX FLUSH TO GRADE AT TURF. A.E.P.RECTANGULAR BOX #1015 A.E.Q.WITH 6" EXTENSIONS AS REQUIRED. WATER PROOF WIRE CONNECTORS ON 30" LOOPED WIRES. 1/2" WIRE CLOTH GOPHER SCREEN, WRAP UP SIDES. PVC MAIN LINE.6X2X16 CONC. BLOCK CAPS, ONE EACH SIDE (2 TOTAL) SXT SCHEDULE 80 NIPPLES VALVE INLET SIZE. PVC CONDUIT FOR CONTROLLER WIRES. 18" M I N I M U M B E L O W G R A D E .12" MIN. BELOW GRADE.2 FX-IR-FX-MAST-06 NOTES: 1- LOCATE VALVE BOXES IN PLANTING AREAS. 2- WRAP VALVE BOX WITH A MINIMUM OF 3 MIL THICK PLASTIC AND SECURE IT USING DUCT TAPE OR ELECTRICAL TAPE. 3- ALL THREADED CONNECTION TO BE MADE USING TEFLON TAPE. 4- ALL CHANGES IN ELEVATION SHALL BE MADE USING SCH. 40 PVC 45° ELBOWS.6" MIN12" MAXBALL VALVE 3" AND SMALLER 1 1/2" = 1'-0" THREADED BALL VALVE. (SEE IRRIGATION LEGEND FOR MAKE AND MODEL). SCH. 80 PVC MALE ADAPTER. FINISHED GRADE. RECTANGULAR VALVE BOX WITH LOCKING LID. PAVEMENT. SCH. 80 PVC UNION SXS. SCH. 80 PVC NIPPLE TXS. MAINLINE. THREE INCH (3") THICK LAYER OF PEA GRAVEL OR APPROVED 38" WELDED WIRE MESH. SCH. 40 PVC 45° ELBOW. FOUR (4) 4" X 8" BRICKS. 3 FX-IR-FX-SHUT-01 "SIDE VIEW" "TOP VIEW" 1 SUPER JUMBO VALVE BOX1 2 FINISH GRADE2 3 DRIP ZONE KIT MODEL ICZ-151-40 WITH FILTER (TIP 45 DEGREES) REGULATOR 40 PSI 3 4 WATERPROOF CONNECTORS (2)4 5 18-24" COILED WIRE5 6 SCH 80 T.O.E. NIPPLE6 7 MAIN LINE PIPE & FITTINGS7 8 BRICK SUPPORTS (7)8 9 3/4" MINUS WASHED GRAVEL9 10 LATERAL PIPE AND FITTINGS10 1 6 3 6 7 6 ICZ-151-40 DRIP CONTROL KIT 1 1/2" = 1'-0"5 FX-IR-HUNT-DRIP-20 1 2 4 5 7 8 9 INTERIOR WALL MOUNT CONTROLLER W/ J-BOX 1" = 1'-0" 6 24" MIN.18" MIN. 3 SET CONTROLLER 60" ABOVE FINISHED GRADE UNLESS OTHERWISE SPECIFIED 1 CONTROLLER AS SPECIFIED. SECURELY BOLT CONTROLLER TO WALL. INSTALL BACKUP BATTERIES AS REQUIRED. GROUND AS PER MANUFACTURER SPECIFICATIONS 2 EXTERNAL WALL3 1/2" DIAMETER RIGID STEEL CONDUIT FOR 110 VAC ELECTRICAL SOURCE. INSTALL AS PER LOCAL ELECTRICAL CODES 4 2" DIAMETER GRAY PVC CONDUIT FOR RCV WIRES 5 LB JUNCTION BOX6 FINISHED FLOOR LEVEL7 LONG SWEEP ELL8 18' MIN. BEYOND STRUCTURE, OR TO BOX AS PER PLANS 9 4 FX-IR-FX-CONT-11 QUICK COUPLING VALVE IN BOX 1 1/2" = 1'-0" 10" DIAMETER VALVE BOX. HEAD BRAND "QVC" ON LID WITH 2" HIGH CHARACTERS. QUICK COUPLING VALVE AS SPECIFIED. GALV.NIPPLE, LENGTH AS REQ. 6" DEEP LAYER OF 3/4" CRUSHED ROCK. 12" PVC SCHEDULE 80 NIPPLE. 1/2" X 36" GALV STEEL PIPE. TWO STAINLESS STEEL CLAMPS. 3" PVC SCHEDULE 80 NIPPLE. THREE PVC SCH 80 ELLS. 12" MAX 6" MIN.1" MIN2" MAXFINISHED GRADE. FLUSH IN LAWN AREAS. 2" IN SHRUB AREAS. 6 FX-IR-FX-QUIC-03 WIRELESS RAIN/FREEZE-CLIK 3" = 1'-0" NOTE: MOUNT SENSOR ON ANY SURFACE WHERE IT WILL BE EXPOSED TO UNOBSTRUCTED RAINFALL, BUT NOT IN PATH OF SPRINKLER SPRAY, NO MORE THAN 1000' FROM RECEIVER UNIT. MOUNT UNIT NO FURTHER THAN 6' FROM CONTROLLER. WRC RECEIVER MODEL WRFC MOUNTING WALL 7 FX-IR-HUNT-SENS-18 DRIP EMITTER AT 1/4" TUBING 3" = 1'-0" DRIP EMITTER. 1/4" TUBING STAKE. 1/4" DISTRIBUTION TUBING, 48" MAXIMUM LENGTH. TOP OF MULCH ELEVATION. INSERT FITTING BARB CONNECTION OR INSERT BARBED TEE. 1/2" POLY DRIP TUBING. ADDITIONAL EMITTER AND STAKE AT INSERT BARBED TEE IN DRIP TUBING. TIE-DOWN STAKE AT INSERT. 8 FX-IR-FX-EMIT-03 DRIPLINE FLUSH VALVE AT GRADE 3" = 1'-0" COMPRESSION TEE AS OCCURS. DRIPLINE STAKING AS NOTED. DRIPLINE WITH EMITTERS AS NOTED. DRIPLINE STAKE AT COUPLER. DRIPLINE COMPRESSION COUPLER. FLUSH CAP AT GRADE. 10 FX-IR-FX-DRIP-07 13.2 GPH DRIPLINE RING NTS DRIPLINE TO LATERAL "XPANDO" ADAPTER CONNECTION DETAIL NOTE: PLACE TIE DOWN STAKES EVERY 3 FT. IN SAND, 4 FT. IN LOAM, AND 5 FT. IN CLAY, AS WELL AS AT ALL CHANGE OF DIRECTION SUCH AS AT TEES OR ELLS. 1 13 12 11 3 10 9 3 1 2 8 3 3 4 5 7 PVC LATERAL SUPPLY PIPE, SIZE AS PER PLAN1 DRIPLINE CONNECTION TO BELOW GRADE LATERAL PIPE, SEE DRIPLINE TO LATERAL "XPANDO" ADAPTER CONNECTION DETAIL. 2 POLYETHYLENE BLANK TUBING, AS REQUIRED. 3 BARB CROSS INSERT FITTING.4 BARB TEE INSERT FITTING.5 6 PLANT TRUNK.7 8 DRIPLINE BARBED INSERT ELL.9 RATCHET CLAMP AT ALL BARBED CONNECTIONS, ANTELCO PART NO. 44345. 10 INSERT ADAPTER, ANTELCO "XPANDO" 13MM X 14MM, PART NO. 45595. 11 13MM ANTELCO "CAPO: RUBBER GROMMET, NO. 45735. 12 DRILL HOLE IN PVC LATERAL PIPE WHERE REQUIRED. YOU MUST USE A "FORSTNER" DRILL BIT FOR DRILLING INTO PVC. REMOVE ANY EXCESS BURRS OR ROUGH EDGES. 13 8 TYPICAL ANTELCO ASTA TIE-DOWN STAKE, SEE NOTES. 6 AT-GRADE DRIPLINE, INNER RING 24" FROM PLANT, OUTTER RING 64" FROM PLANT. DRIPLINE TO BE 0.2GPH EMITTERS AT 12" O.C. 6 4 " 24"10" 9 FX-IR-FX-EMIT-01 REVIEW SET