HomeMy WebLinkAbout037 L-4.10 IRRIGATION DETAILSDATE ●ISSUE
SHEET OF
PROJECT NUMBER:
SHEET TITLE
N R O U S E A 9 E
B O =E M A N M T
Z Z Z I L H O G V W X G L R O D F R P
EVERGOODSIRON HORSE ROAD2421.00
L-4.10
IRRIGATION
DETAILS
5 7
2025.01.27 CITY SUBM.
2025.03.17 R1 CMTS.
REDUCED PRESSURE BACKFLOW DEVICE
1" = 1'-0"
SERVICE
SIDE
MAINLINE
SIDE
1
2
3
4
5
6
7
REDUCED PRESSURE BACKFLOW DEVICE AS SPECIFIED1
UNIONS AT EACH SIDE2
RISERS3
CONCRETE THRUST BLOCKS, 90 LBS OF CONCRETE EACH4
NIPPLES AND ELL AS REQUIRED5
ELL AND NIPPLE, TYPICAL EACH SIDE6
COUPLER AND TOE NIPPLE, TYPICAL EACH SIDE7
1 FX-IR-FX-BACK-03
MASTER CONTROL VALVE
1 1/2" = 1'-0"
FINISHED GRADE.
SET BOX 2" ABOVE GRADE AT SHRUBS.
SET BOX FLUSH TO GRADE AT TURF.
A.E.P.RECTANGULAR BOX #1015
A.E.Q.WITH 6" EXTENSIONS AS REQUIRED.
WATER PROOF WIRE CONNECTORS
ON 30" LOOPED WIRES.
1/2" WIRE CLOTH GOPHER
SCREEN, WRAP UP SIDES.
PVC MAIN LINE.6X2X16 CONC. BLOCK CAPS,
ONE EACH SIDE (2 TOTAL)
SXT SCHEDULE 80 NIPPLES VALVE INLET SIZE.
PVC CONDUIT FOR
CONTROLLER WIRES.
18" M
I
N
I
M
U
M
B
E
L
O
W
G
R
A
D
E
.12" MIN. BELOW GRADE.2 FX-IR-FX-MAST-06
NOTES:
1- LOCATE VALVE BOXES IN PLANTING AREAS.
2- WRAP VALVE BOX WITH A MINIMUM OF 3 MIL THICK PLASTIC AND SECURE IT USING DUCT TAPE OR ELECTRICAL TAPE.
3- ALL THREADED CONNECTION TO BE MADE USING TEFLON TAPE.
4- ALL CHANGES IN ELEVATION SHALL BE MADE USING SCH. 40 PVC 45° ELBOWS.6" MIN12" MAXBALL VALVE 3" AND SMALLER
1 1/2" = 1'-0"
THREADED BALL VALVE. (SEE
IRRIGATION LEGEND FOR MAKE
AND MODEL).
SCH. 80 PVC MALE ADAPTER.
FINISHED GRADE.
RECTANGULAR VALVE BOX WITH
LOCKING LID.
PAVEMENT.
SCH. 80 PVC UNION SXS.
SCH. 80 PVC NIPPLE TXS.
MAINLINE.
THREE INCH (3") THICK LAYER
OF PEA GRAVEL OR APPROVED
38" WELDED WIRE MESH.
SCH. 40 PVC 45° ELBOW.
FOUR (4) 4" X 8" BRICKS.
3 FX-IR-FX-SHUT-01
"SIDE VIEW"
"TOP VIEW"
1
SUPER JUMBO VALVE BOX1
2
FINISH GRADE2
3
DRIP ZONE KIT
MODEL ICZ-151-40 WITH FILTER (TIP
45 DEGREES) REGULATOR 40 PSI
3
4
WATERPROOF CONNECTORS (2)4
5
18-24" COILED WIRE5
6
SCH 80 T.O.E. NIPPLE6
7
MAIN LINE PIPE & FITTINGS7
8
BRICK SUPPORTS (7)8
9
3/4" MINUS WASHED GRAVEL9
10
LATERAL PIPE AND FITTINGS10
1
6
3
6
7
6
ICZ-151-40 DRIP CONTROL KIT
1 1/2" = 1'-0"5 FX-IR-HUNT-DRIP-20
1
2
4
5
7
8
9
INTERIOR WALL MOUNT CONTROLLER W/ J-BOX
1" = 1'-0"
6
24" MIN.18" MIN.
3
SET CONTROLLER 60" ABOVE
FINISHED GRADE UNLESS
OTHERWISE SPECIFIED
1
CONTROLLER AS SPECIFIED.
SECURELY BOLT
CONTROLLER TO WALL.
INSTALL BACKUP BATTERIES
AS REQUIRED. GROUND AS
PER MANUFACTURER
SPECIFICATIONS
2
EXTERNAL WALL3
1/2" DIAMETER RIGID STEEL
CONDUIT FOR 110 VAC
ELECTRICAL SOURCE.
INSTALL AS PER LOCAL
ELECTRICAL CODES
4
2" DIAMETER GRAY PVC
CONDUIT FOR RCV WIRES
5
LB JUNCTION BOX6
FINISHED FLOOR LEVEL7
LONG SWEEP ELL8
18' MIN. BEYOND STRUCTURE,
OR TO BOX AS PER PLANS
9
4 FX-IR-FX-CONT-11
QUICK COUPLING VALVE IN BOX
1 1/2" = 1'-0"
10" DIAMETER VALVE BOX.
HEAD BRAND "QVC" ON LID WITH
2" HIGH CHARACTERS.
QUICK COUPLING VALVE AS SPECIFIED.
GALV.NIPPLE, LENGTH AS REQ.
6" DEEP LAYER OF 3/4" CRUSHED ROCK.
12" PVC SCHEDULE 80 NIPPLE.
1/2" X 36"
GALV STEEL PIPE.
TWO STAINLESS
STEEL CLAMPS.
3" PVC SCHEDULE 80 NIPPLE.
THREE PVC SCH 80 ELLS.
12" MAX
6" MIN.1" MIN2" MAXFINISHED GRADE.
FLUSH IN LAWN AREAS.
2" IN SHRUB AREAS.
6 FX-IR-FX-QUIC-03
WIRELESS RAIN/FREEZE-CLIK
3" = 1'-0"
NOTE:
MOUNT SENSOR ON ANY SURFACE WHERE IT WILL BE EXPOSED
TO UNOBSTRUCTED RAINFALL, BUT NOT IN PATH OF SPRINKLER SPRAY, NO
MORE THAN 1000' FROM RECEIVER UNIT. MOUNT UNIT NO FURTHER THAN 6'
FROM CONTROLLER.
WRC RECEIVER
MODEL WRFC
MOUNTING WALL
7 FX-IR-HUNT-SENS-18
DRIP EMITTER AT 1/4" TUBING
3" = 1'-0"
DRIP EMITTER.
1/4" TUBING STAKE.
1/4" DISTRIBUTION TUBING, 48" MAXIMUM LENGTH.
TOP OF MULCH ELEVATION.
INSERT FITTING BARB CONNECTION
OR INSERT BARBED TEE.
1/2" POLY DRIP TUBING.
ADDITIONAL EMITTER AND STAKE AT
INSERT BARBED TEE IN DRIP TUBING.
TIE-DOWN STAKE AT
INSERT.
8 FX-IR-FX-EMIT-03
DRIPLINE FLUSH VALVE AT GRADE
3" = 1'-0"
COMPRESSION TEE AS OCCURS.
DRIPLINE STAKING AS NOTED.
DRIPLINE WITH EMITTERS AS NOTED.
DRIPLINE STAKE AT COUPLER.
DRIPLINE COMPRESSION COUPLER.
FLUSH CAP AT GRADE.
10 FX-IR-FX-DRIP-07
13.2 GPH DRIPLINE RING
NTS
DRIPLINE TO LATERAL "XPANDO"
ADAPTER CONNECTION DETAIL
NOTE:
PLACE TIE DOWN STAKES EVERY 3 FT. IN SAND, 4 FT.
IN LOAM, AND 5 FT. IN CLAY, AS WELL AS AT ALL
CHANGE OF DIRECTION SUCH AS AT TEES OR ELLS.
1
13
12
11
3
10
9
3
1 2
8 3
3
4
5
7
PVC LATERAL SUPPLY PIPE, SIZE AS PER PLAN1
DRIPLINE CONNECTION TO BELOW GRADE
LATERAL PIPE, SEE DRIPLINE TO LATERAL
"XPANDO" ADAPTER CONNECTION DETAIL.
2
POLYETHYLENE BLANK TUBING, AS
REQUIRED.
3
BARB CROSS INSERT FITTING.4
BARB TEE INSERT FITTING.5
6
PLANT TRUNK.7
8
DRIPLINE BARBED INSERT ELL.9
RATCHET CLAMP AT ALL BARBED CONNECTIONS,
ANTELCO PART NO. 44345.
10
INSERT ADAPTER, ANTELCO "XPANDO" 13MM X
14MM, PART NO. 45595.
11
13MM ANTELCO "CAPO: RUBBER GROMMET, NO.
45735.
12
DRILL HOLE IN PVC LATERAL PIPE
WHERE REQUIRED. YOU MUST USE A
"FORSTNER" DRILL BIT FOR DRILLING INTO PVC.
REMOVE ANY EXCESS BURRS OR ROUGH
EDGES.
13
8
TYPICAL ANTELCO ASTA TIE-DOWN STAKE, SEE
NOTES.
6
AT-GRADE DRIPLINE, INNER RING 24" FROM
PLANT, OUTTER RING 64" FROM PLANT.
DRIPLINE TO BE 0.2GPH EMITTERS AT 12" O.C.
6
4
"
24"10"
9 FX-IR-FX-EMIT-01
REVIEW SET