027 E0.3 PHOTOMETRIC SITE PLAN
NEW BUILDINGDL3 DL3 DL3EDL3EWP2EWP2EWP1EDL3DL3Z1Z2Z3Z4WP2WP2DL3DL3DL3 DL3CTMETERWP2DL3DL311A. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS, CONDUITS, DIFFUSERS, BOXES, AND OTHER ITEMS THROUGHOUT THIS PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.B. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING OF FLOORS, WALLS, CEILINGS, AND ROOFS TO PERFORM THE REQUIRED WORK DEPICTED IN THESE DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PATCHING OF HOLES TO THE SATISFACTION OF THE ARCHITECT/ENGINEER.C. CONTRACTOR IS FULLY RESPONSIBLE FOR FOLLOWING ALL APPLICABLE CODES AND STANDARDS, AS WELL AS ALL LOCAL ADDENDUM TO THOSE CODES AND STANDARDS, WHETHER SPECIFICALLY SHOWN ON THESE DRAWINGS OR NOT.D. WIRELESS ACCESS POINT LAYOUT AS SHOWN IN DESIGN APPROXIMATION FOR ROUGH-IN COST ESTIMATION PURPOSES ONLY. COORDINATE EXACT LOCATION AND QUANTITY OF WIRELESS ACCESS POINTS WITH TELECOMMUNICATION SYSTEM DESIGN BY OTHERS PRIOR TO ROUGH-IN.E. ON SLOPED CEILINGS, DO NOT LOCATE SMOKE DETECTORS WITHIN 4" OF THE HIGHEST EDGE OF A CEILING AS MEASURED HORIZONTALLY.GENERAL ELECTRICAL NOTES:PROJECT #SHEET NUMBERREVISION:DATE618 N Wallace | Bozeman, MT 59715DRAFTNOT FOR CONSTRUCTIONThis drawing is not intended nor shall it be used for construction purposes unless the signed professional stamp of a regisered architect employed at MINARIK Architecture, Inc. is affixed above.Consultant:971-319-6249 | www.minarikarch.comProject Status:© 2024 MINARIK Architecture, IncALL RIGHTS RESERVEDThese Drawings are the Property of MINARIK Architecture, Inc and are not to be used or reproduced in any manner without prior written permission.3/14/2025 3:58:49 PM12404E0.3Evergoods.2214,2218,2200 IRON HORSE RDBozeman, MT 5971501/27/2025PHOTOMETRIC SITEPLANSITE PERMIT SETE0.3SCALE: 3/32" = 1'-0"ELEC - PHOTOMETRIC SITE PLAN1NKEYED NOTESREVISION DATE REASON FOR ISSUE103/14/2025 Site Plan Review #1SITE PLAN PHOTOMETRICSCalculation Points Name Average Maximum Minimum Avg/MinMax/MinPLAN SOUTH PROPERTY LINE 0 fc 0.4 fc 0.1 fc 1.8 2.5PLAN EAST PROPERTY LINE 0 fc 0.4 fc 0.0 fc 10.9 31.0PLAN SOUTH WEST PROPERTY LINE 0 fc 0.5 fc 0.0 fc 240.3 500.3PLAN NORTH WEST PROPERTY LINE 0 fc 0.1 fc 0.0 fc 0.0 0.0SIDWALK PATH EAST 1 fc 2.8 fc 0.1 fc 10.8 25.1BACK ENTRANCE 4 fc 4.8 fc 2.2 fc 1.8 2.2PLAN EAST PARKING LOT 1 fc 2.7 fc 0.2 fc 5.0 13.0PLAN WEST PARKING LOT 1 fc 1.9 fc 0.2 fc 4.5 9.5LOADING DOCK 2 fc 3.2 fc 1.2 fc 1.8 2.6SIDE ENTRANCE 2 fc 3.4 fc 1.0 fc 2.3 3.5SIDWALK PATH WEST 1 fc 6.2 fc 0.2 fc 5.1 36.8MAIN ENTRANCE 4 fc 5.8 fc 0.4 fc 10.2 15.8103/14/2025