025 E0.0 ELEC COVER SHEET
MMMSPDLAPFCMVFDCBPNL A208Y/120V3ø, 4WXXX-XXXXS PS FS THSDSSSCDFFFSSWACRREDCESELMDGBCHSDXXJTVJPS-XXD-1XELECTRICAL GENERAL NOTESA. PRIOR TO BID CONTRACTOR SHALL VISIT THE SITE. NOT ALL WORK REQUIRED TO COMPLETE THE PROJECT IS SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL BECOME THOROUGHLY FAMILIAR WITH ALL THE WORK REQUIRED TO COMPLETE THE PROJECT IN ADDITION TO THE LOCAL CONDITIONS AND INCLUDE SAID WORK IN THE BID.B. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL ELECTRICAL SERVICE WORK WITH UTILITY. OWNER PAYS ALL FEES, CONTRACTOR DOES ALL SCHEDULING AND COORDINATION OF WORK. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE ALL SCHEDULES ARE MET.C. GENERAL WORK PRACTICES FOR ELECTRICAL CONSTRUCTION SHALL BE IN ACCORDANCE WITH NECA 1, "STANDARD PRACTICES FOR GOOD WORKMANSHIP IN ELECTRICAL CONTRACTING." THIS PUBLICATION IS AVAILABLE FROM NECA BY TELEPHONE AT 301-657-3110 OR ON-LINE AT WWW.NECANET.ORG.D. DURING DEMOLITION, THE CONTRACTOR SHALL NOTE ALL EXISTING RACEWAY (BOTH SURFACE AND CONCEALED) TO THE EXTENT POSSIBLE. THESE RACEWAYS SHALL BE REUSED TO THE GREATEST EXTENT POSSIBLE TO INSURE A CLEAN FINISHED PRODUCT. WHERE PRACTICAL, AND ALLOWED PER CODE, FISHING THROUGH WALLS WITH MC CABLE IS PREFERRED TO SURFACE-MOUNTED CONDUIT.E. CONTRACTOR SHALL REMOVE, TRANSPORT, AND LEGALLY DISPOSE OF LAMPS AND BALLASTS OFF-SITE. IT IS ASSUMED THE THE BALLASTS DO NOT CONTAIN PCBs. THE CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY IF IT IS SUSPECTED THAT BALLASTS CONTAIN PCBs. F. ALL POWER INTERRUPTIONS SHALL BE COORDINATED WITH OWNER. ANY DISRUPTION OF WORKERS IN THE SPACE SHALL BE KEPT TO A MINIMUM AND BE COORDINATED WITH THE OWNER PRIOR TO WORK COMMENCING IN THAT SPACE. G. CONTRACTOR SHALL EXTEND UNSWITCHED HOT LEG FROM EXISTING EMERGENCY FIXTURE LOCATION TO NEW EMERGENCY FIXTURES. AS NEEDED. SEE DEMO PLANS FOR AN APPROXIMATION OF EXISTING EMERGENCY FIXTURE LOCATIONS. FIELD VERIFY EXACT LOCATION PRIOR TO BID.H. IT IS THE CONTRACTORS RESPONSIBILITY TO COORDINATE WITH MECHANICAL FOR PLENUM SPACES AND PROVIDE PLENUM RATED CABLES WHERE REQUIRED FOR LIGHTING CONTROL, DATA, FIRE ALARM AND ALL OTHER L.V. SYSTEMS NOT INSTALLED IN CONDUIT. VERIFY CONDUIT REQUIREMENTS ON DRAWINGS AND SPECIFICATIONS.I. FIRE-RESISTANCE: PROVIDE A MINIMUM HORIZONTAL DISTANCE OF 24" BETWEEN OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE-RESISTANCE RATED WALLS. WHERE THIS IS NOT POSSIBLE INSTALL UL LISTED PUTTY PADS ON ALL OUTLET BOXES NOT MEETING THE 24" SEPARATION. PROVIDE A UL LISTED THROUGH -PENETRATION FIRESTOP FOR PENETRATIONS OF FIRE-RESISTANCE RATED ASSEMBLIES.J. CONDUCTORS ARE SIZED PER THE 75 DEGREE C RATING COLUMN OF NEC TABLE 310.16. IF THE TERMINAL USED FOR A TERMINATION OF A PARTICULAR CONDUCTOR IS NOT MARKED, OR THE TERMINAL IS MARKED FOR 60 DEGREE C CONDUCTORS, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EITHER ADJUST THE AMPACITY OF THE CONDUCTOR TO MATCH THE 60 DEGREE COLUMN OF TABLE 310.16, OR REPLACE THE TERMINAL WITH ONE RATED FOR AT LEAST 75 DEGREES C.K. BASED ON ACTUAL HOMERUN LENGTHS REQUIRED IN THE FIELD, THE CONTRACTOR SHALL CALCULATE AND INCREASE THE WIRE SIZES AS REQUIRED TO LIMIT BRANCH CIRCUIT VOLTAGE DROP TO 3%. FOR 20A BRANCH CIRCUITS THE MINIMUM CONDUCTOR SIZES SHALL BE AS FOLLOWS: #10 AMG CU FOR RUNS BETWEEN 100 AND 200 LINEAR FEET, #8 AWG CU FOR RUNS BETWEEN 200 AND 325 LINEAR FEET, ANS AS CALCULATED BY THE CONTRACTOR FOR CIRCUITS EXTENDING BEYOND 325 LINEAR FEET. IN ALL CASES WHERE WIRE SIZES INCREASE, THE CONTRACTOR SHALL PROVIDE LARGER CONDUITS AS REQUIRED.L. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH 120V BRANCH CIRCUIT.M. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS, CONDUITS, DIFFUSERS, BOXES, AND OTHER ITEMS THROUGHOUT THIS PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.N. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING OF FLOORS, WALLS, CEILINGS, AND ROOFS TO PERFORM THE REQUIRED WORK DEPICTED IN THESE DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PATCHING OF HOLES TO THE SATISFACTION OF THE ARCHITECT/ENGINEER.O. ELECTRICAL CONTRACTOR SHALL ADHERE TO THE LATEST ADOPTED VERSION OF ALL APPLICABLE CODES AND ANY LOCAL ADDENDUM TO THOSE CODES.ELECTRICAL ABBREVIATIONS LEGENDA, AMP AMPERESAC ALTERNATING CURRENTA/C AIR CONDITIONINGAF AMP FUSEAFF ABOVE FINISHED FLOORAFG ABOVE FINISHED GRADEAHU AIR HANDLING UNITAL ALUMINUMAS AMP SWITCHATS AUTOMATIC TRANSFER SWITCHBAS BUILDING AUTOMATION SYSTEMBKR BREAKERC RACEWAY/CONDUITCB CIRCUIT BREAKERCCTV CLOSED CIRCUIT TELEVISIONCKT CIRCUITCLG CEILINGC.O. RACEWAY/CONDUIT ONLY, WITH PULL STRINGCNTRL CONTROLCU COPPERD EXISTING TO BE DEMOLISHEDDISC DISCONNECTDIST DISTRIBUTIONDPDT DOUBLE POLE DOUBLE THROWDWG DRAWINGEA EACHEF EXHAUST FANELEC ELECTRICEMT ELECTRICAL METALLIC TUBINGEQUIP EQUIPMENTEX, EXIST EXISTINGFA FIRE ALARMFAA FIRE ALARM ANNUNCIATORFACP FIRE ALARM CONTROL PANELFD FUSED DISCONNECTFLR FLOORFO FIBER OPTICFSD FIRE SMOKE DAMPER RELAY, CONTROLLED BY ASSOCIATED SMOKE DETECTOR AND CIRCUITED BACK TO FACPFVNR FULL VOLTAGE NON-REVERSINGFVR FULL VOLTAGE REVERSINGGEC GROUNDED ELECTRODE CONDUCTORGFCI GROUND FAULT CIRCUIT INTERRUPERGFI GROUND FAULT INTERRUPTERGFP GROUND FAULT PROTECTIONGND GROUNDGRC GALVANIZED RIGID CONDUITHID HIGH INTENSITY DISCHARGEHOA HAND-OFF-AUTOMATICHP HORSEPOWERHPS HIGH PRESSURE SODIUMHTR HEATERHVAC HEATING, VENTILATION & AIR CONDITIONINGHZ HERTZJ-BOX JUNCTION BOXKVA KILOVOLT-AMPERESKW KILOWATTSLCP LIGHTING CONTROL PANELLPW LUMENS PER WATTLTG LIGHTINGLV LOW VOLTAGEMAG MAGNETIC STARTERMAN MANUALMAX MAXIMUMMCA MINIMUM CIRCUIT AMPACITYMCC MOTOR CONTROL CENTERMDP MAIN DISTRIBUTION PANELMECH MECHANICALMH METAL HALIDEMIN MINIMUMMSS MOTOR STARTER SWITCH WITH THERMAL OVERLOADSN NEUTRALNC NORMALLY CLOSEDNEC NATIONAL ELECTRIC CODENEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATIONNFD NON-FUSED DISCONNECTNIC NOT IN CONTRACTNO NORMALLY OPEN# NUMBEROAE OR APPROVED EQUALOC ON CENTEROCPD OVERCURRENT PROTECTIVE DEVICEOH OVERHEADP POLEPB PUSHBUTTONPH PHASEPNL PANELPVC POLYVINYL CHLORIDE CONDUITPWR POWERR EXISTING TO REMAINRCPT RECEPTACLERECEPT RECEPTACLERGS RIGID GALVANIZED STEELRM ROOMRVNR REDUCED VOLTAGE NON-REVERSINGRVR REDUCED VOLTAGE REVERSINGSP SINGLE POLE TOGGLE SWITCHSPD SURGE PROTECTIVE DEVICE (TVSS)SPEC SPECIFICATIONSPST SINGLE POLE SINGLE THROWSSPB START-STOP PUSHBUTTONSW SWITCHSWBD SWITCHBOARDSWGR SWITCHGEARTB TELEPHONE BOARDTC TIME CLOCKTD TIME DELAYTEL TELEPHONETSP TWISTED SHIELDED PAIRTTB TELEPHONE TERMINAL BOARDTYP TYPICALUG UNDERGROUNDUH UNIT HEATERUNO UNLESS NOTED OTHERWISEV VOLTVA VOLT-AMPERESVFD VARIABLE FREQUENCY DRIVEW WATTSWP WEATHERPROOFW/O WITHOUTXFMR TRANSFORMERY WYE-CONNECTED∆ DELTA-CONNECTEDø PHASEABBREVIATIONS AND SYMBOLS GENERAL NOTESA. THE ABBREVIATIONS ON THIS SHEET COMPRISE A STANDARD LIST; NOT ALL ABBREVIATIONS APPEAR ON THIS PROJECT.B. THE SYMBOLS ON THIS SHEET COMPRISE A STANDARD LIST; NOT ALL SYMBOLS APPEAR ON THIS PROJECT.C. ALL MOUNTING HEIGHTS ARE TO CENTER OF DEVICE ABOVE FINISHED FLOOR, UNLESS NOTED OTHERWISE. MOUNTING HEIGHTS INDICATED ON ARCHITECTURAL WALL ELEVATIONS OR AS NOTED SPECIFICALLY ON THE DRAWINGS OR IN THE SPECIFICATIONS SHALL TAKE PRECEDENCE OVER MOUNTING HEIGHTS LISTED.ELECTRICAL ONE-LINE LEGENDMOTOR SYMBOLCT AND CUSTOMER POWER METERUTILITY ELECTRIC METER AND BASE (BASE BY CUSTOMER)SURGE PROTECTION DEVICELIGHTNING ARRESTORSTRESS RELIEF CONEPOWER FACTOR CORRECTION CAPACITORMOTOR STARTER SWITCH W/ THERMAL OVERLOADSCONTACTOR NORMALLY OPEN, NORMALLY CLOSEDTRANSFORMER, 3-PH, 3-WIRE DELTA CONNECTIONTRANSFORMER, 3-PH, 4-WIRE GROUNDED WYE CONNECTIONAUTOMATIC TRANSFER SWITCHVARIABLE FREQUENCY DRIVEFIXED MOUNT LV BREAKERLSIG -LONG-TIME + SHORT-TIME + INSTANTANEOUS + EQUIPMENT GROUND-FAULT PROTECTION MICROLOGIC CIRCUIT BREAKERLSI -LONG-TIME + SHORT-TIME + INSTANTANEOUS + MICROLOGIC CIRCUIT BREAKERFUSED SWITCH ("XXAS/XXAF" -SW AND FUSE AMP RATING)WALL MOUNTED BREAKERTHERMAL OVERLOAD ELEMENTDISCONNECT SWITCH ("XXAS" = SWITCH AMP RATING)FUSED DISCONNECT SWITCH ("XXAS/XXAF" = SW AND FUSE AMP RATING)COMBINATION MOTOR STARTER (STR SIZE, TYP, AS, AF, SEE MEP COORDINATION SCHEDULE)SWITCHBOARD OR PANELBOARD; NAME, VOLTAGE, PHASE, NUMBER OF WIRES WHEN INDICATED ELECTRICAL LIGHTING FIXTURE LEGENDRECESSED PANEL LIGHT-NORMAL POWER-BACKUP POWER VIA INTEGRAL BATTERYEXIT SIGN -WALL MOUNT, CEILING MOUNT, BUG EYE. ARROW INDICATES DIRECTION OF TRAVEL, SHADING INDICATES LIGHTED FACE. PROVIDE WITH INTEGRAL BATTERYSURFACE PANEL LIGHT-NORMAL POWER-BACKUP POWER VIA INTEGRAL BATTERYSURFACE WALL MOUNT LED FIXTURE-NORMAL POWER-BACKUP POWER VIA INTEGRAL BATTERYLINEAR LIGHT -SURFACE OR SUSPENDED-NORMAL POWER-BACKUP POWER VIA INTEGRAL BATTERYPENDANT FIXTURE; HIGH BAY, LOW BAY, DECORATIVEDUAL HEAD EMERGENCY EGRESS BATTERY PACK, WALL MOUNT OR CEILING MOUNTWALL MOUNTED SCONCESURFACE DOWNLIGHTSURFACE EMERGENCY DOWNLIGHT WITH INTEGRAL BATTERYRECESSED CAN DOWNLIGHTRECESSED CAN EMERGENCY DOWNLIGHT WITH INTEGRAL BATTERYRECESSED CAN WALL WASHERSLOPED RECESSED DOWNLIGHTELECTRICAL LIGHTING CONTROL LEGENDOCCUPANCY SENSOR -WALL MOUNT, CEILING MOUNT. WATTSTOPPER DT-300 DUAL TECHNOLOGY, OR EQUAL, WITH BZ-50 POWER PACKS AS NEEDED.VACANCY SENSOR -WALL MOUNT, CEILING MOUNT. WATTSTOPPER DT-300 DUAL TECHNOLOGY, OR EQUAL, WITH BZ-50 POWER PACKS AS NEEDED.TOGGLE SWITCH (MOUNT AT +46", UNO)"X" INDICATES TYPE:BLANK -SINGLE POLE3 -INDICATES THREE-WAY4 -INDICATES FOUR-WAYM -INDICATES MASTER SWITCHK -INDICATES KEYED SWITCHT -INDICATES TIMERP -INDICATES PILOT LIGHTOS -INDICATES WALL SWITCH OCC SENSORWATTSTOPPER DW100 (SINGLE OR DUAL DW-200 SWITCH)OSD -INDICATES WALL SWITCH OCC SENSOR WITH 0-10V DIMMING -WATTSTOPPER W-311"Y" INDICATES ROOM AND ZONE:1a -INDICATES SINGLE POLE LIGHTING SWITCH ZONE FOR ZONE a IN ROOM 11b -INDICATES SINGLE POLE LIGHTING SIWTCH ZONE FOR ZONE b IN ROOM 11 -INDICATES LIGHTING SWITCHES WITH MULTIPLE ZONES IN ROOM 1OCCUPANCY SENSOR -CEILING MOUNT, WALL MOUNTWATTSTOPPER LMDC-100, OR EQUALPHOTOCELL -CEILING MOUNTWATTSTOPPER LMLS-400, OR EQUALPHOTOCELL -CEILING MOUNT, WATTSTOPPER LS-301, OR EQUALSTANDARD LIGHTING CONTROLS:SWITCHES AND LINE VOLTAGE DIMMERSDIGITAL LIGHTING CONTROLS:ROOM CONTROLLERS AND LOW VOLTAGE DEVICESON/OFF ROOM CONTROLLER WITH (1) RELAY. WATTSTOPPER DLM LMRC-101, OR EQUALON/OFF/0-10V DIMMER ROOM CONTROLLER WITH (1) RELAYS WATTSTOPPER DLM LMRC-211, OR EQUALON/OFF/0-10V DIMMER ROOM CONTROLLER WITH (2) RELAYS WATTSTOPPER DLM LMRC-212, OR EQUALLOW VOLTAGE ON/OFF SWITCH WATTSTOPPER DLM LVSW-101-W, OR EQUALR1R1R2ON/OFF/0-10V DIMMER ROOM CONTROLLER WITH (3) RELAYS WATTSTOPPER DLM LMRC-213, OR EQUALR3OSOSPLVOSLVOSLVPSXYSDDIMMER SWITCH (MOUNT AT +46", UNO)"X" INDICATES TYPE:OS -OCCUPANCY SENSORVS -VACANCY SENSOR(X) -INDICATED LIGHTING FIXTURE BEING CONTROLLED BY SWITCHXVSON/OFF/0-10V DIMMER ROOM CONTROLLER WITH (1) RELAYS, UL924 EMERGENCY ROOM, WATTSTOPPER DLM LMRC-211, OR EQUALER1ON/OFF/0-10V DIMMER ROOM CONTROLLER WITH (2) RELAYS, UL 924 EMERGENCY ROOM, WATTSTOPPER DLM LMRC-212, OR EQUALER2ON/OFF/0-10V DIMMER ROOM CONTROLLER WITH (3) RELAYS, UL924 EMERGENCY ROOM, WATTSTOPPER DLM LMRC-213, OR EQUALER3ON/OFF ROOM CONTROLLER WITH (1) RELAY. WATTSTOPPER DLM LMRC-102, OR EQUALR2DLOW VOLTAGE 0-10V DIMMING SWITCH WATTSTOPPER DLM LMDM-101, OR EQUALELECTRICAL LOW VOLTAGE LEGENDFIRE ALARM SYSTEMTELEPHONE/DATA SYSTEMSPRINKLER PRESSURE SWITCHSPRINKLER FLOW SWITCHSPRINKLER TAMPER SWITCHHEAT DETECTORSMOKE DETECTOR -PHOTO-ELECTRICSMOKE DETECTOR"X" INDICATES TYPE:D -DUCT SMOKE DETECTORE -ELEVATOR SMOKE DETECTOR, A DEVICE THAT TRIGGERS ELEVATOR RECALL FOLLOWED BY SHUNT TRIP OF BREAKERS SERVING THE ELEVATOR AND ELEVATOR SHAFT PER NFPA 72 17.7.3.11, 17.7.3.1.3, 21.3.5.1 AND 21.3.5.2SINGLE-STATION SMOKE DETECTOR. PROVIDE 120V AND MONITOR AT FACP VIA RELAY.COMBINATION SMOKE AND CARBON MONOXIDE DETECTORDOOR HOLDERTWO WAY EMERGENCY CALL STATION. (MOUNT AT +46", UNO)STROBE -WALL MOUNT (+90"), CEILING MOUNTHORN/STROBE -WALL MOUNT (+90"), CEILING MOUNT, LOW FREQUENCY, CEILING MOUNTSPEAKER STROBE -WALL MOUNT (+90"), CEILING MOUNTTELEPHONE OUTLET (MOUNT AT +18", UNO).SEE NOTE.VOICE-DATA OUTLET (MOUNT AT +18", UNO).SEE NOTE.DATA OUTLET (MOUNT AT +18", UNO). SEE NOTE.WIRELESS ACCESS POINTCABLE TRAY OR BASKET TRAY -LENGTH AND HEIGHT PER PLANSECURITY SYSTEMCARD READER -SEE ELECTRICAL DETAILS FOR ROUGH-IN (MOUNT AT +46", OR MATCH ADJACENT DOOR ACCESS CONTROL)REQUEST TO EXIT MOTION DETECTORDOOR CONTACTSELECTRIC STRIKEELECTRIC LOCKMOTION DETECTORGLASS BREAK DETECTORCCTV CAMERA -CEILING MOUNT OR WALL MOUNT. SEE NOTE.NOTE:PROVIDE ROUGH-IN ONLY. SINGLE GANG BOX WITH MUD RING & 1" C. STUBBED UP TO ACCESSIBLE CEILING SPACE.NOTE:PROVIDE ROUGH-IN ONLY. 2-GANG BOX WITH MUD RING & 1" C. STUBBED UP TO ACCESSIBLE CEILING SPACE.HEAT DETECTOR"X" INDICATES TYPE:RC -COMBINATION RATE-OF-RISE HEAT AND CO DETECTORL -RATE-OF-RISE HEAT DETECTOR WITH 50' SPACING CRITERIAS -RATE-OF-RISE HEAT DETECTOR WITH 50' SPACING CRITERIAE -ACTIVATES SHUNT TRIP WITHOUT DELAYXxE MANUAL PULL STATION (MOUNT AT +46", UNO)TTACTILE ALARM DEVICE (MOUNT AT +48" AFF, UNO)ELECTRICAL POWER LEGENDPANEL AND CIRCUIT DESIGNATION ARE SHOWN NEXT TO EACH DEVICE (PANEL NAME -CIRCUIT NUMBER). A SINGLE INSULATED GREEN GROUND CONDUCTOR SHALL BE PROVIDED WITH EACH HOME RUN. PROVIDE A SEPARATE NEUTRAL FOR EACH CIRCUIT. HOME RUNS SHALL HAVE NO MORE THAN THREE CIRCUITS. LINE VOLTAGE AND LOW VOLTAGE WIRING IS NOT SHOWN ON PLANS."X" INDICATES TYPE:GFI -GROUND FAULT INTERRUPTERWP -WEATHERPROOF WHILE-IN-USE COVERUSB -PROVIDE WITH (2) USB-C PORTSTR -TAMPER RESISTANTHM -HORIZONTAL MOUNTINGPANELBOARD OR LOAD CENTERJUNCTION BOXFLATSCREEN TV BOX: 2-GANG, FLUSH IN WALL, HUBBELL RACO NSAV62M, WITH NSAV6C COVER. DUPLEX RECEPTACLE & SINGLE GANG DATA PORT. MOUNT AT +72", UNO.SIMPLEX RECEPTACLE -CEILING MOUNT, WALL MOUNT (+18", UNO)DUPLEX RECEPTACLE -CEILING MOUNT, WALL MOUNT (+18", UNO)QUADRUPLEX RECEPTACLE -CEILING MOUNT, WALL MOUNT (+18", UNO)DATA FLOOR BOX -RECEPTACLE FLOOR BOX WITH QUADRUPLEX RECEPTACLE -INCLUDE ALL HARDWARE/ACCESSORIES AS REQUIRED. PROVIDE COVER (COORDINATE WITH ARCHITECT FOR FLOORING TYPE AND FINISH).SPECIAL PURPOSE RECEPTACLE (MOUNT AT +18", UNO)"X" INDICATES TYPE:A -NEMA 5-20R, #12 CU;B -NEMA 5-30R, #10 CU;C -NEMA 5-50R, #8 CU;D -NEMA 6-20R, #12 CU;E -NEMA 6-30R, #10 CU;F -NEMA 6-50R, #8 CU;G -NEMA 14-20R, #12 CU;H -NEMA 14-30R, #10 CU;I -NEMA 14-50R, #8 CU;LE -LOCKING NEMA L6-30R,K -NEMA 15-20P, #12 CU;#10 CU;LL -NEMA L6-15R, #12 CU;LD -NEMA L6-20R, #12CU;L -NEMA 6-15P, #12CU;LJ -NEMA L15-30R, #10CU;DROP-DOWN RECEPTACLESURFACE MOUNTED PLUGSTRIP"X" INDICATES TYPE:A -PLUGSTRIP, POWER ONLY, OUTLET EVERY 2' OC OR AS INDICATED ON PLANB -WIREMOLD SERIES 4000 POWER AND DATAC -WIREMOLD SERIES 5000 POWER AND DATASURFACE MOUNTED RACEWAYRACEWAY CONCEALED IN WALL, FLOOR, OR CEILING IN FINISHED SPACES, EXPOSED IN UNFINISHED SPACESRACEWAY BELOW FLOOR OR BELOW GRADERACEWAY STUB-OUT WITH CAPPED ENDRACEWAY STUB-OUT WITH BRUSHED ENDGROUNDING BUSPUSHBUTTON (MOUNT AT +46", UNO)"X" INDICATES TYPE:EPO -EMERGENCY POWER OFFADA -HANDICAPPED ACCESSIBLE DOOR(DEVICE BY OTHERS)ODO -OVERHEAD DOOR OPERATOR(DEVICE BY OTHERS)DB -DOORBELL"X" INDICATES TYPE:A -4-GANG FLOOR BOX, CORROSION RESISTANT COATING FOR CONCRETE FLOORS (3" MIN. POUR DEPTH), UP TO 2" CONDUIT FEED (HUBBELL NO. CFB4G30CR, OAE)B -4-GANG FLOOR BOX FOR RAISED ACCESS FLOORS,UP TO 2" CONDUIT FEED (HUBBELL NO. AFB4G50, OAE)C -FIRE RATED POKE-THROUGH FLOOR BOX FOR ELEVATED CONCRETE SLABS, 3" DIA. CORE (HUBBELL NO. PT7FSD, OAE)D -8" DIA., FIRE RATED POKE-THROUGH FLOOR BOX FOR ELEVATED CONCRETE SLABS, UP TO 2" CONDUIT FEED (HUBBELL NO. S1R8PTFIT3, OAE)E -FLUSH, ROUND SINGLE SURFACE FLOOR BOX FOR CONCRETE FLOORS, UP TO 1" CONDUIT FEED (HUBBELL NO. B2506, OAE)F -TOMBSTONE PEDESTAL FLOOR BOX, 1" CONDUIT FEED (HUBBELL NO. 6301, OAE)ABOVE COUNTER RECEPTACLE -MOUNT AT+4" ABOVE BACKSPLASHHALF-HOT RECPTACLE (SWITCH FOR SIMPLEX)PROJECT #SHEET NUMBERREVISION:DATE618 N Wallace | Bozeman, MT 59715DRAFTNOT FOR CONSTRUCTIONThis drawing is not intended nor shall it be used for construction purposes unless the signed professional stamp of a regisered architect employed at MINARIK Architecture, Inc. is affixed above.Consultant:971-319-6249 | www.minarikarch.comProject Status:© 2024 MINARIK Architecture, IncALL RIGHTS RESERVEDThese Drawings are the Property of MINARIK Architecture, Inc and are not to be used or reproduced in any manner without prior written permission.3/14/2025 3:58:32 PM2404E0.0Evergoods.2214,2218,2200 IRON HORSE RDBozeman, MT 5971501/27/2025ELECTRICAL COVERSHEETSITE PERMIT SETSHEET LIST - ELECTRICALE0.0 ELECTRICAL COVER SHEETE0.2 ELEC - SITE PLANE0.3 PHOTOMETRIC SITE PLANE1.0 ELEC - LEVEL 1 - POWER PLANE1.1 ELEC - LEVEL 2 - POWER PLANE1.2 ELEC - ROOF PLAN - POWER PLANE1.3 ELEC - ENLARGED POWER PLANSE2.0 ELEC - LEVEL 1 - LIGHTING RCPE2.1 ELEC - LEVEL 2 - LIGHTING RCPE3.0 ELEC - LEVEL 1 - FIRE ALARM RCPE3.1 ELEC - LEVEL 2 - FIRE ALARM RCPE4.0 ELEC - ONE LINE DIAGRAME4.1 ELECTRICAL DETAILSE4.2 ELECTRICAL DETAILSE4.3 ELECTRICAL DETAILSE5.0 ELECTRICAL PANEL SCHEDULESE5.1 ELECTRICAL PANEL SCHEDULESREVISION DATE REASON FOR ISSUE03/14/2025