Loading...
HomeMy WebLinkAbout024 A3.00 BUILDING ELEVATIONST/Slab -Level 10' -0"T/PLY -Level 212' -0"T/Plate -Grid E26' -1"98765432124' - 4"13' - 8"19' - 2"12' - 10"51' - 5"11' - 6"28' - 6"8' - 7"170' - 0"4A4.003A4.001A4.002A4.005A4.0012' - 0"4' - 8 1/4"5' - 9 3/4"3' - 7"MTL-1MTL-1MTL-2MTL-2MTL-2MTL-2MTL-2MTL-2MTL-2MTL-2MTL-22" / 1'-0"W8W5W7W5W7W5W7W5W4W4W5MTL-1T/Plate -Lower16' -8 1/4"W16WD ColumnWD ColumnConcrete Board Skirt TYPGutter & DSGutter & DSGutter & DSMAX Building Height28' - 8"W10T/PLY -Mech Roof22' -6"Mechanical Screening Exceeds Height of RTUsSconce104A2" / 1'-0"26' - 1"Soffit Light TYPT/Slab -Level 10' -0"T/PLY -Level 212' -0"T/Plate -Grid E26' -1"9876543214A4.003A4.001A4.002A4.005A4.003' - 7"5' - 9 3/4"4' - 8 1/4"12' - 0"24' - 4"13' - 8"19' - 2"12' - 10"51' - 5"11' - 6"28' - 6"8' - 7"170' - 0"WD-1MTL-1MTL-1.1MTL-1WD-1W2W6W6W6W6W3W15W12W12W12W12W11W13W14W14W14W6T/Plate -Lower16' -8 1/4"114BS100AMTL-1WD-1MTL-2MTL-2MTL-2MTL-2MTL-2MTL-2W14Fire RiserWD ColumnConcrete Board SkirtT/PLY -Mech Roof22' -6"114CMTL-2ELECT MeterCT CabinetSconceSconceSconceSconceMechanical ScreeningSconceSconce15' - 0"T/Parapet15' - 0"T/Parapet26' - 1"Soffit Light TYPT/Slab -Level 10' -0"T/PLY -Level 212' -0"T/Plate -Grid E26' -1"BEDAC3' - 7"5' - 9 3/4"4' - 8 1/4"12' - 0"F4' - 0"1' - 6"20' - 6"6' - 0"28' - 11"60' - 11"2" / 1'-0"2" / 1'-0"MTL-1MTL-11A4.012A4.013A4.01W9W1W12T/Plate -Lower16' -8 1/4"MTL-2WD-1Fire RiserT/PLY -Mech Roof22' -6"WD ColumnWD ColumnSconceMechanical ScreeningExceeds Height of RTUs26' - 1"SconceSoffit Light TYPT/Slab -Level 10' -0"T/PLY -Level 212' -0"T/Plate -Grid E26' -1"BEDACF28' - 11"6' - 0"20' - 6"1' - 6"4' - 0"60' - 11"2" / 1'-0"2" / 1'-0"MTL-11A4.012A4.013A4.01T/Plate -Lower16' -8 1/4"WD-1W17W17W6W6Concrete Board SkirtDST/PLY -Mech Roof22' -6"W17Mechanical ScreeningSconce3' - 7"5' - 9 3/4"4' - 8 1/4"12' - 0"26' - 1"MTL -1Pre-Formed Metal PanelLEGEND -EXTERIOR ELEVATIONWD -1Ship-Lap Wood Siding, HorizontalMTL -2Sheet Metal Wall PanelRefer to Outline Specifications for detailsMTL -1.1Pre-Formed Metal Panel -PerforatedGENERAL NOTES1. CONTRACTOR TO VERIFY EXISTING CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION; NOTIFY ARCHITECT OF ALL DISCREPANCIES.2. CONTRACTOR TO VERIFY EXISTING UTILITY LOCATIONS PRIOR TO CONSTRUCTION.3. DIMENSIONS ARE TO FACE OF FRAMING, FACE OF CONCRETE, GRIDLINE, OR CENTERLINE OF OBJECT, U.N.O.4. DETAIL DRAWINGS OR LARGER SCALE DRAWINGS TAKE PRECEDENT OVER SMALLER SCALE DRAWINGS.5. REFERENCE STRUCTURAL FOR SHEAR WALL LOCATIONS6. INTERIOR PARTITION WALLS TO BE TYPE I-1, TYP, U.N.O. REFERENCE A0.1 FOR HORIZONTAL AND VERTICAL ASSEMBLIES7. VERIFY ALL CLEARANCES/ROUGH OPENIGNS FOR APPLIANCES PLUMBING AND EQUIPMENT8. PROVIDE BACKING OR STRAPPING FOR ALL WALL MOUNTED ACCESSORIES, FURNISHINGS, AND EQUIPMENT, VERIFY WEIGHTS AND LOCATIONS.9. REFERENCE A0.2 FOR ACCESSIBILITY STANDARDSMTL -1Pre-Formed Metal PanelWD -1 Ship-Lap Wood Siding, HorizontalMTL -2 Sheet Metal Wall PanelMTL -1.1 Pre-Formed Metal Panel -PerforatedWD -ColumnConcrete Board SkirtLEGEND -EXTERIOR ELEVATION -REALISTICAL-1 (Window & Door Frames) - Black AluminumPROJECT #SHEET NUMBERREVISION:DATE618 N Wallace | Bozeman, MT 59715This drawing is not intended nor shall it be used for construction purposes unless the signed professional stamp of a regisered architect employed at MINARIK Architecture, Inc. is affixed above.Consultant:971−319−6249 | www.minarikarch.comProject Status:© 2022 MINARIK Architecture, IncALL RIGHTS RESERVEDThese Drawings are the Property of MINARIK Architecture, Inc and are not to be used or reproduced in any manner without prior written permission.1/27/2025 2:14:40 PM2404A3.00Evergoods.2214 IRON HORSE RDBozeman, MT 5971501/27/2025BUILDINGELEVATIONSSite Plan1/8" = 1'-0"Building Elevation - East11/8" = 1'-0"Building Elevation - West21/8" = 1'-0"Building Elevation - South31/8" = 1'-0"Building Elevation - North4True NorthNSEWProject NorthBuilding Elevation: WEST -Facing Iron Horse RDBlock Frontage: OTHERFacade Transparency: "Other buildings, at least 10% of the entire façade(all vertical surfaces generally facing the street)" -Table 38.510.030.GGlazing Area: 872 SQ FTFacade Area: 4,700 SQ FT% TRANSPARENT: 18.6%Building Elevation: EAST -Facing Manley RDBlock Frontage: OTHERFacade Transparency: "Other buildings, at least 10% of the entire façade(all vertical surfaces generally facing the street)" -Table 38.510.030.GGlazing Area: 1,702 SQ FT Facade Area: 3,585 SQ FT% TRANSPARENT: 47.5%Building Elevation: NORTH -Facing Propery Line at Lot 5Closest Distance To Property Line: 5'-2"Per IBC TABLE 705.8: For Buildings 5' to less than 10', Unprotected, Sprinklered, MAX 25% Per StoryLevel 1:Facade Area: 739 SQ FTGlazing Area: 56 SQ FTGlazing Percentage: 7.5%Level 2:Facade Area: 818 SQ FTGlazing Area: 48 SQ FTGlazing Percentage: 6%REVISION DATE REASON FOR ISSUE