Loading...
HomeMy WebLinkAbout13 Evergoods Ext MTL-1CCondensedTTechnicalRReference OPEN FRAMING OR SOLID SUBSTRATE ARCHITECTURALCOMMERCIALINDUSTRIALPANEL 32" COVERAGE CUSTOM CAPABILITIES EXPOSED FASTENED  Finishes: Standard: PVDF Optional: Multi-pass Kynar®, Marblique, Plastisol, Polyester and MS Colorfast45®  Corrosion Protection: AZ55 per ASTM A 792 for unpainted Galvalume® AZ50 per ASTM A 792 for painted Galvalume® G90 per ASTM A 653 for Galvanized  Gauges: 24 ga and 22 ga  32" panel coverage, 3/4" rib height  Crisp 90º vertical box ribs on 4" centers  Panel Length: 5' minimum, 25' maximum  Exposed Fastened Panel  Optional material availablity: Stainless Steel, Copper and Aluminum  Custom capabilities include: - Perforated panels for wind screens and liner panels T16-L WALL PANEL PANEL OVERVIEW C 32" Coverage 4" Pitch3/4"  ASTM E 283 Air Leakage  ASTM E 331 Water Penetration  ASTM E 330 Structural Performance  ASTM E 1592 Structural Performance TESTING CCondensedTTechnicalRReference ©MSMC/8-2020Anchorage, AK 866.640.7663 Bay City, MI 888.777.7640 Deer Lake, PA 800.544.2577 Denver, CO 800.289.7663 Detroit Lakes, MN 888.594.1394 Fontana, CA 800.782.7953 Fort Smith, AR 877.452.3915 Independence, MO 800.747.0012 Jacksonville, FL 800.394.4419 Jefferson, OH 800.321.5833 Mocksville, NC 800.228.6119 Nashville, TN 800.251.8508 Rock Island, IL 800.747.1206 Rogers, MN 800.328.9316 Seattle, WA 800.431.3470 Sellersburg, IN 800.999.7777 Sioux Falls, SD 888.299.0024 Spokane, WA 800.572.6565 Temple, TX 800.543.4415 Woodland, CA 800.759.6019 metalsales.us.com FASTENER INFORMATION Overdriven fasteners will cause panel distortion. Panel fasteners should extend 1/2" or more past the inside face of the support material. Thick panels (ex. 18 ga) or supports (ex. 1/2" steel) may require predrilling of holes for screws. Panel Fastener: Attaching to Wood: #10-14 XL Wood Screw Attaching to Steel: #12-14 XL Self Drilling Screw Trim Fastener: 1/8" x 3/16" Pop Rivet 1/4"-14 x 7/8" XL Stitch Screw T16-L WALL PANEL ALLOWABLE UNIFORM LOADS, psffor various fastener spacings 3’ 4’ 5’ 6’ 7’ 8’ 3’ 4’ 5’ 6’ 7’ 8’ SECTION PROPERTIES Bottom in CompressionWidthinYieldksi 32 50 32 50 32 33 32 33 24 Ga 22 20 18 Sxxin3/ftIxxin4/ft Weightpsf 1.24 1.62 1.97 2.58 Top in Compression Sxxin3/ftIxxin4/ft 0.0293 0.0656 0.0300 0.0677 170 97 52 30 19 13 165 94 52 30 19 13 0.0413 0.0975 0.0424 0.1001 248 127 65 38 24 16 242 127 65 38 24 16 Inward Load Outward Load ATTACHMENT DETAIL FASTENING PATTERNS Ends of Panel Field of Panel Panel Fastener Panel Fastener Panel Fastener 1. Theoretical section properties have been calculated per AISI 2016 'North American Specification for the Design of Cold-Formed Steel Structural Members'. Ixx and Sxx are effective section properties for deflection and bending. 2. Allowable load is calculated in accordance with AISI 2016 specifications considering bending, shear, combined bending & shear and deflection. Allowable load does not address web crippling, fasteners, support material or load testing. Panel weight is not considered. 3. Allowable load considers the 3 or more equal spans condition. 4. Deflection consideration is limited by a maximum deflection ratio of L/180 of span. 5. Allowable loads do not include a 1/3 stress increase for wind.