Loading...
HomeMy WebLinkAbout034_E4.0_Electrical SchedulesPROJECT #SHEET NUMBERREVISION:DATE618 N Wallace | Bozeman, MT 59715DRAFTNOT FOR CONSTRUCTIONThis drawing is not intended nor shall it be used for construction purposes unless the signed professional stamp of a regisered architect employed at MINARIK Architecture, Inc. is affixed above.Consultant:971−319−6249 | www.minarikarch.comProject Status:© 2024 MINARIK Architecture, IncALL RIGHTS RESERVEDThese Drawings are the Property of MINARIK Architecture, Inc and are not to be used or reproduced in any manner without prior written permission.2/7/2025 1:52:41 PM2403E4.0Mill Building RenovationBangtail Partners, LLCBozeman, Montana02/07/2025ELECTRICALSCHEDULESSite Permit SetLUMINAIRE SCHEDULETYPEMARKDESCRIPTION MANUFACTURER MODELAPPARENTLOADCRI CCT LUMENSDIMENSIONS(LxWxH)LENS/REFLECTOR VOLTAGE OPTIONSBB1 BOLLARD ACUITY BVA11B-L1LK2A-LD1-AMB-MVOLT-BKT 8 VA80 1800 262 lm 11"x6"x42" LD1 120EL1 SLOT LED LUMINAIRE FOCAL POINT FSM2L-FL-125LF-_30K-1C-UNV-LD1-XFN-EM-WH-8ft 11 VA 80 3000 125 lm 8'x2.5"x4.5" FLUSH 120 EMERGENCY BATTERY PACKEWP1 SURFACE WALLMOUNT ACUITY WDGE2 LED-P4-30K-80CRI-T1S-MVOLT-SRM-E20WC-PE 47 VA 80 3000 3729 lm 11.5"x7"x9" T1S 120 EMERGENCY INTEGRAL BATTERYEWP3 SURFACE WALLMOUNT ACUITY WDGE2 LED-P0-30K-80CRI-T1S-MVOLT-SRM-E20WC-PE 7 VA 80 3000 636 lm 11.5"x7"x9" T1S120 EMERGENCY INTEGRAL BATTERYREMARKS:TOTAL EST. DEMAND:0.0 ATOTAL CONN.:0.0 ATOTAL EST. DEMAND:0 VATOTAL CONN. LOAD:0 VALOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS12345BLANK- ARC FAULT CIRCUIT INTERRUPTER- GROUND FAULT CIRCUIT INTERRUPTER- COMBINATION ARC/GROUND FAULT CIRCUIT INTERRUPTER- EQUIPMENT PROTECTIVE DEVICE- LOCKABLE BREAKER- STANDARD BREAKERBREAKER TYPE LEGEND:TOTAL AMPS:0.0 A 0.0 ATOTAL LOAD:0 VA 0 VA41 4239 4037 3835 3633 3431 3229 3027 2825 2623 2421 2219 2017 1815 1613 1411 129 107 85 63 41 2CKT CIRCUIT DESCRIPTIONBREAKERTYPETRIP POLES A B POLES TRIPBREAKERTYPECIRCUIT DESCRIPTION CKTA) CONTRACTOR SHALL PROVIDE ARC-FAULT PROTECTION PER NEC 210.12 AND GFI PROTECTION PER NEC 210.8 WITH EITHER A BREAKER OR DEVICE RATED TO PROVIDE SUCHPROTECTION, WHETHER SHOWN ON THESE DRAWINGS OR NOT.B) PROVIDE HANDLE LOCK FOR DISCONNECTING MEANS WHERE LOCAL DISCONNECTS ARE NOT APPLICABLE.NOTES:ENCLOSURE:NEMA 1MCB RATING:200 AMOUNTING:SURFACEWIRES:3MAINS RATING:200 ASUPPLY FROM:MDPPHASES:1MAINS TYPE:MLOLOCATION:MECH 202VOLTS:120/240 SingleAVAILABLE FAULT CURRENT:SEE ONE-LINE DIAGRAMBranch Panel: AREMARKS:TOTAL EST. DEMAND:0.0 ATOTAL CONN.:0.0 ATOTAL EST. DEMAND:0 VATOTAL CONN. LOAD:0 VALOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS12345BLANK- ARC FAULT CIRCUIT INTERRUPTER- GROUND FAULT CIRCUIT INTERRUPTER- COMBINATION ARC/GROUND FAULT CIRCUIT INTERRUPTER- EQUIPMENT PROTECTIVE DEVICE- LOCKABLE BREAKER- STANDARD BREAKERBREAKER TYPE LEGEND:TOTAL AMPS:0.0 A 0.0 ATOTAL LOAD:0 VA 0 VA41 4239 4037 3835 3633 3431 3229 3027 2825 2623 2421 2219 2017 1815 1613 1411 129 107 85 63 0 VA 0 VA 41SPD -- 30 A 20 VA 0 VA2 200 A PANEL 'A'2CKT CIRCUIT DESCRIPTIONBREAKERTYPETRIP POLES A B POLES TRIPBREAKERTYPECIRCUIT DESCRIPTION CKTA) CONTRACTOR SHALL PROVIDE ARC-FAULT PROTECTION PER NEC 210.12 AND GFI PROTECTION PER NEC 210.8 WITH EITHER A BREAKER OR DEVICE RATED TO PROVIDE SUCHPROTECTION, WHETHER SHOWN ON THESE DRAWINGS OR NOT.B) PROVIDE HANDLE LOCK FOR DISCONNECTING MEANS WHERE LOCAL DISCONNECTS ARE NOT APPLICABLE.NOTES:ENCLOSURE:NEMA 3RMCB RATING:400 AMOUNTING:SURFACEWIRES:3MAINS RATING:400 ASUPPLY FROM:UTILITYPHASES:1MAINS TYPE:MCBLOCATION:EXTERIORVOLTS:120/240 SingleAVAILABLE FAULT CURRENT:SEE ONE-LINE DIAGRAMBranch Panel: MDPREVISION DATE REASON FOR ISSUE02/07/2025