HomeMy WebLinkAbout016b_4.1_Irrigation Details and NotesIRRIGATION NOTES: 1.CONTRACTOR RESPONSIBLE TO INFORM LANDSCAPE ARCHITECT OF ANY DISCREPANCIES OR CHANGES REQUIRED TO THE IRRIGATION DESIGN. IF CONTRACTOR MAKES CHANGES TO THE IRRIGATION DESIGN WITHOUT APPROVAL FROM THE LANDSCAPE ARCHITECT. CONTRACTOR TO VERIFY STATIC PRESSURE IN THE FIELD PRIOR TO BIDDING AND CONSTRICTION. IN THE EVENT OF DISCREPANCY, CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT IN WRITING OF ANY CHANGES NECESSARY TO PROVIDE THE REQUIRED OPERATIONAL PRESSURE AND FLOW. CONTRACTOR ASSUMES FULL RESPONSIBILITY, COSTS, AND LIABILITIES ASSOCIATED WITH THOSE FIELD CHANGES OF THE IRRIGATION SYSTEM DESIGN AND PERFORMANCE. 2.CONTRACTOR SHALL INSPECT THE SITE AND VERIFY CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION. 3.IRRIGATION PLANS ARE SCHEMATIC REPRESENTATION ONLY. PLACE LINES IN A COMMON TRENCH WHENEVER POSSIBLE. FIELD ADJUST LINES TO AVOID CONFLICT WITH UTILITIES. 4.IRRIGATION IS COORDINATED WITH THE PLANTING PLAN AND SITE IMPROVEMENTS, COORDINATION IRRIGATION LAYOUT WITH FINAL INSTALLED LOCATION OF PLANT MATERIALS. DO NOT ALTER IRRIGATION LAYOUT OR VALVE LOCATION WITHOUT WRITTEN APPROVAL FROM THE LANDSCAPE ARCHITECT. NOTIFY LANDSCAPE ARCHITECT IF DISCREPANCIES OCCUR BETWEEN THE PLANS AND FIELD CONDITIONS. 5.PRIOR TO COMMENCING WORK, CONTRACTOR SHALL SCHEDULE A PRE-INSTALLATION MEETING WITH THE CITY OF BOZEMAN WATER CONSERVATION DIVISION. CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT OF SCHEDULED MEETING NO LESS THAN 2 WEEKS PRIOR. 6.POINT OF CONNECTION (POC): EXISTING PRIVATE WELL WITH STATIC PRESSURE OF 60 PSI, LOCATION SHOWN APPROXIMATE. VERIFY IN THE FIELD PRIOR TO INSTALLATION. TAP LINE AND SET WATER METER. THIS SYSTEM IS DESIGNED FOR A 1-1/2" POC WITH 60PSI STATIC PRESSURE, 53.1 GPM DESIGN CAPACITY AND MAXIMUM WORKING PRESSURE OF 40 PSI. 7.ALL TEMPORARY IRRIGATION AREAS SHALL USE IRRIGATION QUICK COUPLERS AS INDICATED, VIA TEMPORARY ABOVEGROUND OVERHEAD SPRAY. ONCE PLANT MATERIALS HAVE BEEN ESTABLISHED, TEMPORARY IRRIGATION EQUIPMENT SHALL BE REMOVED. 8.THE CONTRACTOR SHALL PROVIDE FINAL IRRIGATION SCHEDULING PROGRAMMED TO OPERATE WITHIN THE CITY OF BOZEMAN'S WATERING WINDOW OUTLINE IN BMC 40.02.1290. 9.CONTRACTOR RESPONSIBLE FOR SCHEDULING A PUNCH-LIST SUBSTANTIAL COMPLETION INSPECTION AND FINAL COMPLETION INSPECTION WITH LANDSCAPE ARCHITECT. PRIOR TO INSPECTIONS, IRRIGATION MAINLINE TO BE CHARGED FOR A MINIMUM TWO HOURS AND VALVE BOXES AND EQUIPMENT HOUSINGS SHALL BE OPEN TO VIEW. 10.CONTRACTOR RESPONSIBLE FOR FURNISHING IRRIGATION AS-BUILTS TO LANDSCAPE ARCHITECT TWO WEEKS FROM COMPLETION OF FINAL COMPLETION INSPECTION. 11.PROVIDE PRESSURE REDUCING VALVE UP STREAM OF BACKFLOW ASSEMBLY IF PRESSURE EXCEEDS 80 PSI. REDUCE TO 65 PSI STATIC PRESSURE. 12.ALL PIPE SIZES INDICATED ARE MINIMUMS. CONTRACTOR MAY NOT DECREASE PIPE SIZE. LARGER PIPE SIZES MAY BE USED AT NO ADDITIONAL COST TO OWNER. PIPE SIZES INCREASE IN SIZE DOWNSTREAM OF NEXT PRAY HEAD AS SHOWN. 13.INSTALL ALL IRRIGATION PIPE AND CONTROL WIRE IN MINIMUM 4" PVC SLEEVE BELOW ALL PAVED SURFACES UNLESS OTHERWISE INDICATED ON THE PLANS. INSTALL SLEEVES PRIOR TO PLACEMENT OF PAVEMENTS AND PAVEMENT SUB-BASE. WHERE PAVEMENT EXISTS, BORE AND PLACE SLEEVES. 14.CONTRACTOR TO PROGRAM AUTOMATIC CONTROLLER TO ALLOW FOR THE EQUIVALENT OF 1" OF WATER PER WEEK FOR ALL PLANTINGS UNLESS OTHERWISE INDICATED WITHIN THE PLANS WATERING SCHEDULE, OR PER SITE AND PLANTING NEEDS FOR BEST PLANT HEALTH. 15.ALL PVC PIPES SHALL BE TRENCHED UNLESS APPROVED IN WRITING TO ALLOW TO BE PULLED. POLY PIPE MAY BE PULLED. PROVIDE POSITIVE DRAINAGE OF MAINLINE. PLACE MANUAL DRAIN AT LOW POINTS IN MAINLINE. IDENTIFY LOCATIONS OF DRAINS ON AS-BUILTS. 16.CONTRACTOR TO INSTALL CONTROLLER AND ACCESSORIES AS REQUIRED. CONTRACTOR FURNISH CONTROL WIRES FROM VALVES TO CONTROLLER. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION FROM EXISTING ELECTRICAL SERVICE AND CONNECTION TO CONTROLLER. INSTALL ONE (1) ADDITIONAL RED CONTROL WIRE AND ONE (1) ADDITIONAL WHITE CONTROL WIRE FROM CONTROLLER TO END OF MAINLINE. 17.ALL TREES TO BE ON A DEDICATED DRIP ZONE FOR DROUGHT PREPARATION. 18.WATER BUDGETS AND PROJECTIONS HAVE BEEN PREPARED BASED UPONE ASSOCIATED PROJECTED WATER USE UPON CITY OF BOZEMAN WATER CONSERVATION DISTRICT LANDSCAPE & IRRIGATION STANDARDS, AND THE CITY OF BOZEMAN PROVIDED WATER BUDGET CALCULATOR. THE BUDGETS AND PROJECTIONS ASSUME BEST MANAGEMENT PRACTICES FOR IRRIGATION SYSTEM MAINTENANCE. FIELD STUDIO LANDSCAPE ARCHITECTS IS NOT RESPONSIBLE AND ACCEPTS NO LIABILITY FOR THE ACTUAL WATER USAGE VARIATION THAT IS A RESULT OF FIELD MODIFICATION TO THE SYSTEM NOT MATCHING CONSTRUCTION DOCUMENTS, IMPROPER MAINTENANCE AND OPERATION OF THE SYSTEM, WASTE DUE TO SYSTEM DAMAGE OR VANDALISM, OR WEATHER CONDITIONS THAT DEVIATE FROM PUBLISHED 30-YEAR HISTORICAL AVERAGES DATA. Scale:1" = 20' 40'20'10'0' DATE ●,SSUE PERMIT SET DOCUMENT REUSE: This document is the property of Field Studio Landscape Architects PLLC. The ideas and design incorporated on this document shall not be used for any other project without written authorization of Field Studio Landscape Architects PLLC. SHEET OF PRO-ECT NUMBER: S+EET T,TLE 7 2 2 N .R O U S E A V E . B O Z E M A N , M T 5 9 7 1 5 (4 0 6 )5 5 1 -2 0 9 8 w w w .f i e l d s t u d i o l a .c o m MILL BUILDING RENOVATIONLOTS 5-28, BLOCK 105. BOZEMAN, MT2416.00 L-4.10 IRRIGATION DETAILS & NOTES 7 7 2025.02.07 SITE PL REVIEW 2025.03.17 SITE PL REV. 2025.04.09 SITE PL REV. REDUCED PRESSURE BACKFLOW DEVICE 1" = 1'-0" SERVICE SIDE MAINLINE SIDE 1 2 3 4 5 6 7 REDUCED PRESSURE BACKFLOW DEVICE AS SPECIFIED1 GALVANIZED UNIONS AT EACH SIDE2 GALVANIZED RISERS3 CONCRETE THRUST BLOCKS, 90 LBS OF CONCRETE EACH4 GALVANIZED NIPPLES AND ELL AS REQUIRED5 GALVANIZED ELL AND NIPPLE, TYPICAL EACH SIDE6 PVC COUPLER AND SCH. 80 TOE NIPPLE, TYPICAL EACH SIDE7 1 FX-IR-FX-BACK-03 MASTER CONTROL VALVE 1 1/2" = 1'-0" FINISHED GRADE. SET BOX 2" ABOVE GRADE AT SHRUBS. SET BOX FLUSH TO GRADE AT TURF. A.E.P.RECTANGULAR BOX #1015 A.E.Q.WITH 6" EXTENSIONS AS REQUIRED. WATER PROOF WIRE CONNECTORS ON 30" LOOPED WIRES. 1/2" WIRE CLOTH GOPHER SCREEN, WRAP UP SIDES. PVC MAIN LINE.6X2X16 CONC. BLOCK CAPS, ONE EACH SIDE (2 TOTAL) SXT SCHEDULE 80 NIPPLES VALVE INLET SIZE. PVC CONDUIT FOR CONTROLLER WIRES.18" MINIMUM BELOW GRADE.12" MIN. BELOW GRADE.2 FX-IR-FX-MAST-06 NOTES: 1- LOCATE VALVE BOXES IN PLANTING AREAS. 2- WRAP VALVE BOX WITH A MINIMUM OF 3 MIL THICK PLASTIC AND SECURE IT USING DUCT TAPE OR ELECTRICAL TAPE. 3- ALL THREADED CONNECTION TO BE MADE USING TEFLON TAPE. 4- ALL CHANGES IN ELEVATION SHALL BE MADE USING SCH. 40 PVC 45° ELBOWS. 6" MIN 12" MAX BALL VALVE 3" AND SMALLER 1 1/2" = 1'-0" THREADED BALL VALVE. (SEE IRRIGATION LEGEND FOR MAKE AND MODEL). SCH. 80 PVC MALE ADAPTER. FINISHED GRADE. RECTANGULAR VALVE BOX WITH LOCKING LID. PAVEMENT. SCH. 80 PVC UNION SXS. SCH. 80 PVC NIPPLE TXS. MAINLINE. THREE INCH (3") THICK LAYER OF PEA GRAVEL OR APPROVED 38" WELDED WIRE MESH. SCH. 40 PVC 45° ELBOW. FOUR (4) 4" X 8" BRICKS. 3 FX-IR-FX-SHUT-01 1 2 4 5 7 8 9 INTERIOR WALL MOUNT CONTROLLER W/ J-BOX 1" = 1'-0" 6 24" MIN.18" MIN. 3 SET CONTROLLER 60" ABOVE FINISHED GRADE UNLESS OTHERWISE SPECIFIED 1 CONTROLLER AS SPECIFIED. SECURELY BOLT CONTROLLER TO WALL. INSTALL BACKUP BATTERIES AS REQUIRED. GROUND AS PER MANUFACTURER SPECIFICATIONS 2 EXTERNAL WALL3 1/2" DIAMETER RIGID STEEL CONDUIT FOR 110 VAC ELECTRICAL SOURCE. INSTALL AS PER LOCAL ELECTRICAL CODES 4 2" DIAMETER GRAY PVC CONDUIT FOR RCV WIRES 5 LB JUNCTION BOX6 FINISHED FLOOR LEVEL7 LONG SWEEP ELL8 18' MIN. BEYOND STRUCTURE, OR TO BOX AS PER PLANS 9 4 FX-IR-FX-CONT-11 INTERIOR WALL X2-400 CONTROLLER (INDOOR) 1 1/2" = 1'-0" *NOTE* SPECIFY 2, 4, 6 OR 8 STATION MODEL CONTROLLER. MOUNT CONTROLLER WITH LCD SCREEN AT EYE LEVEL. PLUG-IN TRANSFORMER SHALL BE CONNECTED TO GROUNDED 110 VAC OUTLET. MODEL X2-400 CONTROL WIRE IN ELECTRICAL CONDUIT. SIZE AND TYPE PER LOCAL CODE PLUG-IN TRANSFORMER 5 FX-IR-HUNT-CONT-32 WIRELESS RAIN/FREEZE-CLIK 3" = 1'-0" NOTE: MOUNT SENSOR ON ANY SURFACE WHERE IT WILL BE EXPOSED TO UNOBSTRUCTED RAINFALL, BUT NOT IN PATH OF SPRINKLER SPRAY, NO MORE THAN 1000' FROM RECEIVER UNIT. MOUNT UNIT NO FURTHER THAN 6' FROM CONTROLLER. WRC RECEIVER MODEL WRFC MOUNTING WALL 6 FX-IR-HUNT-SENS-18 DRIPLINE FLUSH VALVE AT GRADE 3" = 1'-0" COMPRESSION TEE AS OCCURS. DRIPLINE STAKING AS NOTED. DRIPLINE WITH EMITTERS AS NOTED. DRIPLINE STAKE AT COUPLER. DRIPLINE COMPRESSION COUPLER. FLUSH CAP AT GRADE. 8 FX-IR-FX-DRIP-07 QUICK COUPLING VALVE IN BOX 1 1/2" = 1'-0" 10" DIAMETER VALVE BOX. HEAD BRAND "QVC" ON LID WITH 2" HIGH CHARACTERS. QUICK COUPLING VALVE AS SPECIFIED. GALV.NIPPLE, LENGTH AS REQ. 6" DEEP LAYER OF 3/4" CRUSHED ROCK. 12" PVC SCHEDULE 80 NIPPLE. 1/2" X 36" GALV STEEL PIPE. TWO STAINLESS STEEL CLAMPS. 3" PVC SCHEDULE 80 NIPPLE. THREE PVC SCH 80 ELLS. 12" MAX 6" MIN.1" MIN2" MAXFINISHED GRADE. FLUSH IN LAWN AREAS. 2" IN SHRUB AREAS. 9 FX-IR-FX-QUIC-03 13 GPH DRIPLINE RING NTS DRIPLINE TO LATERAL "XPANDO" ADAPTER CONNECTION DETAIL NOTE: PLACE TIE DOWN STAKES EVERY 3 FT. IN SAND, 4 FT. IN LOAM, AND 5 FT. IN CLAY, AS WELL AS AT ALL CHANGE OF DIRECTION SUCH AS AT TEES OR ELLS. 1 13 12 11 3 10 9 3 1 2 8 3 3 4 5 7 LATERAL SUPPLY PIPE, SIZE AND TYPE PER PLAN1 DRIPLINE CONNECTION TO BELOW GRADE LATERAL PIPE, SEE DRIPLINE TO LATERAL "XPANDO" ADAPTER CONNECTION DETAIL. 2 1/2" PLOYETHYLENE BLANK TUBING, AS REQUIRED. 3 BARB CROSS INSERT FITTING.4 BARB TEE INSERT FITTING.5 6 PLANT TRUNK.7 8 DRIPLINE BARBED INSERT ELL.9 RATCHET CLAMP AT ALL BARBED CONNECTIONS, ANTELCO PART NO. 44345. 10 INSERT ADAPTER, ANTELCO "XPANDO" 13MM X 14MM, PART NO. 45595. 11 13MM ANTELCO "CAPO: RUBBER GROMMET, NO. 45735. 12 HOLE IN LATERAL PIPE WHERE REQUIRED. YOU MUST USE A "FORSTNER" DRILL BIT FOR DRILLING INTO PVC. REMOVE ANY EXCESS BURRS OR ROUGH EDGES. 13 8 TYPICAL ANTELCO ASTA TIE-DOWN STAKE, SEE NOTES. 6 AT-GRADE DRIPLINE, INNER RING 12" FROM PLANT, OUTTER RING 30" FROM PLANT. DRIPLINE TO BE 0.9GPH EMITTERS AT 12" O.C. 6 4 " 24"10" 9 FX-IR-FX-EMIT-01 ICZ-101 DRIP CONTROL ZONE 1 1/2" = 1'-0" 18-24" COILED WIRE WATERPROOF CONNECTORS (2) DRIP ZONE KIT MODEL ICZ-101-XX WITH FILTER (TIP 45 DEGREES) REGULATOR 25 OR 40 PSI FINISH GRADE JUMBO VALVE BOX SCH 80 T.O.E. NIPPLE (2) MAIN LINE PIPE & FITTINGS BRICK SUPPORTS (4) 3/4" MINUS WASHED GRAVEL 10 FX-IR-HUNT-DRIP-18 2 2