Loading...
HomeMy WebLinkAbout013_L.02_Planting NotesGENERAL PLANTING SPECIFICATIONS 1.ALL DISTURBED AREAS, INCLUDING CONSTRUCTION ACCESS, TO RECEIVE TOPSOIL, SEED, AND IRRIGATION PER LANDSCAPE PLAN. ANY ADDITIONAL DISTURBANCE AREAS NOT SHOWN IN THE PLANS CREATED DURING CONSTRUCTION WILL BE RESTORED. CONTRACTOR TO VERIFY ALL AREA TAKE-OFFS AND PROVIDE TO LANDSCAPE ARCHITECT. 2.ENSURE IRRIGATION SYSTEM IS INSTALLED, TESTED, AND WORKING PROPERLY PRIOR TO ANY TREE, SHRUB, OR PERENNIAL PLANTING. IN AREAS WHERE IRRIGATION INSTALLATION MUST TAKE PLACE AFTER SEEDING, CONTRACTOR IS TO RE-SEED AND RE-PLANT AREAS DISTURBED DURING THIS WORK. 3.ENSURE ALL BACK FILL, FINE GRADING, AND ADJACENT HARDSCAPE WORK IS COMPLETE AND REVIEWED BY LANDSCAPE ARCHITECT BEFORE SEEDING OR PLANTING. 4.UTILITIES: DETERMINE LOCATION OF ABOVE GRADE AND UNDERGROUND UTILITIES AND PERFORM WORK IN A MANNER WHICH WILL AVOID DAMAGE. HAND EXCAVATE, AS REQUIRED. MAINTAIN GRADE STAKES UNTIL REMOVAL IS MUTUALLY AGREED UPON BY PARTIES CONCERNED. CONTRACTOR SHALL BE RESPONSIBLE FOR UTILITY LOCATING, REPAIR OF UTILITIES DAMAGED BY CONTRACTOR, AND ESTABLISHMENT OF GRADE CONTROLS. 5.EXCAVATION: WHEN CONDITIONS DETRIMENTAL TO PLANT GROWTH ARE ENCOUNTERED, SUCH AS RUBBLE FILL, ADVERSE DRAINAGE CONDITIONS, OR OBSTRUCTIONS, NOTIFY LANDSCAPE ARCHITECT BEFORE PLANTING. 6.FIELD MEASUREMENTS: VERIFY ACTUAL GRADE ELEVATIONS, SERVICE AND UTILITY LOCATIONS, IRRIGATION SYSTEM COMPONENTS AND DIMENSIONS OF PLANTINGS AND CONSTRUCTION CONTIGUOUS WITH NEW PLANTINGS BY FIELD MEASUREMENTS BEFORE PROCEEDING WITH PLANTING AND SEEDING WORK. 7.SQUARE FOOTAGES (SF) ARE APPROXIMATE AND BASED ON PLAN TAKE-OFFS. CONTRACTOR IS RESPONSIBLE FOR FIELD MEASURING ALL PLANTING AREAS. 8.COORDINATE INSTALLATION OF PLANTING MATERIALS DURING NORMAL PLANTING SEASONS FOR EACH TYPE OF PLANT MATERIAL REQUIRED. 9.ALL PLANTS SHALL BE TRUE TO NAME AND MEET ALL CONDITIONS OF THESE SPECIFICATIONS. ANY PLANT WHICH IS NOT TRUE TO NAME AS INDICATED BY FORM, LEAF, FLOWER, OR FRUITING CHARACTERISTICS SHALL BE REPLACED AT THE CONTRACTOR’S EXPENSE. 10.CONTRACTOR TO NOTIFY LANDSCAPE ARCHITECT TWO WEEKS PRIOR TO PLANT MATERIAL BEING DELIVERED TO THE SITE FOR INSPECTION/APPROVAL. 11.LANDSCAPE ARCHITECT RESERVES THE RIGHT TO INSPECT AND REJECT PLANT MATERIAL AT ANY POINT FROM DELIVERY THROUGH WARRANTY PERIOD. CONTRACTOR TO REPLACE MATERIAL DURING CURRENT PLANTING WINDOW. WEED MANAGEMENT NOTES 1.LANDSCAPE ARCHITECT RECOMMENDS DEVELOPING A COMPREHENSIVE LANDSCAPE WEED MANAGEMENT PLAN. A WEED MANAGEMENT CONTRACTOR MUST BE ABLE TO VISIT THE SITE REGULARLY AND OFTEN FOR BOTH RAPID RESPONSE AND ONGOING CONTROL OF NOXIOUS AND NUISANCE WEEDS DURING THE NATIVE VEGETATION ESTABLISHMENT PERIOD. 2.RESTORATION AREAS WITH EXISTING WEED GROWTH SHALL BE DISKED IN EARLY SPRING AND TREATED SOON AFTER FIRST FLUSH OF WEEDS. SEEDING AND PLANTING SHALL NOT TAKE PLACE IN THESE AREAS UNTIL TREATMENT REGIME IS COMPLETE. CONTRACTOR TO MEET WITH LANDSCAPE ARCHITECT IN SPRING TO EVALUATE AND DETERMINE PLAN PRIOR TO ANY PLANTING OR SEEDING ACTIVITIES. 3.PERENNIAL THISTLES AND OTHER PERENNIAL WEEDS SHOULD BE TREATED WITH APPROPRIATE HERBICIDE IN THE FALL TOPSOIL & FERTILIZER SPECS 1.ALL LANDSCAPE AREAS (TURF AND SEEDING) MUST HAVE 6" OF TOPSOIL SOURCED FROM THE SITE, MINIMUM. THE MINIMUM TOPSOIL QUALITY REQUIREMENTS PER CITY OF BOZEMAN MUNICODE SHALL BE MET BY PERFORMING A SOIL TEST AND AMEND THE EXISTING SOIL AS RECOMMENDED BY THE SOIL TEST. SOIL FERTILITY SHALL BE TESTED BY A CERTIFIED TESTING LAB, CSU'S SOIL, WATER AND PLANT TESTING LABORATORY OR APPROVED EQUAL: (970)-491-5061. SOIL TESTS SHALL BE SUBMITTED TO LANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO INSTALLING AND/OR AMENDING SOIL. 2.WHERE GRADING HAS ALREADY BEEN COMPLETED CONTRACTOR TO PREPARE EXISTING SOIL PER SOIL TEST RECOMMENDATION TO MEET CITY SOIL REQUIREMENTS. 3.CONTRACTOR TO VERIFY SUITABILITY OF SURFACE SOIL TO PRODUCE TOPSOIL MEETING REQUIREMENTS AND AMEND AS RECOMMENDED BY THE SOIL TEST RESULTS. IF INSUFFICIENT QUANTITIES OF TOPSOIL EXIST, SUPPLEMENT WITH IMPORTED TOPSOIL PURSUANT TO THE RECOMMENDATIONS OF THE SOIL TEST RESULTS. 4.TOPSOIL IN SEED ZONES: LANDSCAPE ARCHITECT HAS TESTED EXISTING ONSITE SOILS IN SEVERAL LOCATIONS. TEST RESULTS ARE AVAILABLE TO CONTRACTOR. PREFERRED SPECIFICATIONS FOR TOPSOIL MEET THE FOLLOWING PARAMETERS: ASTM D 5268, pH RANGE OF 5.5 TO 8.0, 4 PERCENT ORGANIC MATERIAL MIN., FREE OF STONES 1 INCH OR LARGER, REFUSE, PLANT, ROOTS, STICKS, NOXIOUS WEED SEEDS, SALT, STERILANTS OR OTHER MATERIAL WHICH WOULD BE DETRIMENTAL TO SEED GERMINATION. TOPSOIL SHALL HAVE SALTS OF LESS THAN 2 MMHOS/CM AND SODIUM ABSORPTION RATIO OF LESS THAN 12. IN AREAS WHERE SOIL TEST RESULTS ARE OUTSIDE OF THIS RANGE, CONTRACTOR TO PROPOSE RECOMMENDATIONS FOR FERTILIZER, AMENDMENT, AND IRRIGATION WITH LANDSCAPE ARCHITECT. 4.1.LANDSCAPE CONTRACTOR TO PROVIDE LANDSCAPE ARCHITECT WITH SOIL TEST REPORT FOR APPROVAL PRIOR TO PLACEMENT OF ANY TOPSOIL. REPORTS MAY NOT BE MORE THAN THREE MONTHS OLD. 5.GENERAL SOIL PREPARATION: CONTRACTOR TO APPLY FERTILIZER DIRECTLY TO SUBGRADE AND LOOSEN SUBGRADE TO A MINIMUM OF 6 INCHES. MECHANICALLY RIP OR DISK SUBSOIL IN ALL AREAS TO BE PLANTED TO A MINIMUM DEPTH OF 6-INCHES PRIOR TO PLACING TOP SOIL AND SOIL AMENDMENTS. SPREAD PREPARED TOPSOIL (SEE #3 ABOVE) 1/2 THE THICKNESS OVER LOOSENED SUBGRADE. DO NOT SPREAD IF PLANTING SOIL OR SUBGRADE IS FROZEN OR MUDDY. MIX INTO TOP 6" OF SUBGRADE. SPREAD REMAINDER OF PLANTING SOIL EVENLY OVER AREA TO BE PLANTED OR SEEDED. IN AREAS TO BE DRILL SEEDED, RIPPING AND DISKING IS NOT RECOMMENDED. 6.IN ALL AREAS TO BE PLANTED AND SEEDED, REMOVE EXISTING WEEDS BY MOWING, RAKING, AND OTHER METHODS. AVOID COMPACTING SOILS DURING THIS ACTIVITY. REFER TO WEED MANAGEMENT NOTES. 7.SOIL PREPARATION FOR SEED AREAS: SAME AS GENERAL SOIL PREPARATION PLUS SOIL SHALL BE TEXTURIZED PARALLEL TO THE CONTOUR OF THE PLANTING BED TO CREATE A ROUGH SURFACE. IN AREAS TO BE DRILL SEEDED, MINIMIZE DISTURBANCE TO SOIL TO PREVENT BRINGING ADDITIONAL WEED SEED TO THE SURFACE. 8.COMPACT PLANTING SOIL TO A MAXIMUM PROCTOR DENSITY OF 75% BEFORE SEEDING AND PLANTING. ANY SETTLING OF TOPSOIL TO BE ADDRESSED DURING WARRANTY PERIOD. 9.POSITIVE SURFACE DRAINAGE: FINISH AND FINE GRADE THE PROJECT AREA TO ESTABLISH AN EVEN AND WELL MATCHED GRADIENT OVER THE ENTIRE SURFACE. PROVIDE POSITIVE SURFACE DRAINAGE, WITH NO DEPRESSIONS, SETTLING, OR IRREGULARITIES IN THE FINISHED GRADE. 10.TRANSITIONAL AREAS: AT ANY TRANSITIONAL POINT OR LINE WHERE ONE PLANE INTERSECTS ANOTHER, SUCH AS FROM A SLOPING AREA OR BERM TO A LEVEL AREA, A SMOOTH AND GENTLE TRANSITION SHALL BE MADE. THERE SHALL BE NO ABRUPT CHANGES IN GRADE UNLESS SPECIFICALLY NOTED OTHERWISE. MATCH THE GRADES OF NEW WORK WITH EXISTING AREAS OUTSIDE THE PROJECT AREA. 11.SPREAD FERTILIZERS AT RATES INDICATED: 11.1.SEEDED/ SODDED AREAS: REFER TO SOIL TEST LAB RECOMMENDATIONS FOR FERTILIZER RECOMMENDATIONS 11.2.APPLY BIOSOL FORTE 7-2-1 GRANULAR (OR APPROVED EQUAL) AT A RATE OF 1000 LBS/ACRE AND MYCROAPPLY ENDO (OR APPROVED EQUAL) AT A RATE OF 20 LBS/ACRE. APPLY FERTILIZERS BY BROADCAST METHOD ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. SEEDING SPECIFICATIONS 1.CONTRACTOR TO LOCATE UTILITIES PRIOR TO SEED BED PREPARATION ACTIVITIES. 2.LANDSCAPE ARCHITECT TO PAINT/MARK TRANSITIONS OF SEED MIX TYPES. 3.CONTRACTOR TO INDICATE TO LANDSCAPE ARCHITECT AREAS THAT WILL BE DRILL, BROADCAST OR HYDROSEEDED AND GAIN APPROVAL BEFORE BEGINNING WORK. 4.THE SEED BED SHALL BE PREPARED NOT MORE THAN 3 DAYS PRIOR TO THE INSTALLATION OF SEED, PLUGS, OR SOD BY LOOSENING THE SOIL TO A DEPTH OF NOT LESS THAN 2” NOR MORE THAN 4” BY DISKING, HARROWING OR TILLING. SURFACE CRUSTING CAUSED BY WATER DURING THE INTERIM MUST BE LOOSENED PRIOR TO THE SEEDING OPERATION. AREAS TO BE DRILL SEEDED IN FALL 2018 SHALL NOT BE DISKED OR TILLED TO AVOID BRINGING WEED SEEDS TO THE SURFACE. 5.ALL SOIL EROSION SHALL BE REMEDIED PRIOR TO THE SEEDING OR PLANTING OPERATION 6.FOR BROADCAST AREAS, HAND BROADCAST SEED AND RAKE INTO SOIL 1/4" TO 1/2" DEPTH OVER A PREPARED SEED BED OF MINIMUM DEPTH OF 6" (REFER TO TOPSOIL, PLANTER MIX & FERTILIZER NOTES). SEEDING SHALL BE DONE IN 2 SEPARATE APPLICATIONS CROSSING THE AREA AT RIGHT ANGLES TO ONE ANOTHER TO GUARANTEE EVEN COVERAGE. ROLL SLIGHTLY AND WATER WITH FINE SPRAY. 7.APPLY WEED-FREE STRAW MULCH AFTER PLANTING. MULCH TO BE CLEAN, WHEAT STRAW CERTIFIED FREE OF NOXIOUS WEEDS AND HAVING STEM LENGTHS OF 6-10 INCHES ON AVERAGE. MULCH TO BE APPLIED AT THE RATE OF 2 TONS PER ACRE. UNIFORM COVERAGE REQUIRED. 8.ALL SLOPES GREATER THAN 3:1 TO RECEIVE FLEXTERRA HIGH PERFORMANCE-FLEXIBLE GROWTH MEDIUM (HP-FGM), APPLIED AS PER MANUFACTURER RECOMMENDATIONS - TYPICALLY 3,500 LBS/AC FROM 3:1 TO 2:1 SLOPE. CONFIRM WITH MANUFACTURER. 9.A PLANTAGO-BASED TACKIFIER OR SIMILAR (NONTOXIC AND FREE OF PLANT-GROWTH OR GERMINATION INHIBITORS) APPROVED PRODUCT SHALL BE APPLIED ON ALL MULCH AT THE RATE OF 150 LBS PER ACRE. 10.IMMEDIATELY FOLLOWING SEEDING OPERATIONS OF SPECIFIC ZONES, THE AREAS SHALL BE PROTECTED FROM TRAFFIC OR OTHER ACTIVITIES, EXCEPT WEED CONTROL. WATER NEWLY PLANTED AREAS AND KEEP MOIST UNTIL ESTABLISHED. 11.ALL SEED SHALL BE CERTIFIED WEED-FREE, FRESH, CLEAN, DRY, NEW CROP SEED COMPLYING WITH THE ASSOCIATION OF OFFICIAL SEED ANALYSIS "RULES FOR TESTING SEEDS" FOR PURITY AND GERMINATION TOLERANCES. NO SEED SHALL CONTAIN ANY SPECIES ON THE COUNTY OR STATE NOXIOUS WEED LIST. CONTRACTOR TO SUBMIT PURITY TAGS TO THE COUNTY VEGETATION MANAGER PRIOR TO INSTALLATION. 12.SEED SHALL BE PURE LIVE SEED EQUAL IN QUALITY TO THE STANDARDS FOR CERTIFIED BLUE TAG SEED. THE LANDSCAPE ARCHITECT, AT THE CONTRACTOR’S EXPENSE, MAY REQUIRE TESTS OF SEED VERIFICATION 13.SEED WILL BE FURNISHED IN SEALED, UNOPENED, STANDARD CONTAINERS AND LABELED IN CONFORMANCE WITH THE USDA RULES AND REGULATIONS AND THE FEDERAL SEED ACT. ALL MATERIAL SHALL BE STORED IN A MANNER THAT WILL PREVENT THEM FROM COMING INTO CONTACT WITH PRECIPITATION, SURFACE WATER OR OTHER CONTAMINATING SUBSTANCE. 14.NATIVE SEEDED AREAS SHALL BE ACCEPTED ON THE BASIS OF HAVING UNIFORM GRASS GROWTH OVER ALL THE SEEDED AREAS. ACCEPTABLE UNIFORM GRASS GROWTH SHALL BE DEFINED AS WHEN SCATTERED BARE SPOTS, NOT GREATER THAN ONE SQUARE FOOT, DO NOT EXCEED 5% OF THE SEEDED AREAS. 15.SOAK AND STRATIFY SEED OF WETLAND AND RIPARIAN SPECIES AS PER MANUFACTURER'S RECOMMENDATIONS. PLANTING SPECIFICATIONS 1.CONTRACTOR TO LOCATE UTILITIES PRIOR TO DIGGING AND FINAL TREE LOCATIONS TO BE ADJUSTED ACCORDINGLY. 2.PLANT TREES AND SHRUBS AFTER FINAL GRADES HAVE BEEN ACCEPTED AND PRIOR TO PLANTING TURF, UNLESS AUTHORIZED BY LANDSCAPE ARCHITECT. 3.LOCATIONS OF PLANTING ON PLAN ARE APPROXIMATE. CONTRACTOR TO FLAG ALL PROPOSED TREE AND WOODY SHRUB LOCATIONS FOR LANDSCAPE ARCHITECT REVIEW AND APPROVAL PRIOR TO INSTALLATION 4.ALL PLANT MATERIAL SHALL BE HEALTHY, SOUND AND FREE OF DISEASE. ALL PLANT MATERIAL TO BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. ALL PLANT MATERIAL TO COMPLY WITH STANDARDS DESCRIBED IN "AMERICAN STANDARD FOR NURSERY STOCK" (ANSI Z60.1-2014, OR LATEST EDITION). PROVIDE WELL-SHAPED, FULLY-BRANCHED, HEALTHY, VIGOROUS STOCK FREE OF WEEDS, DISEASE, INSECTS, EGGS, LARVAE, GIRDLING, AND DEFECTS SUCH AS SUN SCALD, INJURIES, ABRASIONS, AND DISFIGUREMENT. TREES AND SHRUBS OF A LARGER SIZE MAY BE USED IF ACCEPTABLE TO LANDSCAPE ARCHITECT WITH A PROPORTIONATE INCREASE IN SIZE OF ROOT BALLS. 5.ALL PLANTS SHALL BE THE SPECIES DESIGNATED ON THE DRAWINGS. NO SUBSTITUTIONS WILL BE ACCEPTED WITHOUT THE PRIOR WRITTEN APPROVAL OF THE LANDSCAPE ARCHITECT. CONTRACTOR MUST PROVIDE PROOF OF NON-AVAILABILITY. 6.MEASUREMENTS: MEASURE TREES AND SHRUBS ACCORDING TO ANSI Z60.1 WITH BRANCHES AND TRUNKS OR CANES IN THEIR NORMAL POSITION. DO NOT PRUNE TO OBTAIN REQUIRED SIZES. TAKE CALIPER MEASUREMENTS 6 INCHES ABOVE GROUND FOR TREES UP TO 4-INCH CALIPER SIZE, AND 12-INCHES ABOVE GROUND FOR LARGER SIZES. MEASURE MAIN BODY OF TREE OR SHRUB FOR HEIGHT AND SPREAD; DO NOT MEASURE BRANCHES OR ROOTS TIP-TO-TIP. 7.TREES AND SHRUBS: DELIVER NURSERY STOCKED OR FRESHLY DUG TREES AND SHRUBS. DO NOT PRUNE BEFORE DELIVERY, EXCEPT AS APPROVED BY LANDSCAPE ARCHITECT. PROTECT BARK, BRANCHES, AND ROOT SYSTEMS FROM SUN SCALD, DRYING, SWEATING, WHIPPING, AND OTHER HANDLING AND TYING DAMAGE. DO NOT BEND OR BIND-TIE TREES OR SHRUBS IN SUCH A MANNER AS TO DESTROY NATURAL SHAPE. PROVIDE PROTECTIVE COVERING DURING DELIVERY. PLANT MATERIALS DELIVERED WITHOUT PROTECTIVE COVERING MAY BE REJECTED. DO NOT DROP TREES AND SHRUBS DURING DELIVERY. LABEL AT LEAST ONE TREE AND ONE SHRUB OF EACH VARIETY PER DELIVERY WITH A SECURELY ATTACHED WATERPROOF TAG BEARING A LEGIBLE PLANT NAME. REMOVE ALL TAGS AND FLAGGING AS DIRECTED BY LANDSCAPE ARCHITECT. 8.TRANSPLANTED MATERIAL: LANDSCAPE ARCHITECT TO FLAG MATERIAL SUITABLE FOR TRANSPLANT AND DEMONSTRATE PROCESS ON SITE. YOUNG GREASEWOOD SHRUBS SHALL BE DUG AND TRANSPLANTED INTO #1 AND #2 CONTAINERS USING PRO-MIX POTTING SOIL TO FILL REMAINDER OF CONTAINER VOLUME. PLANTS SHALL BE IMMEDIATELY WATERED AND STORED IN A PROTECTED AREA OF THE SITE. VIABILITY OF MATERIAL TO BE ASSESSED IN SPRING BEFORE INSTALLATION IN THE LANDSCAPE. 8.1.DIGGING OF MATERIAL TO BE TRANSPLANTED SHOULD ONLY OCCUR WHILE PLANT MATERIAL IS DORMANT AND GROUND IS NOT FROZEN (SPRING AND FALL). 9.DRAINAGE: NOTIFY OWNER’S REPRESENTATIVE IF SUBSOIL CONDITIONS EVIDENCE WATER SEEPAGE OR RETENTION IN TREE OR SHRUB PITS. 9.1.FILL THE PIT WITH WATER AND ALLOW IT TO COMPLETELY DRAIN BEFORE PLANTING OCCURS. 9.2.IF WATER DOES NOT DRAIN OUT OF PIT WITHIN 24 HOURS, NOTIFY OWNER’S REPRESENTATIVE. 9.3.FOR TREE INSTALLATIONS TO BE COMPLETED IN THE SPRING, DIG TEST PITS PRIOR TO RECEIVING DELIVERY OF PLANT MATERIAL. IF PERCHED WATER IS ENCOUNTERED, PLANTING SCHEDULE MAY BE MODIFIED IN COORDINATION WITH OWNER’S REPRESENTATIVE AND LANDSCAPE ARCHITECT. 10.NOXIOUS VEGETATION SHALL BE CONTROLLED BY THE CONTRACTOR THROUGHOUT THE SEEDING ZONES AS WELL AS THE ENTIRE PROJECT SITE UNTIL FINAL ACCEPTANCE OR THROUGH THE MAINTENANCE PERIOD, WHICH EVER IS LONGER. 11.COMPOST TO BE INCORPORATED INTO PLANTING PITS FOR ALL TREE AND SHRUB PLANTINGS. SOURCE AND SAMPLE OF COMPOST TO BE APPROVED BY LANDSCAPE ARCHITECT BEFORE INSTALLATION. 12.MULCH TO BE REGIONALLY SOURCED AND A SAMPLE SUBMITTED TO THE LANDSCAPE ARCHITECT FOR APPROVAL. MULCH SHALL BE PLACED IN THE FOLLOWING AVERAGE THICKNESS AND FINISH LEVEL WITH ADJACENT FINISH GRADES. MULCH SHALL NOT BE PLACED AGAINST TRUNKS OR STEMS. 12.1.TREE RINGS: SHALL ACHIEVE MIN. 3' DIAMETER RING AT A 3-4" DEPTH OF MULCH (FOR TREE RINGS, MULCH WITH SPECIFIED DEPTH TO THE DRIPLINE). TREE GROUPINGS TO BE MULCHED CONTINUOUSLY. 12.2.MULCH BACKFILLED SURFACES OF PITS, PLANTED AREAS, NON-IRRIGATED ZONES, AND OTHER AREAS INDICATED. 13.WILDLIFE PROTECTION FENCING TO BE PROVIDED AROUND ALL TREES. FENCING TO BE EITHER AROUND INDIVIDUAL TREES OR WHEN APPROPRIATE AROUND CLUSTERS OF TREES. FINAL LAYOUT OF FENCING TO BE COORDINATED BETWEEN CONTRACTOR AND LANDSCAPE ARCHITECT. FENCING TO BE MAINTAINED THROUGHOUT THE WARRANTY PERIOD. TURFGRASS SOD SPECIFICATIONS 1.TURFGRASS TO BE LOCALLY SOURCED DROUGHT “SCOTTISH LINKS FINE FESCUE” FROM MAGIC VALLEY TURFGRASS, FILER, ID, OR APPROVED EQUAL. 2.TURF GRASS SOD: HARVEST, DELIVER, STORE, AND HANDLE SOD ACCORDING TO REQUIREMENTS IN "SPECIFICATIONS FOR TURFGRASS SOD MATERIALS" AND "SPECIFICATIONS FOR TURFGRASS SOD TRANSPLANTING AND INSTALLATION" IN TURFGRASS PRODUCTS INTERNATIONAL'S (TPI) "GUIDELINE SPECIFICATIONS TO TURFGRASS SODDING." DELIVER SOD IN TIME FOR PLANTING WITHIN 24 HOURS OF HARVESTING. PROTECT SOD FROM BREAKAGE AND DRYING. 3.INSTALL, IRRIGATE, AND MAINTAIN AS PER SUPPLIER'S RECOMMENDATION. 4.SODDED AREAS SHALL BE ACCEPTED ON THE BASIS OF HAVING A FULLY KNITTED MAT OF TURF, DEVOID OF VISIBLE JOINTS OR GAPS BETWEEN EACH SLAB AND DEVOID OF BARE PATCHES WITHIN ANY SLAB. TURF SURFACE SHALL BE CONSISTENT AND EVEN, WITHOUT BUMPS OR DIPS EXCEPT AS EXIST IN THE OVERALL CONTOUR OF GRADE AS DEFINED BY THE GRADING PLANS. WARRANTY INFORMATION 1.CONTRACTOR SHALL REPLACE ANY TREES, SHRUBS, OR ORNAMENTAL GRASSES THAT ARE DEAD, DAMAGED, UN-HEALTHY AND NOT GROWING VIGOROUSLY AT OWN EXPENSE UP TO ONE (1) YEAR FROM FINAL ACCEPTANCE. 2.ALL REPLACEMENT PLANTS WILL BE INSTALLED DURING AN APPROPRIATE PLANTING WINDOW CONSIDERING TEMPERATURE, WEATHER, SOIL, AND GENERAL SITE CONDITIONS. DATE ●ISSUE PERMIT SET DOCUMENT REUSE: TKLV GRFXPHQW LV WKH SURSHUW\ RI )LHOG SWXGLR LDQGVFDSH AUFKLWHFWV PLLC TKH LGHDV DQG GHVLJQ LQFRUSRUDWHG RQ WKLV GRFXPHQW VKDOO QRW EH XVHG IRU DQ\ RWKHU SURMHFW ZLWKRXW ZULWWHQ DXWKRUL]DWLRQ RI )LHOG SWXGLR LDQGVFDSH AUFKLWHFWV PLLC SHEET OF PROJECT NUMBER: SHEET TITLE  N R O U S E A 9 E  B O =E M A N  M T    Z Z Z I L H O G V W X G L R O D F R P MILL BUILDING RENOVATIONLOTS 5-28, BLOCK 105. BOZEMAN, MT2416.00 L-0.2 PLANTING NOTES 2 7 2025.02.07 SITE PL REVIEW 2025.03.17 SITE PL REV. 2025.04.09 SITE PL REV. 2