Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
205 L2.3 - IRRIGATION DETAILS
SHEET No:JOB No:DATE:LANDSCAPEARCHITECTURE614 S Ferguson Ave., Ste 3Bozeman, MT 59718(406)624-9111hello@inContour.comwww.inContour.comPREPARED FOR:inContour REV:DATE:DESCRIPTION:01/09/20251920 W. Babcock St., Bozeman, MT Babcock 5 Plex23210Firm 5Contact AddressBozeman, MT. 59718(206) 612-9372L2.3IRRIGATION DETAILS NOT FORCONSTRUCTIONRevIewSeT S TA T E OFMONTANALANDSCAPEARCH ITECTLICENSE D LESSA R.MILLARD2741" = 1'-0"REDUCED PRESSURE BACKFLOW DEVICEDEVICE AS SPECIFIED.AT EACH SIDE.GALVANIZED UNIONSGALVANIZED RISERS.REDUCED PRESSURE BACKFLOWGALVANIZED NIPPLESAND ELL AS REQUIRED.NIPPLE, TYPICAL EA. SIDE.MAIN LINE, SIZEAS PER PLANS.TYPICAL EACH SIDE.TOE NIPPLE,SCHEDULE 80 PVC COUPLER AND GALVANIZED ELL ANDCODE.HEIGHT ASPER LOCALSERVICESIDE.CONCRETE THRUST BLOCKS,90 LBS. OF CONCRETE EACH.FX-IR-FX-BACK-0311 1/2" = 1'-0"QUICK COUPLING VALVE IN BOXPVC MALE ADAPTER.GALVANIZED RISERAND ELBOW, QCINLET SIZE.MAIN LINE.60 LB. CONCRETE TORQUE1/2" WIRE CLOTH GOPHERSCREEN, WRAP UP SIDES.FOUR COMMON BRICKSAS SUPPORT UNDERBOX.BLOCK.10" DIAMETER VALVE BOX.FINISHED GRADE.QUICK COUPLER ASSPECIFIED.WITH 2" HIGH CHARACTERS.HEAD BRAND "QVC" ON LID10" DIAMETER VALVE BOX.FLUSH TO GRADE AT TURF.1" ABOVE GRADE AT SHRUBS.2" CLR FX-IR-FX-QUIC-0421 1/2" = 1'-0"MASTER CONTROL VALVEFX-IR-FX-MAST-583RPGV GLOBE VALVE WITH FLOW CONTROL1 1/2" = 1'-0"R18-24" COILED WIREWATERPROOF CONNECTORS (2)REMOTE CONTROL VALVEMODEL PGV-101GWITH FLOW CONTROLFINISH GRADESTANDARD VALVE BOXSCH 80 T.O.E. NIPPLEMAIN LINE PIPE & FITTINGSBRICK SUPPORTS (4)3/4" MINUS WASHED GRAVELSCH 80 T.O.E. NIPPLE4FX-IR-HUNT-VALV-03PROS-06 SPRAY HEAD WITH PRO-FLEX TUBING3" = 1'-0"RFINISH GRADEMODEL PROS-06 SPRAY HEADSWING JOINT:HUNTER 'PRO-FLEX' TUBING,HSBE-050 ELBOWS (2), &MARLEX STREET ELBOW (1)LATERAL TEE OR ELLLATERAL PIPE6FX-IR-HUNT-SPRA-327WALL MOUNTED CONTROLLER1/2" = 1'-0"Notes:1- Common and controller wire to be bundled using electrical tape at 10'-0" on center.2- Grounding rods shall be located between 8"- 0" to 12'- 0" away from the controller. Grounding rods shall be 38" in diameter x 8' in length. Connect the grounding rod to the controller using 6 gaugebare copper wire or per the manufacturer's specifications.See grounding rod detail.3- ET Station shall be installed no further than 90' away from the controller and a minimum of 15' off of the ground, out from under any overhead obstructions such as, but not limited to, buildingoverhangs, trees, or utilities.Wall, fence, or building.Wall mounted controller. Install permanufacturer's specifications andrecommendations. (See irrigation legendfor controller make and model number).34" knockout for earth ground wire.2" PVC electrical conduit for irrigationvalves, master valve, and flow sensor wires.Optional 3" knockout if more wires are needed.Secure conduit to wall using stainless steelclamp.1" PVC electrical conduit for electrical power perlocal and national electrical codes.1" PVC electrical conduit for ET sensor.(optional).SIDE VIEWSECTION VIEWFinished grade.18" Min.5'-0"URBAN TREE FOUNDATION © 2014OPEN SOURCE FREE TO USEIN-PR-BAB-20WIRELESS RAIN/FREEZE-CLIK3" = 1'-0"RNOTE:MOUNT SENSOR ON ANY SURFACE WHERE IT WILL BE EXPOSEDTO UNOBSTRUCTED RAINFALL, BUT NOT IN PATH OF SPRINKLER SPRAY, NO MORE THAN 1000'FROM RECEIVER UNIT. MOUNT UNIT NO FURTHER THAN 6' FROM CONTROLLER.WRC RECEIVERMODEL WRFCMOUNTING WALL8FX-IR-HUNT-SENS-18ICZ-101 DRIP CONTROL ZONE WITH UNIONS1 1/2" = 1'-0"R18-24" COILED WIREWATERPROOF CONNECTORS (2)DRIP ZONE KITMODEL ICZ-101-XX WITHFILTER (TIP 45 DEGREES)REGULATOR 25 OR 40 PSIFINISH GRADEJUMBO VALVE BOXSCH 80 T.O.E. NIPPLE (2)MAIN LINE PIPE & FITTINGSBRICK SUPPORTS (4)3/4" MINUS WASHED GRAVELPVC SLIP UNIONS (2)5FX-IR-HUNT-DRIP-17NOTES:1.SEE IRRIGATION LEGEND FOR MAINLINE SIZE AND TYPE.2.ALL SLEEVES SHALL BE SCH. 40 PVC PIPE.3.ALL SLEEVES SHALL EXTEND 12" BEYOND THE EDGE OF PAVEMENT.4.END OF SLEEVES SHALL BE LOCATED WITH A WOODEN STAKE OR PVC PIPE.LOCATORS SHALL RUN CONTINUOUSLY FROM THE END OF THE SLEEVE TO FINISHEDGRADE.PIPE BENEATH PAVEMENT1" = 1'-0"3'-0"PAVEMENT1BASE ROCK2CLEAN BACKFILL, 95%RELATIVE COMPACTIONUNDER PAVING OR PER CIVILENGINEER'S PLANS3CONTROL WIRES, SLEEVEUNDER PAVING.INSTALL ADJACENT TOPRESSURIZED MAINLINE.BUNDLE SHALL BE NO MORETHAN 50% OF PIPE DIAMETER4MAINLINE, SLEEVE UNDERPAVING TO BE TWO TIMESTHE DIAMETEROF THE PRESSURIZEDMAINLINE PIPE5NON-PRESSURIZED LINE,SLEEVE UNDER PAVING TOBE BE TWO TIMES THEDIAMETER OF THE LATERALLINE6234569IN-PR-BAB-80THRUST BLOCKING3/4" = 1'-0"45 DEG. ELBOWTEE90 DEG. ELBOWEND OF LINECAPPED LINE1UTILITY BOX1122POURED IN-PLACE CONCRETE, 120 LBS. MINIMUM, TYPICAL1FINISHED GRADE210IN-PR-BAB-81IRRIGATION TRENCHING1 1/2" = 1'-0"12NOTES:1.SEE IRRIGATION LEGEND FOR MAINLINE AND LATERALLINE PIPE SIZE AND TYPE.2.DIRECT BURIAL CONTROL WIRES SHALL BE INSTALLEDIN SCH. 40 PVC ELECTRICAL CONDUIT IF REQUIRED.3.2-WIRE IRRIGATION WIRE SHALL BE INSTALLED IN SCH.40 PVC ELECTRICAL CONDUIT.4.DETECTABLE LOCATOR TAPE SHALL BE LOCATED SIXINCHES (6") ABOVE THE ENTIRE MAINLINE RUN.24" MIN.6" 1'-0" IN PLANTING AREA FINISHED GRADE1PAVEMENT2NON-PRESSURIZED LINE(LATERAL LINE)3DETECTABLE LOCATOR TAPE4PRESSURIZED LINE (MAINLINE)5DIRECT BURIAL LOW VOLTAGE CONTROLWIRES634561'-6" IN PLANTING AREA 3'0" UNDERNEATH PAVEMENT11 IN-PR-BAB-82SLEEVE AT ROAD1 1/2" = 1'-0"FINISHED GRADENATIVE SOIL BACKFILLCOMPACT TO 95% COMPACTIONPVC MAIN LINEBACKFILL WITH 100% COARSE SAND, WATER JET &MECHANICALLY COMPACT TO 90% OPTIMUMDENSITY. ALLOW 48 HOURS TO SETTLE, ANDBACKFILL AND COMPACT WITH NATIVE SOIL.4" MIN. BEDDING 4" MIN.4" MIN.4" MIN. DEPTH AS PER SPEC.WIDTH VARIES12IN-PR-BAB-83