HomeMy WebLinkAbout204 L2.2 - IRRIGATION SCHEDULE & NOTESIRRIGATION NOTES1.CONTRACTOR RESPONSIBLE FOR SCHEDULING PRE-INSTALLATION MEETING WITH CITY OF BOZEMANWATER CONSERVATION DIVISION PRIOR TO COMMENCING ANY WORK.2.LANDSCAPE & IRRIGATION SELF-CERTIFICATION FORMS REQUIRED TO RECEIVE CITY OF BOZEMANBUILDING PERMIT.3.CONTRACTOR RESPONSIBLE FOR PROVIDING IRRIGATION AS-BUILTS TO OWNER AT COMPLETION OFINSTALLATION.4.CONTRACTOR RESPONSIBLE TO INFORM LANDSCAPE ARCHITECT OF ANY DISCREPANCIES OR CHANGESNEEDED TO THE IRRIGATION DESIGN. IF CONTRACTOR MAKES CHANGES TO THE IRRIGATION DESIGNWITHOUT NOTIFYING THE LANDSCAPE ARCHITECT, CONTRACTOR ASSUMES FULL RESPONSIBILITY OF THEIRRIGATION SYSTEM DESIGN AND FUNCTIONALITY.5.CONTRACTOR TO VERIFY STATIC PRESSURE IN THE FIELD PRIOR TO BIDDING AND CONSTRUCTION. IN THEEVENT OF A DISCREPANCY, CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT IN WRITING OF ANYCHANGES NECESSARY TO PROVIDE THE REQUIRED OPERATIONAL PRESSURE AND FLOW. IF NOTIFICATIONIS NOT RECEIVED, CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR SYSTEM OPERABILITY.6.PROVIDE PRESSURE REDUCING VALVE IF PRESSURE EXCEEDS 80 PSI. REDUCE TO 60PSI STATICPRESSURE.7.INSTALLED SYSTEM TO BE FULLY WINTERIZEABLE. CONTRACTOR TO PROVIDE LANDSCAPE ARCHITECTWITH WINTERIZATION PLAN.8.CONTRACTOR SHALL COORDINATE PLANTING WITH IRRIGATION INSTALLATION.9.THE CONTRACTOR SHALL INSPECT THE SITE AND VERIFY CONDITIONS AND DIMENSIONS PRIOR TOCONSTRUCTION.10.IRRIGATION PLANS ARE SCHEMATIC REPRESENTATIONS ONLY. PLACE LINES IN A COMMON TRENCHWHENEVER POSSIBLE. FIELD ADJUST LINES TO AVOID CONFLICT WITH UTILITIES.11.IRRIGATION IS COORDINATED WITH THE PLANTING PLAN AND SITE IMPROVEMENTS AND IS DESIGNED WITHRECTANGULAR SPACING GIVING HEAD TO HEAD COVERAGE. COORDINATE IRRIGATION HEAD LAYOUTWITH NEW PLANT MATERIALS, LOCATE SPRAY HEADS 30" FROM BASE OF TREE. DO NOT ALTER HEADLOCATION, PIPE LAYOUT, OR VALVE LOCATION WITHOUT WRITTEN APPROVAL FROM THE CONSTRUCTIONMANAGER. NOTIFY LANDSCAPE ARCHITECT IF DISCREPANCIES OCCUR BETWEEN THE PLANS AND FIELDCONDITIONS.12.ALL COMPONENTS OF IRRIGATION SYSTEM SHALL BE INSTALLED AND PROPERLY ADJUSTED TO PROVIDEADEQUATE HEAD TO HEAD COVERAGE AND MINIMIZATION OF OVER SPRAY ONTO WALKS, BUILDINGS,PARKING AREAS, ETC.13.ALL PIPE SIZES INDICATED ARE MINIMUMS. CONTRACTOR MAY NOT DECREASE PIPE SIZE. LARGER PIPESIZES MAY BE USED AT NO ADDITIONAL COST TO OWNER. PIPE SIZES INCREASE IN SIZE DOWNSTREAM OFNEXT SPRAY HEAD, AS SHOWN.15.ALL PVC PIPES SHALL BE TRENCHED. POLLY PIPE MAY BE PULLED. PROVIDE POSITIVE DRAINAGE OFMAINLINE. PLACE MANUAL DRAIN AT LOW POINTS IN MAINLINE. IDENTIFY LOCATIONS ON AS-BUILTS.16.COORDINATE IRRIGATION POINTS OF CONNECTION AND LOCATION OF AUTOMATIC CONTROL VALVES WITHPROJECT MANAGER. COORDINATE ALL WORK WITH OTHER TRADES, I.E. ELECTRICAL, MASONRY, ETC.17.CONTRACTOR TO PROGRAM AUTOMATIC CONTROLLER TO ALLOW FOR THE EQUIVALENT OF 1" OF WATERPER WEEK, OR PER SITE AND PLANTING NEEDS FOR BEST PLANT HEALTH.18.ALL PIPES SHALL BE TRENCHED. PROVIDE POSITIVE DRAINAGE OF MAINLINE. PLACE MANUAL DRAIN ATLOW POINTS IN MAINLINE. IDENTIFY LOCATIONS ON AS-BUILTS.19.USE 45°. ELLS INSTEAD OF 90-DEG. ELLS ON ALL MAINLINES 2-1/2" AND LARGER. INSTALL CMU THRUSTBLOCKS AT ALL MAINLINE CHANGES IN DIRECTION.20.CONTRACTOR TO INSTALL CONTROLLER AND ACCESSORIES AS REQUIRED. CONTRACTOR TO FURNISHCONTROL WIRES FROM VALVES TO CONTROLLER. CONTRACTOR SHALL BE RESPONSIBLE FORCOORDINATING 110 VOLT SERVICE FROM EXISTING ELECTRICAL SERVICE AND CONNECTION TOCONTROLLER SERVICE.21.INSTALL ONE (1) ADDITIONAL RED CONTROL WIRE AND ONE (1) ADDITIONAL WHITE CONTROL WIRE FROMCONTROLLER TO END OF MAINLINE.ESTIMATED WATER CONSUMPTIONWATER CONSUMPTION ESTIMATES ARE BASED ON A SEASONAL24-WEEK WATERING WINDOW, AND ARE LISTED IN ANNUAL TOTALSACRE FEET BASED ON SYSTEM DESIGN2,239 GAL/.WEEK = 0.16 AC.FT.ACRE FEET BASED ON VEGETATION TYPE SQUARE FEETTURF: 1,472 S.F. = 0.07 AC.FT.SHRUBS & GROUND COVER: 3,087 S.F. = 0.14 AC.FT.TREES: 24 S.F. = 0.01 AC.FT.TEMPORARY NATIVE GRASS ESTABLISHMENT: 1,082 S.F. = 0.05 AC.FT.SYMBOLMANUFACTURER/MODEL/DESCRIPTIONQTYPSIHUNTER MP1000 PROS-06-PRS40-CVTURF ROTATOR, 6" POP-UP WITH CHECK VALVE, PRESSUREREGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY.M=MAROON ADJ ARC 90 TO 210, L=LIGHT BLUE 210 TO 270 ARC,O=OLIVE 360 ARC.1640TEMPORARY ESTABLISHMENT IRRIGATIONZONE TO BE ABANDONED AFTER ESTABLISHMENT PERIOD.HUNTER MP STRIP PROS-06-PRS40-CV. TURF ROTATOR, 6" POP-UPWITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY. LST=IVORY LEFT STRIP,SST=BROWN SIDE STRIP, RST=COPPER RIGHT STRIP.3240SYMBOLMANUFACTURER/MODEL/DESCRIPTIONQTYHUNTER ICZ-101-25-LF 1"DRIP CONTROL ZONE KIT. 1" ICV GLOBE VALVE WITH 1" HY100 FILTERSYSTEM. PRESSURE REGULATION: 25PSI. FLOW RANGE: .5-15 GPM.150 MESH STAINLESS STEEL SCREEN.3HUNTER HDL-06-12-R DRIP RING6AREA TO RECEIVE DRIP EMITTERSHUNTER HE-BPOINT SOURCE DRIP EMITTER WITH SELF PIERCING BARB. COLORCODED EMITTERS FOR FLOW RATES OF 0.5, 1.0, 2.0, 4.0, AND 6.0 GPH.CAN BE INSERTED INTO 1/2" AND 3/4" TUBING AND HAVE PRESSURECOMPENSATING FROM 15-50 PSI. OPTIONAL DIFFUSER CAP (HE)AVAILABLE.3,087 S.F.Emitter Notes:05HE-B emitters (2 assigned to each 1 gal. plant)05HE-B emitters (2 assigned to each 2 gal. plant)05HE-B emitters (2 assigned to each 4" plant)10HE-B emitters (2 assigned to each 1.75" Cal. plant)10HE-B emitters (2 assigned to each 5 gal. plant)20HE-B emitters (2 assigned to each 2" Cal. plant)20HE-B emitters (2 assigned to each 8` Ht. plant)20HE-B emitters (2 assigned to each 15 gal. plant)SYMBOLMANUFACTURER/MODEL/DESCRIPTIONQTYHUNTER PGV-101G 1"1" PLASTIC ELECTRIC REMOTE CONTROL VALVE, FORRESIDENTIAL/LIGHT COMMERCIAL USE. FEMALE NPT INLET/OUTLET.GLOBE CONFIGURATION, WITH FLOW CONTROL.2HUNTER HQ-33DRC 3/4"QUICK COUPLER VALVE, YELLOW RUBBER COVER, RED BRASS ANDSTAINLESS STEEL, WITH 3/4" NPT INLET, 2-PIECE BODY.1LASCO FITTINGS TUBV-SC1", 1-1/2", 2", AND 3" PLASTIC FULL BLOCK TRUE UNION BALL VALVE.SHUT OFF/ISOLATION VALVE TO ELIMINATE WATER HAMMER. INSTALLSAME SIZE AS MAINLINE.1BUCKNER-SUPERIOR 3000 1"NORMALLY CLOSED BRASS MASTER VALVE THAT PROVIDES DIRTYWATER PROTECTION AND 3-WAY SOLENOID DESIGN. AVAILABLE IN 1",1-1/4", 1-1/2", 2", 2-1/2" AND 3" SIZES.1FEBCO LF825Y 1"REDUCED PRESSURE BACKFLOW PREVENTER, LEAD FREE1HUNTER HC-66 STATION CONTROLLER WITH WI-FI CONNECTION1HUNTER WRF-CLIKRAIN/FREEZE SENSOR, INSTALL WITHIN 1000 FT OF CONTROLLER, INLINE OF SIGHT. 22-28 VAC/VDC 100 MA POWER FROM TIMERTRANSFORMER. MOUNT AS NOTED. INCLUDES GUTTER MOUNT.1POINT OF CONNECTION 1"DOMESTIC SERVICE LINE1IRRIGATION LATERAL LINE: POLYETHYLENE PIPE SDR-7 1"1,267 L.F.IRRIGATION LATERAL LINE: POLYETHYLENE PIPE SDR-7 1 1/4"0.1 L.F.IRRIGATION MAINLINE: PVC SCHEDULE 40 1"373.5 L.F.PIPE SLEEVE: PVC SCHEDULE 4043.4 L.F.MLOLSTRSTSSTMBFCRFPOCValve NumberValve FlowValve SizeValve Callout###"IRRIGATION SCHEDULECRITICAL ANALYSISNUMBERMODELTYPEPRECIPSUNMONTUEWEDTHUFRISATIN./WEEKMIN./WEEKGAL./WEEKGAL./DAY1HUNTER PGV-101GTURF ROTARY0.55 in/h28 min28 min28 min0.75825771922HUNTER ICZ-101-25-LFAREA FOR DRIP EMITTERS0.2 in/h102 min102 min102 min13045611873HUNTER ICZ-101-25-LFDRIP RING0.57 in/h36 min36 min36 min110689.029.74HUNTER PGV-101GTURF ROTARY0.35 in/h44 min44 min44 min0.751307062355HUNTER ICZ-101-25-LFAREA FOR DRIP EMITTERS0.35 in/h58 min58 min58 min1174307102TOTALS:2682682687962,239746.5WATERING SCHEDULEFLOW TOTALSArea for Drip Emitters:3.6Drip Ring:0.8Turf Rotary:12.5Total:16.9 GPMFLOW AVAILABLE18.2 GPMArea for Drip Emitters:1 ValvesDrip Ring:1 ValvesTurf Rotary:1 ValvesTotal:3 ValvesGenerated:2025-01-02 16:23P.O.C. NUMBER: 01Water Source Information:DOMESTIC SERVICE LINEFLOW AVAILABLEPoint of Connection Size:1"Flow Available18.2 GPMPRESSURE AVAILABLEStatic Pressure at POC:65 PSIPressure Available:65 PSIDESIGN ANALYSISMaximum Station Flow:7.04 GPMFlow Available at POC:18.2 GPMResidual Flow Available:11.16 GPMCritical Station:1 Design Pressure:40 PSI Friction Loss:0.67 PSI Fittings Loss:0.07 PSI Elevation Loss:0 PSI Loss through Valve:1.9 PSIPressure Req. at Critical Station:42.6 PSILoss for Fittings:0.06 PSILoss for Main Line:0.63 PSILoss for POC to Valve Elevation:0 PSILoss for Backflow:12.0 PSILoss for Master Valve:0.44 PSICritical Station Pressure at POC:55.8 PSIPressure Available:65 PSIResidual Pressure Available:9.18 PSIPERFORMANCE LANDSCAPE DESIGN PATHWAYSHEET No:JOB No:DATE:LANDSCAPEARCHITECTURE614 S Ferguson Ave., Ste 3Bozeman, MT 59718(406)624-9111hello@inContour.comwww.inContour.comPREPARED FOR:inContour
REV:DATE:DESCRIPTION:01/09/20251920 W. Babcock St., Bozeman, MT
Babcock 5 Plex23210Firm 5Contact AddressBozeman, MT. 59718(206) 612-9372L2.2IRRIGATION SCHEDULE & NOTES
NOT FORCONSTRUCTIONRevIewSeT S TA
T
E
OFMONTANALANDSCAPEARCH
ITECTLICENSE
D LESSA R.MILLARD274