Loading...
HomeMy WebLinkAbout006 A2.00 - MAIN FLOOR PLAN1 A4.00 9' - 6"26' - 6"32' - 0"26' - 6"9' - 6" 26' - 0"7' - 0"9' - 0"20' - 0"9' - 0"7' - 0"26' - 0"7' - 0"3' - 6"9' - 0"3' - 6"38' - 0"2' - 0"11' - 6"5' - 9"5' - 9"3' - 0"12' - 0"13' - 6"5' - 6"7' - 0"6' - 8"13' - 4"7' - 0"5' - 6"13' - 6" 4' - 0"2' - 8"19' - 10"8' - 10"2' - 6"5' - 8"6' - 0"9' - 0"3' - 0"12' - 6"4' - 0 1/2"2' - 8"4' - 3 1/2"38' - 0"2' - 0"11' - 6"5' - 9"5' - 9"3' - 0"12' - 0"2 A4.01 1 A4.01 E1 BED E1 BATH BATH E2 BED BED BATH C1 BATHMECH/LAUNDRYMECH A2 BED BATH A1 BATH MECH PANTRY PANTRY A1 BED C1 BED ENTRY DINING KITCHEN LIVING DINING LIVING KITCHEN ENTRY ENTRY DINING KITCHEN LIVING APPROX LOCATION OF METERS 6' - 0"4' - 8" 3' - 6" 6' - 8"3' - 7" 3' - 6" 4' - 10" 6' - 0" 4' - 6"4' - 4"12' - 6"3' - 0"5' - 4"4' - 6" D1 A A D13 D8D7D7D7 D5 D7 D8 D10 D10D6 D6B A B D4 D7 D7D7 D7D6 D4 D1 C D1 A D10 D10 D6D7 D7 D7 D7D8 AD23' - 6"3' - 4"D8 2' - 8"3' - 0"D6D1 8' - 8"4' - 0 1/2"2' - 5 1/2"4' - 0 1/2"4' - 2"4' - 6"E.P. FURN. E.P. E.P. FURN. FURN.2' - 8"6' - 4"D56' - 10"5' - 3"5' - 2"4' - 2"5' - 4"10' - 9"6' - 5"3' - 4" 6' - 0"3' - 0"2' - 8"6' - 3 1/2" 5' - 6"4' - 5 1/2"6' - 5"10' - 9"5' - 2"5' - 3"6' - 10"3' - 0"0' - 6"7' - 0" 1 1 AA BB CC DD GG HH 2 3 4 4 5 6 8 9 10 10 11 13 13 EE FF W2 W2 W2W3W3 W2 W2 WE2 WE1 WE2 WE2 WE1 WE2 WE1 WE2 WE1 WE2 WE1 W2 W2 W2 W2 W2 W2 W2 W2 W2 WE1 W2 W2 W2 W2 WE1 WE1 WE1 WE1 W2 W2 W2 W3 W3 W2 W2 W2 W2 W2 W2 W2 W2 W2 WE1 WE1 WE2WE2 W3 W2 W2 W2 W1W1 3 A4.12 4 A5.00 1250 SF (INCL. EXT. WALLS) UNIT A 1160 SF (INCL. EXT. WALLS) UNIT C 1250 SF (INCL. EXT. WALLS) UNIT E 3 A4.01 A2.10 1 A2.10 2 A2.10 3 104' - 0"BENCH/HOOKSBENCH/HOOKSBENCH CONCRETE WALL PER STRUCTURAL A2.10 4 A2.10 5 12 W3 3' - 6"3' - 6"2' - 6"9' - 0"3' - 6"3' - 6"9' - 0"2' - 6"VERT. COLUMN PER STRUCTURAL 1 A5.02 7' - 0"4 A4.00 3 A5.01 4 A5.01 8' - 8"8' - 8"3' - 10"4' - 11"3' - 10"4' - 11"4 A4.01 7 D84' - 0"7' - 6"E 4' - 0"3' - 6"3' - 0"9' - 0"WE2 WE2 3' - 0"9' - 0"4' - 0"F F F F F F F F E C 2 A4.11 RECESSED MECH ROOM WATER LINE & GENERAL MECH SERVICES FLOOR PLAN GENERAL NOTES 1. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 2. ALL WORK SHALL COMPLY WITH APPLICABLE CODES LISTED. 3. ALL MATERIALS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS UNLESS NOTED OTHERWISE. DRAWINGS SHOW THE DESIGN INTENT AND MAY NOT SHOW ALL DETAILS FOR INSTALLATION. 4. ALL ELECTRICAL AND PLUMBING WORK SHALL BE INSTALLED BY LICENSED PROFESSIONAL(S) AND SHALL CONFORM WITH CURRENT CODES. 5. CONFIRM AND COORDINATE LOCATIONS OF ALL UTILITIES WITH CONTRACTOR. 6. FIELD VERIFY ALL DIMENSIONS. DO NOT SCALE DRAWINGS. 7. ALL DIMENSIONS ARE FROM STRUCTURAL GRIDLINES OR UNFINISHED FACE OF STUD, UNLESS OTHERWISE NOTED. 8. GENERAL CONTRACTOR SHALL COORDINATE ALL ASPECTS OF THE BUILDING CONSTRUCTION. 9. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH AND REPAIR ALL INCONSISTENCIES IN FLOOR ELEVATIONS. 10. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED TO PROVIDE SUITABLE SUBSTRATE FOR FINISHES. 11. THE MEANS AND METHODS OF CONSTRUCTION IS THE RESPONSIBILITY OF THE CONTRACTOR. 12. PROVIDE BLOCKING AS NEEDED FOR ALL WALL MOUNTED EQUIPMENT, FURNISHINGS, ETC. 13. PROTECTION OF PENETRATIONS OF WALL OR FLOOR/CEILING ASSEMBLIES REQUIRED TO BE FIRE-RESISTANCE RATED IN ACCORDANCE WITH SECTION R302.2 OR R302.3. 14. THE FLAME SPREAD FOR WALLS AND CEILINGS FINISHED TO BE NOT GREATER THAN 200 (R302.9.1) 15. THE SMOKE-DEVELOPED INDEX FOR WALLS AND CEILINGS SHALL NOT HAVE AN INDEX GREATER THAN 450 (R302.9.2) 16. FIREBLOCKING VERTICALLY AT FLOOR AND CEILINGS, HORIZONTALLY AT INTERVALS NO GREATER THAN 10. CONCEALED SPACES (SOFFIT, DROP CEILINGS, MECH CHASES, ETC) BETWEEN VERTICAL AND HORIZONTAL SPACES SHALL HAVE FIREBLOCKING. 17. SMOKE DETECTORS AND CARBON MONOXIDE ALARMS SHALL BE INSTALLED IN EXISTING BEDROOMS AND HALLWAYS PER IRC 314 & 315. 18. CONTINUITY OF FIRE-RESISTANCE-RATING SHALL BE CONTINUOUS FROM FOUNDATION TO UNDERSIDE OF ROOF DECKING. SHALL EXTEND THE FULL LENGTH OF THE WALL OR ASSEMBLY, INCLUDING EXTENSIONS. 19. ALL EGRESS WINDOWS FROM BEDROOMS SHALL HAVE A NEW CLEAR OPENING 5.7 SF AND A MAXIMUM SILL HEIGHT OF 42" SCALE: DRAWN: PROJECT NO: DATE: As indicated 3/17/2025 1:40:45 PM A2.00 22-013 MAIN FLOOR PLAN Babcock 5 Plex Maloney Holdings, LLC 1920 W Babcock Street, Bozeman MT 1/4" = 1'-0"1 First Floor Plan NOT FOR CONSTRUCTION