058 - E1.1.3 - ELEC. DETAILS & SCHEDULE
SECTION VIEW PLAN VIEW 2'-0" DIA 1'-0" 3'-0" TO CURB OR CENTER IN ISLAND 3"2'-0"REFER TO SECTION BELOW CONTRACTOR SHALL USE TEMPLATE FURNISHED WITH POLE TO SET ANCHOR BOLTS. CENTER POLE ON CONCRETE BASE. CONNECT TO GROUND LUG ON POLE ANCHOR BOLTS FOR POLE AS REQUIRED BY POLE MANUFACTURER 5/8" CHAMFER EXOTHERMIC WELD OR HYDRAULIC COMPRESSION CONNECTION 6" LOOP #6 BARE STRANDED COPPER BONDING CONDUCTOR IN 1/2" MIN. PVC OR ENT SLEEVE. MINIMUM 8" RADIUS. 5/8"Ø x 10'-0" COPPER CLAD GROUND ROD TRANSITION TO RIGID METAL CONDUIT FOR RISER INSULATED BUSHING TERMINATION ANCHOR BOLT COVER NON-SHRINK GROUT BETWEEN POLE AND BASE. PROVIDE A CHANNEL THROUGH THE GROUT FOR POLE INTERIOR DRAINAGE. EXPOSED SURFACES TOWELED SMOOTH 2 3/4" OR AS REQUIRED BY POLE MANUFACTURERFINISHED GRADE NON-FROST SUSCEPTIBLE FILL PER GEOTECH 4'-0" SQ x 12" DP FTG W/ (5) #4 EA WAY. 3" CLR AT BOTTOM IMEG RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG AND SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG. ©2024 IMEG CONSULTANTS CORP. REF. SCALE IN INCHES 0 1 2 3 N E C PROJECT DRAWING PROJ. NO. SHEET GENERAL NOTES ISSUANCES DATE B A 1 E D C B A PROJECT TEAM © 2023 COPYRIGHT G|R|E|C ARCHITECTS BUILDING DEPT STAMP D SEAL 1. THIS DOCUMENT WITH THE ACCOMPANYING DRAWINGS, SPECIFICATIONS AND/OR PROJECT MANUAL, DESCRIBES THE GENERAL SCOPE OF THE PROJECT AND DESIGN CONCEPT AND DESIGN CONCEPT IN TERMS OF THE INTERIOR DESIGN, ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS. THESE DOCUMENTS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL OF THE WORK REQUIRED FOR THE FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE SCOPE INDICATED, DESCRIBED OR INFERRED, THE CONTRACTOR SHALL DETERMINE AND INCLUDE IN THE PROPOSALS ALL ITEMS NECESSARY TO PROVIDE PROPER EXECUTION AND COMPLETION OF THE WORK. 2. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONFIRM ANY EXISTING SITE CONDITIONS, AND SHALL NOTIFY THE ARCHITECT OF ANY DIMENSIONAL DISCREPANCIES PRIOR TO BEGINNING WORK. GR E CArchitects| | | OWNE 2345678 12345678 PROJECT #23008933.00 10/31/2024 5:31:09 PM Autodesk Docs://2215 - Bozeman MT/MEPT24_22008933.00_GREC-Bozeman-MT-Hotel Bozeman_C.rvtHOTEL BOZEMAN 205 N TRACY AVE. BOZEMAN, MT E1.1.3 ELEC. DETAILS & SCHEDULE 2215 ARCHITECT G|R|E|C ARCHITECTS, LLC INTERIOR DESIGN G|R|E|C ARCHITECTS, LLC STRUCTURAL ENGINEER D'AMATO CONVERSANO INC. MEPFP ENGINEER IMEG CORP. CIVIL ENGINEER STAHLY ENGINEERING & ASSOCIATES LANDSCAPE ARCHITECT DESIGN.5 LANDSCAPE ARCHITECTURE HOTEL BOZEMAN INVESTORS, LLC EXTERIOR CORRELATED COLOR TEMPERATURE 3000K, COLOR RENDERING INDEX (CRI) AT OR ABOVE 80, UNLESS NOTED OTHERWISE. FINAL COLOR SELECTION OF ALL FIXTURES BY ARCHITECT FOR ALL FIXTURES AND POLES CATALOG NUMBER SHALL NOT BE CONSIDERED COMPLETE AND MATERIAL SHALL NOT BE ORDERED BY MANUFACTURER AND CATALOG NUMBER ONLY. THE COMPLETE DESCRIPTION AND THE SPECIFICATION SHALL BE COORDINATED WITH THE CATALOG NUMBER TO DETERMINE THE EXACT MATERIAL AND ACCESSORIES TO BE ORDERED. THE FIRST MANUFACTURER LISTED IS THE BASIS OF DESIGN. VERIFY AND COORDINATE ALL CEILING TYPES WITH LUMINAIRE MOUNTING AND TRIM REQUIREMENTS PRIOR TO THE RELEASE OF THE LUMINAIRE ORDER. CONFIRM ALL COLORS AND FINISHES OF ALL LUMINAIRE COMPONENTS WITH ARCHITECT AND INTERIOR DESIGNER PRIOR TO THE RELEASE OF THE LUMINAIRE ORDER. UNLESS INDICATED ON LIGHTING PLANS OR BELOW, REFER TO ARCHITECTURAL AND INTERIOR DESIGN ELEVATIONS, SECTIONS AND DETAILS FOR ALL SUSPENDED AND WALL MOUNTED LUMINAIRE MOUNTING HEIGHTS. DMX - DIGITAL MULTIPLEX EM - EMERGENCY BATTERY ML - MULTI-LEVEL SWITCHING O - OTHER (SEE DESCRIPTION) DALI - DIGITAL ADDRESSABLE ELV - ELECTRONIC LOW VOLTAGE LINE - LINE VOLTAGE DIMMING REM - REMOTE 0-10V - 0-10V DIMMING EB - ELECTRONIC HL - HIGH/LOW (100%/50%) STEP DIM MV - MULTI-VOLTAGE ELECTRONIC (TYPE) DRIVER: PL - POLE O - OTHER (SEE DESCRIPTION)DLED - DYNAMIC TUNABLE LED WLED - WARM DIM LED P - PERIMETER WL - WALL OLED - ORGANIC LED RLED - RETROFIT LED FR - FLANGED RECESSED UC - UNDER CABINET TLED - TUBULAR LED LAMP RGBA - COLOR CHANGING + AMBER CV - COVE SU - SURFACE LED - LIGHT EMITTING DIODE RGBW - COLOR CHANGING + WHITE CL - CEILING SURFACE SP - SUSPENDED (TYPE) LED RGB - COLOR CHANGING LED (MTG) MOUNTING:RE - RECESSED (WATT) PER: FIX - FIXTURE, FT - FOOT, LAMP CFSA - COLOR-FINISH SELECTION BY ARCHITECT [DESIGN SPECIFIC BLANKS] PAF - PAINT AFTER FABRICATION WW - WALL WASH K - KSH12 .125" ACRYLIC O - OTHER (SEE DESCRIPTION) FINISH:VWD - VERY WIDE G - TEMPERED GLASS SS - SEMI-SPECULAR CLEAR RS - REGRESSED STEEL V - ANSI/IES TYPE 5 DISTRIBUTION WD - WIDE F - FROSTED ACRYLIC R - HIGH IMPACT DR ACRYLIC RA - REGRESSED ALUMINUM IV - ANSI/IES TYPE 4 DISTRIBUTION MD - MEDIUM C - CLEAR ALZAK P - POLYCARBONATE FS - FLAT STEEL III - ANSI/IES TYPE 3 DISTRIBUTION SP - SPOT B - BAFFLE/LOUVER N - NONE FA - FLAT ALUMINUM II - ANSI/IES TYPE 2 DISTRIBUTION NSP - VERY NARROW SPOT A - .125" ACRYLIC M - MATTE DIFFUSE CLEAR (DESC) DOOR: DISTRIBUTION: BEAMWIDTH: (L/L) LENS/LOUVER:K19 - KSH19 .156" ACRYLIC LED LUMINAIRE SCHEDULE ITEM DESCRIPTION L/L MTG DIMENSIONS WATT LED DRIVER MANUFACTURER AND MODELL W H DIA. ANSI WATTS PER TYPE QTY DELIVERED LUMENS (MIN)VOLTS TYPE P1 EXTERIOR POLE LUMINAIRE. T5 WIDE DISTRIBUTION. UL LISTED FOR WET LOCATIONS. MARINE GRADE FINISH. LUMINAIRE MOUNTED AT 12' ON A 14' POLE O PL 0" 0" 12'-0" 0" 47 W FIX LED 1 3796 277 V 0-10V POLE LIGHT FIXTURE : ANP LIGHTING POLE MOUNT FIXTURE : STRUCTURA BEAM POLE S1 CYLINDRICAL WALLWASH SCONCE WITH PURE ANODIZED ALUMINUM REFECTOR SURFACE AND STAINLESS STEEL MOUNTING PLATE, NARROW BEAM LIGHT DISTRIBUTION. MARINE GRADE FINISH. AND SUITABLE FOR WET LOCATIONS. PROVIDE WITH 0-10V DIMMING OPTION COMPATIBLE WITH THE LIGHTING CONTROL SYSTEM O WL 1'-0" 6" 11 W FIX LED 1 652 277 V 0-10V WALL LUMINAIRE BY BEGA 24 515 S1E SAME AS S1 BUT CONNECTED TO EMERGENCY POWER. O WL 1'-0" 6" 18 W FIX LED 1 652 277 V 0-10V WALL LUMINAIRE BY BEGA 24 515 S2 EXTERIOR WALL SCONCE LUMINAIRE. WITH HIGH GRADE SPUN ALUMINUM REFLECTOR AND ALUMINUM MOUNTING ARM WITH STAINLESS STEEL MOUNTING HARDWARE. FLEXIBLE LOCALIZED DISTRIBUTION, AND LISTED FOR WET LOCATIONS. O WL 1'-0" 6" 11 W FIX LED 1 754 277 V 0-10V MELLO WALL TMSLIGHTING S2E SAME AS S2 EXCEPT CONNECTED TO EMERGENCY POWER O WL 1'-0" 6" 15 W FIX LED 1 754 277 V 0-10V MELLO WALL TMSLIGHTING S3 SQUARE RECESSED LOW PROFILE DOWNLIGHT LUMINAIRE WITH WIDE BEAM LIGHT DISTRIBUTION, MARINE GRADE FINISH, AND SUITABLE FOR WET LOCATIONS. CL RE 4" 4" 0" 15 W FIX LED 1 1500 277 V 0-10V EVO SQUARE DOWN LIGHT BY GOTHAM S3E SAME AS S3 EXCEPT CONNECTED TO EMERGENCY POWER. CL RE 4" 4" 0" 15 W FIX LED 1 1500 277 V 0-10V EVO SQUARE DOWN LIGHT BY GOTHAM S4 RECTANGULAR WALL PACK LUMINAIRE WITH POLYMER REFRACTOR LENS, TYPE 2 DISTRIBUTION, DIE CAST ALUMINUM HOUSING, WET LOCATION LISTED. G WL 1'-4" 10" 10 1/2" 16 W FIX LED 1 2500 277 V 0-10V GARDCO GEOFORM GBM S4E SAME AS S4 EXCEPT CONNECTED TO EMERGENCY POWER. G WL 1'-4" 10" 10 1/2" 16 W FIX LED 1 2500 277 V 0-10V GARDCO GEOFORM GBM NOTES: 1. {L##} DENOTES THE LIGHTING SEQUENCE OF OPERATIONS FOR THIS SPACE. 2. VERIFY AND COORDINATE DAYLIGHT LEVELS FOR PHOTOCELL ACTIVATION WITH OWNER PRIOR TO FINAL PROGRAMMING. 3. VERIFY AND COORDINATE ALL TIME CLOCK SETTINGS WITH OWNER PRIOR TO FINAL PROGRAMMING. LIGHTING SEQUENCE OF OPERATION PLAN ID LIGHTING SWITCHED {LE1} Sequence: Exterior switched lights are controlled photocell on, time clock off. ON: The lights automatically turn on when insufficient daylight is available. ADJUST: Lights dimmed to 50% output between 12AM and 6AM. OFF: The lights will turn off by timeclock. NO SCALE POLE BASE DETAIL1 NO. ISSUED FOR DATE SITE PLAN REVIEW 06/16/2023 SITE PLAN REVIEW RC1 01/30/2024 SITE PLAN REVIEW RC2 04/26/2024 SITE PLAN REVIEW RC3 10/31/2024 10/31/2024