Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
055 - E0.0.0 - ELECTRICAL COVERSHEET
BUILDING CODE:IBC 2021 EDITION FIRE CODE:IFC 2021 EDITION PLUMBING CODE:IPC 2021 EDITION MECHANICAL CODE:IMC 2021 EDITION ELECTRICAL CODE:NEC 2020 EDITION ENERGY CONSERVATION CODE:IECC 2021 HEALTH DEPARTMENT CODE:CURRENT EDITION LOCAL BUILDING CODE:CURRENT EDITION APPLICABLE CODES CONTRACTOR SHALL COMPLY WITH APPLICABLE CODES AND LOCAL AMENDMENTS. PLAN OR DETAIL NUMBER PLAN OR DETAIL NAME PLAN OR DETAIL SCALE DETAIL REFERRED TO BY SECTION CUT SHEET DETAIL IS LOCATED ON NAME 1 VIEW NAME 1/8" = 1'-0" 1 M101 143 2 SIMSIM INDICATES SIMILAR DETAIL REFERENCED IN MULTIPLE LOCATIONS LEVEL NAME 10'-0"HEIGHT ABOVE PROJECT 0'-0" 1 INDICATES NOTE USED TO DESCRIBE ADDITIONAL INFORMATION ABOUT WORK REQUIRED, SPECIFIC TO THE SHEET AND/OR DETAIL NOR HT INDICATES DIRECTION OF TRUE NORTH VIEW KEY LINE TYPE AND TAG KEY: NEW WORK BY THIS CONTRACTOR (WIDE LINE) NEW EXISTING TO BE REMOVED (SHORT DASHED PATTERN) NEW UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN) EXISTING TO REMAIN OR WORK BY OTHERS (NARROW LINE) EXISTING EXISTING TO BE REMOVED BY OTHERS (SHORT DASHED PATTERN) EXISTING UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN) HALFTONING DOES NOT MODIFY SCOPE. 'TAG'-E TAGS WITH DASH 'E' INDICATES THE REFERENCED OBJECT IS EXISTING TAG UNDERLINED TAG INDICATES OBJECT IS IN-SCOPE. IF NEW, ADDITIONAL INFORMATION IS AVAILABLE IN A SCHEDULE, MATERIAL LIST, OR SYMBOL LIST INDICATES AN EXISTING SYSTEM'S POINT OF CONNECTION/REMOVAL T101 1. REFER TO SHEET E-1.1.3 FOR LUMINAIRE SCHEDULE. 2. { L##} DENOTES THE LIGHTING SEQUENCE OF OPERATIONS FOR THIS SPACE. REFER TO SHEET E-1.1.3. ELECTRICAL MOUNTING SUBSCRIPT KEY: A MOUNT AT +6" TO CENTERLINE ABOVE COUNTER OR BACKSPLASH C MOUNT AT CEILING H MOUNT ORIENTED HORIZONTALLY EWC ELECTRIC WATER COOLER ELECTRICAL GENERAL NOTES: LUMINAIRE F1 = FIXTURE TAG 1 = CIRCUIT NUMBER a = SWITCH DESIGNATION NL = SUBSCRIPT (IF APPLICABLE) Z = ZONE DESIGNATION *IF LABEL IS ORIENTED HORIZONTALLY A SLASH WILL SEPARATE THIS INFORMATION. EX: F1 / 1 / a / NL DEVICE A = MOUNTING (IF APPLICABLE) 1 = CIRCUIT NUMBER *IF LABEL IS ORIENTED HORIZONTALLY A SLASH WILL SEPARATE THIS INFORMATION. EX: A / 1 LUMINAIRE KEY: DEVICE KEY: 1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADA STANDARDS FOR ACCESSIBLE DESIGN. 2. CIRCUIT NUMBERS ARE SHOWN FOR CIRCUIT IDENTIFICATION. CIRCUITING SHALL AGREE WITH NUMBERING ON THE PANEL PROVIDED. COMMON NEUTRALS MAY NOT BE USED FOR BRANCH CIRCUITS. BALANCE THE LOAD ON PANEL AS EVENLY AS POSSIBLE BETWEEN EACH PHASE. 3. EQUIPMENT BRANCH WIRING FOR FEEDERS AND BRANCH CIRCUITS SHALL BE ROUTED IN SEPARATE RACEWAY, JUNCTION BOXES, PULL BOXES, AND CABINETS. WIRING FOR EACH BRANCH SHALL BE INDEPENDENT FROM OTHER BRANCHES, INCLUDING THE NORMAL BRANCH. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR SEALED INTO OPENINGS. 5. ALL WELDING SHALL BE ACCORDING TO AMERICAN WELDING SOCIETY STANDARDS. CONTRACTOR SHALL FURNISH TO THE ARCHITECT/ENGINEER CERTIFICATES QUALIFYING EACH WELDER, PRIOR TO START OF WORK. THE ARCHITECT/ENGINEER RESERVES THE RIGHT TO REQUIRE QUALIFYING DEMONSTRATION, AT THE CONTRACTOR'S EXPENSE, OF ANY WELDERS ASSIGNED TO THE JOB. 6. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO THE WALLS, FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE IS RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE RATING, AND FINISH. ELECTRICAL INSTALLATION NOTES: SW-1P 26 09 33 SWITCH -SINGLE POLE SW-2P 26 09 33 SWITCH -TWO POLE2 SW-3W 26 09 33 SWITCH -THREE WAY3 SW-4W 26 09 33 SWITCH -FOUR WAY4 SW-1P-WP 26 09 33 SWITCH -WEATHERPROOFW SW-1P-EX 26 09 33 SWITCH -EXPLOSION PROOFX SW-1P-PL 26 09 33 SWITCH -PILOT LIGHTP SW-1P-ADJ 26 09 33 SWITCH -LOCAL TIMER -USER ADJUSTABLET SW-OC-P-O SWITCH -OCCUPANCY SENSOR WALL SWITCHO SW-OC-P-O2 SWITCH -OCCUPANCY SENSOR AND DUAL SWITCHO2 OC SW-OC-P-P OCCUPANCY SENSOR -PASSIVE INFRARED 360 DEGREE COVERAGEP OC SW-OC-U OCCUPANCY SENSOR -ULTRASONIC 360 DEGREE COVERAGEU OC SW-OC-U2 OCCUPANCY SENSOR -ULTRASONIC 35'X30' HAND MOTION COVERAGEU2 OC SW-OC-U-A OCCUPANCY SENSOR -ULTRASONIC TWO SIDED CORRIDOR COVERAGEA OC SW-OC-D OCCUPANCY SENSOR -DUAL TECHNOLOGYD OC SW-OC-P-HB OCCUPANCY SENSOR -HIGH BAYHB OC SW-OC-P-HA OCCUPANCY SENSOR -HIGH BAY AISLE COVERAGEHA LS SW-LS DAYLIGHT LEVEL SENSOR LS SW-LS-D DAYLIGHT LEVEL SENSOR -1 ZONE DIMMINGD 26 09 33 26 09 33 26 09 33 26 09 33 26 09 33 26 09 33 26 09 33 26 09 33 26 09 33 SW-1P-K SWITCH -SINGLE POLE -KEY LOCK 26 09 33K SW-2P-K SWITCH -TWO POLE -KEY LOCK K2 SW-3W-K SWITCH -THREE WAY -KEY LOCK K3 SW-4W-K SWITCH -FOUR WAY -KEY LOCK K4 SW-LS-PC PHOTOCELL26 09 33PC 26 09 33 26 09 33 26 09 33 CB-#26 28 16 CIRCUIT BREAKER -SURFACE MOUNTED. REFER TO DISC/STA SCHEDULE CB-#26 28 16 CIRCUIT BREAKER -FLUSH MOUNTED. REFER TO DISC/STA SCHEDULE DS-#/FDS-#/DSS-#26 28 16 DISCONNECT. REFER TO DISC/STA SCHEDULE SW-OC-D-W OCCUPANCY SENSOR -DUAL TECHNOLOGY -WALL MOUNTEDD26 09 33OC SW-OC-P-W OCCUPANCY SENSOR -PASSIVE INFRARED - WALL MOUNTEDP26 09 33OC SW-OC-U-W OCCUPANCY SENSOR -ULTRASONIC -WALL MOUNTEDU26 09 33OC 26 09 33 26 09 33 SW-D-LED DIMMER -LEDD26 09 33 SW-D3-LED DIMMER -LED -3-WAYD326 09 33 ELECTRICAL SYMBOL LIST SYMBOL:TAG:SPEC SECTION:DESCRIPTION: SW-DCS DIMMER CONTROL STATION26 09 33#B TC-#TIME SWITCH 26 09 33TC RI-TV 26 05 33 TV ANTENNA OUTLET ROUGH-INTV FB-#or PT-#26 27 26 FLOOR BOX or POKE THROUGH JB 26 05 33 JUNCTION BOXJ J ECONN 26 05 33 ELECTRICAL CONNECTIONE E WW-#26 05 35 ELECTRICAL WIREWAY w/ DEVICES SHOWN WM-#26 05 35 MULTI OUTLET SYSTEM RI-TECH-C 26 05 33 TECHNOLOGY ROUGH-IN, CEILINGRIRI DPM 26 09 13/ 26 24 13 DIGITAL POWER METERDPM PANEL '###'26 24 16 PANELBOARD -SURFACE MOUNT PANEL '###'26 24 16 PANELBOARD -RECESS MOUNT GB 26 05 26 GROUND BUSGB IBT 26 05 26 INTERSYSTEM BONDING TERMINATIONIBT PB PB 26 09 16 MOMENTARY PUSHBUTTON OPERATOR MX-#/MS-# /CB-#/CS-# 26 24 19 MANUAL SWITCH / STARTER / COMBINATION STARTER/ CIRCUIT BREAKER. REFER TO DISC/STA SCHEDULE LCP-#26 09 33 LIGHTING CONTROL PANEL ELECTRICAL SYMBOL LIST SYMBOL:TAG:SPEC SECTION:DESCRIPTION: MPC-#26 24 23 PACKAGED POWER CENTER DEM DEM ENERGY METER26 09 13 TR-#/DTR-#26 22 00 TRANSFORMER. REFER TO TRANSFORMER SCHEDULE SW-OD DIMMER -WALL DIMMER OCCUPANCY SENSORO26 09 33 SW WALL CONTROL STATION26 09 33SW SW-LV 26 09 33 LOW VOLTAGE SWITCHLV LINEAR LUMINAIRES TROFFER WALL SCONCE LUMINAIRE DOWNLIGHT LUMINAIRE AIMABLE OR WALL WASH LUMINAIRE INDUSTRIAL LUMINAIRE POLE MOUNTED LUMINAIRE SINGLE FACE EXIT SIGN DOUBLE FACE EXIT SIGN EMERGENCY UNIT WALL BRACKET LUMINAIRE ELECTRICAL SYMBOL LIST SYMBOL:TAG:SPEC SECTION:DESCRIPTION: WALL/CEILING EMERGENCY EXIT SIGN REC-DUP-GFI-R 26 27 26 GROUND FAULT DEVICEG REC-TAMP 26 27 26 DUPLEX RECEPTACLE, TAMPER RESISTANT, 125V REC-TAMP-GFI 26 27 26 GFI DUPLEX RECEPTACLE, TAMPER RESISTANT, 125V REC-TAMP-QUAD 26 27 26 QUAD RECEPTACLE, TAMPER RESISTANT, 125V REC-ISO- SUR-QUAD 26 27 26 ISOLATED GROUND QUAD RECEPTACLE WITH SURGE SUPPRESSION, 125V REC-DUP 26 27 26 DUPLEX RECEPTACLE, 125V REC-DUP-XP 26 27 26 DUPLEX RECEPTACLE, EXPLOSION PROOF, 125V REC-DUP-GFI 26 27 26 DUPLEX GFI RECEPTACLE, 125V REC-DUP-WP 26 27 26 DUPLEX GFI WEATHERPROOF RECEPTACLE 125VW REC-ISO 26 27 26 ISOLATED GROUND RECEPTACLE, 125V REC-ISO-SUR 26 27 26 ISOLATED GROUND RECEPTACLE WITH SURGE SUPPRESSION, 125V REC-QUAD 26 27 26 QUAD RECEPTACLE, 125V REC-QUAD-GFI 26 27 26 QUAD GFI RECEPTACLE, 125V REC-SIM-520R 26 27 26 SIMPLEX RECEPTACLE, 125V ELECTRICAL SYMBOL LIST SYMBOL:TAG:SPEC SECTION:DESCRIPTION: REC-USB 26 27 26 DUPLEX RECEPTACLE, USB CHARGING X S S U DUPLEX RECEPTACLE CONTROLLED BY OCCUPANCY O REC-DUP-O 26 27 26 REC-PED-QUAD 26 05 33 RECEPTACLE -PEDESTAL STYLE REC-DUP-PED 26 05 33 RECEPTACLE -PEDESTAL STYLE REC-ARC 26 27 26 ARC FAULT CIRCUIT INTERRUPTER RECEPT 125V REC-QUAD-USB 26 27 26 QUAD RECEPTACLE, USB 125V U REC-QUAD-WP 26 27 26 QUAD GFI WEATHERPROOF RECEPTACLE, 125VW REC-Z#26 27 26 IEC PIN AND SLEEVE RECEPTACLE, 600V# PP#26 27 23 POWER POLE QUAD RECEPTACLE CONTROLLED BY OCCUPANCY O REC-QUAD-O 26 27 26 REFER TO LUMINAIRE SCHEDULE RI RI-TECH 26 05 33 TECHNOLOGY OUTLET ROUGH-IN EPO 26 09 16 26 32 13 EMERGENCY STOP / POWER OFF (N.C. AND N.O. CONTACT) PP ARCH PUSH PADPP DB ARCH DOOR BELLDB HD ARCH HAND DRYERHD GANN-#26 32 13 GENERATOR ANNUNCIATOR PANEL GANN REC-AFGF 26 27 26 REC AFCI, GFCI, TAMPER RESISTANTAF ATF-#26 22 00 AUTOMATIC TRANSFER SWITCH IMEG RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG AND SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG. ©2024 IMEG CONSULTANTS CORP. REF. SCALE IN INCHES 0 1 2 3 N E C PROJECT DRAWING PROJ. NO. SHEET GENERAL NOTES ISSUANCES DATE B A 1 E D C B A PROJECT TEAM © 2023 COPYRIGHT G|R|E|C ARCHITECTS BUILDING DEPT STAMP D SEAL 1. THIS DOCUMENT WITH THE ACCOMPANYING DRAWINGS, SPECIFICATIONS AND/OR PROJECT MANUAL, DESCRIBES THE GENERAL SCOPE OF THE PROJECT AND DESIGN CONCEPT AND DESIGN CONCEPT IN TERMS OF THE INTERIOR DESIGN, ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS. THESE DOCUMENTS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL OF THE WORK REQUIRED FOR THE FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE SCOPE INDICATED, DESCRIBED OR INFERRED, THE CONTRACTOR SHALL DETERMINE AND INCLUDE IN THE PROPOSALS ALL ITEMS NECESSARY TO PROVIDE PROPER EXECUTION AND COMPLETION OF THE WORK. 2. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONFIRM ANY EXISTING SITE CONDITIONS, AND SHALL NOTIFY THE ARCHITECT OF ANY DIMENSIONAL DISCREPANCIES PRIOR TO BEGINNING WORK. GR E CArchitects| | | OWNE 2345678 12345678 PROJECT #23008933.00 10/31/2024 5:30:53 PM Autodesk Docs://2215 - Bozeman MT/MEPT24_22008933.00_GREC-Bozeman-MT-Hotel Bozeman_C.rvtHOTEL BOZEMAN 205 N TRACY AVE. BOZEMAN, MT E0.0.0 ELECTRICAL COVERSHEET 2215 ARCHITECT G|R|E|C ARCHITECTS, LLC INTERIOR DESIGN G|R|E|C ARCHITECTS, LLC STRUCTURAL ENGINEER D'AMATO CONVERSANO INC. MEPFP ENGINEER IMEG CORP. CIVIL ENGINEER STAHLY ENGINEERING & ASSOCIATES LANDSCAPE ARCHITECT DESIGN.5 LANDSCAPE ARCHITECTURE HOTEL BOZEMAN INVESTORS, LLC NO. ISSUED FOR DATE SITE PLAN REVIEW 06/16/2023 SITE PLAN REVIEW RC1 01/30/2024 SITE PLAN REVIEW RC2 04/26/2024 SITE PLAN REVIEW RC3 10/31/2024 10/31/2024