HomeMy WebLinkAbout035 - L602 - Level 3 Irrigation PlanDNUPDNUPUPGUESTROOMTYPE 2H302GUESTROOMTYPE 3H303GUESTROOMTYPE 3H304GUESTROOMTYPE 3H305GUESTROOMTYPE 3 - ADAH306GUESTROOMTYPE 4H307GUESTROOMTYPE 5H308GUESTROOMTYPE 6H309GUESTROOMTYPE 7H310GUESTROOMTYPE 7H311GUESTROOMTYPE 7H312GUESTROOMTYPE 7H313GUESTROOMTYPE 7H314GUESTROOMTYPE 6H316GUESTROOMTYPE 4H317GUESTROOMTYPE 3H318GUESTROOMTYPE 3H319GUESTROOMTYPE 3H320GUESTROOMTYPE 3H321GUESTROOMTYPE 4H322GUESTROOMTYPE 8H323GUESTROOMTYPE 9H324GUESTROOMTYPE 10H325GUESTROOMTYPE 11 - ADAH326GUESTROOMTYPE 11H327ELECH332STAIR 02ST-02ELECR301STAIR 03ST-03STAIR 04ST-04X02 - 2NDBEDROOMR302.1X02 - 2 BEDR302X01 - 3 BEDR301X01 - 3RDBEDROOMR301.1X03 - 2NDBEDROOMR303.1X03 - 2 BEDR303X04 - 2 BEDR304X04 - 2NDBEDROOMR304.1X02 - 2 BEDR305X02 - 2NDBEDROOMR305.1X06 - 2NDBEDROOMR306.1X06 - 2 BEDR306307 - 2 BEDTYPE AR307307 - 2NDBEDROOMTYPE AR307.1583 SFGUESTROOMTYPE 1H301423 SFGUESTROOMTYPE 6H315424 SFGUESTROOMTYPE 10H328WEST LAMME STREETWEST BEALL STREETNORTH TRACY AVENUETHE HOTELBOZEMANRESIDENCESTHE HOTELBOZEMANGREEN ROOF TO BE IRRIGATEDWITH SPRAY IRRIGATION SYSTEM.GREEN ROOF TO DRAIN TO AREA DRAINS.IRRIGATION NOTES AND SPECIFICATIONS2.THE IRRIGATION DESIGN INTENT IS TO HAVE 4 VALVES ON LEVEL 1 SO THAT THERE ARE 2 VALVES ( ONE FOR TREES AND ONE FORPERENNIALS) FOR EACH OF THE STREETSCAPE FRONTAGES. THE INTENT IS TO HAVE 3 VALVES ON LEVEL 3 ( ONE FOR SHADEDPERENNIALS, ONE FOR THE SUNNY PERENNIALS AND ONE FOR THE TREE.3.ALL VALVE BOXES TO BE STANDARD SIZE OR LARGER.4.IRRIGATION MAIN LINE TO BE 1.5" SCH. 40 PVC PIPE OR 150 PSI POLY PIPE.5.ALL TREES TO BE IRRIGATED THROUGH DEDICATED BUBBLERS. BUBBLERS TO BE EVENLY DISTRIBUTED AROUND BASE OF TREE WITHFOUR (4) EVENLY SPACED BUBBLERS/EMITTERS.6.TREES AND SHRUBS PLACED WITHIN PLANTING BEDS MAY UTILIZE DRIP IRRIGATION. DRIP IRRIGATION TO BE ADJUSTED PERREQUIREMENTS OF EACH INDIVIDUAL PLANT.7.ALL SHRUBS OUTSIDE OF DEDICATED PLANTING BEDS TO HAVE DEDICATED BUBBLERS. BUBBLERS TO BE EVENLY DISTRIBUTED AROUNDBASE OF SHRUB WITH TWO (2) EVENLY SPACED BUBBLERS/EMITTERS.8.ALL MIXED SHRUB AND PERENNIAL PLANTINGS TO BE IRRIGATED WITH DEDICATED DRIP TUBING. DRIP EMITTERS TO BE ADJUSTED PERREQUIREMENTS OF EACH INDIVIDUAL PLANT.RECOMMENDED EMITTERS PER PLANT TYPE:PERENNIALS- (1) 0.5 GPH EMITTERSHRUBS- (2) 1.0 GPH EMITTERS/0.25-1.0 GPM BUBBLERSTREES- (4) 1.0 GPH EMITTERS/0.25-1.0 GPM BUBBLERS***TREES UTILIZING DRIP IN PLANTING BEDS MAY NEED ADDITIONAL EMITTERS TO MEET WEEKLY WATERING REQUIREMENTS.9.SYSTEM SHALL UTILIZE A "SMART" CONTROLLER WITH WI-FI AND AUTOMATIC SCHEDULING CAPABILITIES THAT CORRESPOND TOCHANGES IN LOCAL WEATHER CONDITIONS10.SYSTEM SHALL UTILIZE WEATHER / MOISTURE MONITOR, VERIFY BEST LOCATION IN FIELD.11.BACK FLOW ASSEMBLY AND BLOWOUT ASSEMBLY SHALL BE LOCATED IN MECHANICAL ROOM OR APPROVED EXTERNAL GRADE BOX. IT ISTHE RESPONSIBILITY OF THE LANDSCAPE CONTRACTOR TO COORDINATE INSTALLATION PER LOCAL CODES AND ORDINANCES AS WELLAS WITH ARCHITECTURE AND ALL OTHER TRADES.12.POWER SOURCE FOR IRRIGATION CONTROLLER TO BE COORDINATED WITH ELECTRICAL ENGINEER, ELECTRICAL CONTRACTOR ANDLANDSCAPE CONTRACTOR.13.DO NOT INSTALL IRRIGATION SYSTEM WHEN OBVIOUS OBSTRUCTIONS OR GRADE CHANGES ARE PRESENT.14.ALL INFORMATION TO BE FIELD-VERIFIED BY CONTRACTOR PRIOR TO INSTALLATION.15.THE CONTRACTOR SHALL MAINTAIN AN ACCURATE & CURRENT 'AS-BUILT' IRRIGATION PLAN ON SITE AT ALL TIMES.D SYM DESCRIPTIONIRRIGATION LEGEND - LEVEL 2-6DRIP LINE, SOFT WALL DRIP TUBINGIRRIGATIONTYPEIRRIGATION SCHEDULE - LEVEL 3TOTALAREA / QTYANNUALET RATETOTALANNUAL H2O0 TREES16.5 GAL /WEEK0 GAL0 SHRUBS7.5 GAL /WEEK0 GAL0PERENNIALS2 GAL /WEEK0 GALTOTAL ANNUAL H2O REQUIRED: 25,312 GALTOTAL ACRE FEET PER YEAR: 0.08 ACRE FEETH.E. TREEBUBBLERH.E. SHRUBDRIP IRRIG.H.E.PERENN.DRIP IRRIG.1,401 SF29 IN / SF25,312 GALH.E. GREEN
ROOF SPRAY
IRRIGATION
Level 3Irrigation PlanL 602design5la.com406.587.4873dateissuedrawn by:checked by:filename:z:\north central hotel bozeman & residences\autocad\01_sheets\l600_hotel-bozeman_irrigation.dwg
North Central
The Hotel Bozeman & Residences
Bozeman, Montana
KHM/HU TMS
01/27/23SD Check Set02/10/23100% SD06/19/23SP1168032N1L6021/16" = 1'-0"Level 3 Irrigation Plan