Loading...
HomeMy WebLinkAbout014 A1.00 - Floor Plan#45A #45A #45A #45A #45A #45A MUSICS127ARTS126COMPUTERSS124CLASSROOMS101CLASSROOMS104CLASSROOMS103MECHS105CLASSROOMS109RESTROOMS115OFFICES137OFFICES135OFFICES138ADVISINGSUITES140WORKS134RECEPTIONS133FLEX HALL3S119STORAGES106STORAGES113STORAGES129STORAGES121cA2.1061A3.002A3.101A3.30WORK/COPYS107FLEX HALL1S108RESTROOMS114OFFICES136TESTINGS141TESTINGS143CLASSROOMS125HALLS1181A3.202A3.40A2.1072A3.21WARMING KITCHENS128PREPS122STORAGES123STORAGES147CONFERENCES130TESTINGS142RESTROOMS148OFFICES145ENTRY VESTIBULES144CLASSROOMS111CLASSROOMS112CLASSROOMS110CLASSROOMS102A7.703A7.702A7.001A7.701WAITING AREAS130AS124S121S120AS122S123S127BS145S142S141S140S143S148S147S130S135S136S137S138S115BS115AS111S109S110S112S114S105S106S103S101S104S102S113S128BS128DS128AS126AS129S151AS127AS120BS151BS246EXISTING ELECTRICALS150EXISTING CLASSROOM61A4.00S125(18) LOCKERS(18) LOCKERS(20) LOCKERS(20) LOCKERS(17) LOCKERS(17) LOCKERS(8) LOCKERS(13) LOCKERS(13) LOCKERS3'-0" X 3'-0" ROOF HATCH ABOVE - SEE DETAIL ON SHEET A6.20LADDER UP TO ROOF -SEE DETAIL ON SHEET A6.20A7.306A7.305A7.301FLEX HALL 2S151A7.501A7.401S1SFSG.6S6S7..A2.102S116HALLS116HALLS117S144BS144AS144CS144DS130AS151DS151CS119S108A2.108S128CE.2A4.00SIM.2A4.00SIM.2A4.00SIM.A7.807A2.1013'-0" X 3'-0" ROOF HATCH ABOVE - SEE DETAIL ON SHEET A6.20LADDER UP TO ROOF -SEE DETAIL ON SHEET A6.20A2.201A2.205A2.1015A2.2012A1.3121A3.404A3.201A3.102A3.30A7.601EEEEEEES4S2S5SASBSCSDSLSESHSISMSJSKHALLS1543A3.21BBBBBBBBBBBBBBCCDBBBBBBBBAABBCCCAAC1C2C1C8C32A4.00SIM.2A4.00SIM.2A4.00SIM.2A4.00SIM.2A4.00SIM.2A4.00SIM.2A4.00SIM.3A4.004A4.00DS126BC7C5C4S154PLANTING AREA / TREE GROVE0'4'-0"8'-0"16'-0"SCALE: 1/8" = 1'-0"A8.2031S105AC15OPERABLE PARTITIONEXISTING BUILDINGTESTING HALLS1522A3.002A3.00OPPSIMA7.8023PROJECTION WHITEBOARDSSEE ELEVATIONA7.8073SIMOPPPROJECTION WHITEBOARDSSEE ELEVATIONA7.807PROJECTION WHITEBOARDSSEE ELEVATION3SIMOPPSIMOPPA7.8073SIMOPPSIMOPPPROJECTION WHITEBOARDSSEE ELEVATIONA7.8073A7.8073A7.8073A7.8073PROJECTION WHITEBOARDSSEE ELEVATIONPROJECTION WHITEBOARDSSEE ELEVATIONPROJECTION WHITEBOARDSSEE ELEVATION.FURR OUT AT THIS LOCATION TO BE IN PLANEWITH COLUMN FURRINGPROJECTION WHITEBOARDSSEE ELEVATION22" DEEP CABINETSEE ELEVATION22" DEEP CABINETSEE ELEVATION22" DEEP CABINETSEE ELEVATION22" DEEP CABINETSEE ELEVATION22" DEEP CABINETSEE ELEVATION22" DEEP CABINETSEE ELEVATION22" DEEP CABINETSEE ELEVATION16" DEEP CABINET(THIS LOCATION ONLY). SEE ELEVATION3A3.10SIM.4A3.21SIM.1A3.21SIM.3A3.30SIM.4A3.30SIM.2A4.40NOTE: TYP. AT ALL WINDOW CLOCATIONS NOTE: TYP. AT ALL WINDOW BLOCATIONS A7.808PROJECTION WHITEBOARDSSEE ELEVATIONA7.801097A5.007A5.00A7.309A7.309SIMA7.305SIMA7.305SIMA7.309SIMA7.305SIMA7.305SIMA7.306SIMDATESHEET NO.PROJECT #DATE12345NO.6DESCRIPTIONDRAWN CHECKED REVISIONSPROCESS DRAWINGS; NOT FOR CONSTRUCTIONAutodesk Docs://Petra Academy/231216 PETRA SECONDARY EXPANSION 2.0 UPDATED CRAIG.rvtA1.00FLOOR PLAN.230105/21/24SECONDARYBUILDINGEXPANSION4720 CLASSICALWAYBOZEMAN, MT59718PETRA ACADEMY0'4'-0"8'-0"16'-0"SCALE: 1/8" = 1'-0"NORTHGENERAL SHEET NOTES:1. SEE EXTERIOR ELEVATIONS FOR HIGH WINDOWS ON EXTERIOR OF BUILDING2. ALL INTERIOR FRAMING SHOWN 3 5/8" AND 6" METAL STUDS (SEE WALL TYPES SHEET)3. ALL INTERIOR WALLS INSULATED WITH R13 (3 5/8" WALLS) AND R19 (6" WALL) UNFACED BATT INSULU.N.O.4. ALL STEEL COLUMNS TO BE APPEARANCE WRAPPED TO DECK (EXPOSED CEILING AREAS) OR TO12" ABOVE FINISH CEILING5. SEE C&H STRUCTURAL DRAWINGS FOR ALL STEEL LOCATIONS & FINISH HEIGHTS.6. ALL FIRE EXTINGUISHERS INSTALLED IN SEMI-RECESSED CABINETS.7. ALL WALLS ARE DIMENSIONED TO EDGE OF METAL STUD8. ALL EXTERIOR WALLS ARE 6" KORETECK WALL PANEL SYSTEM, EXCEPT CURVED CURTAIN WALLSAND CLERESTORY FRAMINGFLOOR PLAN KEYED NOTESNOTE # NOTE DESCRIPTION1 METAL STUD FRAMED EXTERIOR WALL2 WHITE BOARD LOCATION, SEE INTER CLASSROOM DETAILS3 ROOF DRAIN PIPING, SEE ROOF PLAN/ PLUMBING PLANS FOR DETAILS4 DOUBLE TACK STRIPS. MOUNT CENTER LINES AT 4'-10" AND 6'-4" SIM TOCLASSROOMS.5 EXTERIOR WALL MOUNTED SECURITY CAMERA. SEE ELEVATIONS FORCLARITY. BLOCKING REQUIREMENTS ARE AS FOLLOWS: AT METAL STUDWALLS, PROVIDE 18 GA. FLAT STRAP STEEL BETWEEN STUDS PRIOR TOSHEATHING. AT KORETECK WALLS, EXTEND ELECTRICAL BOX TO PANELCORE, INSTAL FINISH RINGS TO FLUSH ELECTRICAL BOX WITH WALL FINISH.6 INTERIOR SURFACE MOUNT WALL MOUNTED SECURITY CAMERA. BLOCKINGREQUIREMENTS ARE AS FOLLOWS: AT METAL STUD WALLS, PROVIDE 18 GA.FLAT STRAP STEEL BETWEEN STUDS PRIOR TO SHEATHING. AT KORETECKWALLS, EXTEND ELECTRICAL BOX TO PANEL CORE, INSTAL FINISH RINGS TOFLUSH ELECTRICAL BOX WITH WALL FINISH.7 CEILING MOUNTED SECURITY CAMERA. BLOCKING REQUIREMENTS ARE ASFOLLOWS: METAL STUD FRAMED CEILING PROVIDE 18 GA FLAT STRAP STEELBETWEEN STUDS PRIOR TO DRYWALL. AT LAY-IN CEILINGS, PROVIDE T-BARSUSPENSION TIES TO CENTER CAMERAS IN CEILING TILES.1/8" = 1'-0"A1.001FLOOR PLANGENERAL SHEET NOTES:9. ALL GLAZING IN DOORS AND WINDOWS WITHIN 24" OF DOORS SHALL BE SAFTEY GLAZED,TEMPERED AND PASS TEST REQUIREMENTS OF ANSI 297.110. ALL FIRE RATED DOORS SHALL HAVE RATED FRAMES, HARDWARE, CLOSERS AND OTHER RATEDACCESSORIES, SEE DOOR & HARDWARE SCHEDULE.11. PROVIDE IMPACT RESISTANT TYPE 'X' GYPSUM BOARD TO 8'-0" AFF IN ALL CORRIDORS.12. ALL PERIMETER COLUMN BASE PLATES @ T.O. SLAB. ALL INTERIOR COLUM BASE PLATESRECESSED 6" BELOW T.O. SLAB. FRAME & GYPSUM WALLBOARD AROUND FULL BASE PLATEDIMENSION ON EXT. COLUMNS.13. SEE SHEET A2.02 FOR INTERIOR PARTITION TYPES.14 CASEWORK IN SCIENCE, PREP, AND ART: REFER TO SPECIFICATION "WOOD LABORATORYCASEWORK"; CASEWORK IN CLASSROMS: REFER TO SPECIFCATION "INTERIOR ARCHITECTURALWOODWORK1509/16/24