HomeMy WebLinkAbout013 L304 - Irrigation Details IRRIGATIONDETAILSL304DATE3084 Thorpe RoadBelgrade, Montana 59714406.924.8038aly@outdoordesignstudios.comISSUEDrawn By: SSChecked By: JDPETRA ACADEMY
4720 Classical Way
Bozeman, MT 123441L30412C-800-MICC2 HUNTER CONTROLLER NTS1.IRRIGATION CONTROLLER(12C-800-M) PER PLAN2.IRRIGATION CONTROL WIRE INCONDUIT SIZE AND TYPE PERLOCAL CODES3.ELECTRICAL SUPPLY CONDUITCONNECT TO POWERSOURCE, J-BOX INSIDECONTROLLER4.ADJACENT SURFACE TOMOUNT CONTROLLER PERPLANNOTES:MOUNT CONTROLLER LCD SCREEN ATEYE LEVEL, CONTROLLER SHALL BEHARD-WIRED TO GROUNDED 110 VACPOWER SOURCEFRONT ELEVATIONRIGHT ELEVATION13" OPEN DOOR WIDTH5" WIDTH10111357731263113124577226918134FLOW1.HUNTER HC FLOW METER HC-100WITH UNION CONNECTIONS2.SCH 80 PVC FEMALE ADAPTER(S X T)3.RECTANGULAR VALVE BOX PERSPECIFICATIONS4.SCH 80 PVC 45 DEGREE ELBOW(S X S) TO LOWER MAIN LINE TOPROPER DEPTH (SIZE FOR LARGERMAIN LINE AS NEEDED)5.SCH 80 PVC 45 DEGREE ELBOW(S X S) TO LOWER MAIN LINE TOPROPER DEPTH6.1.5" DIA. (40 mm) MAIN LINE ATINLET & OUTLET7.MAIN LINE TO SYSTEM (SEE LEGENDAND PLANS FOR TYPE AND SIZE)8.TWO WIRES TO FLOW SENSORTERMINALS AT CONTROLLER. MIN.18 AWG-UF (2.08 mm²) SHIELDEDWIRE WITH DIFFERENT COLOR FROMCONTROL/COMMON WIRE9.WEATHERPROOF WIRE CONNECTOR10.FINISH GRADE11.SPECIFIED SOIL COVER (SEELEGEND)12.COMMON BRICK13.GRAVEL BASE, 6" (15 CM) DEEPNOTES:1.INLET PIPE ENTERING METER LENGTH MUST BE A MIN. OF 10xPIPE DIA.2.OUTLET PIPE LEAVING METER MUST BE MIN. OF 5x PIPE DIA.INLET AND OUTLET PIPE MUST BE STRAIGHT PIPE WITH NOFITTINGS OR TURNS UNTIL AFTER THESE SPECIFIED LENGHTS.3.PIPE AND FITTINGS MAY BE SCH 80 PVC SOLVENT WELD,THREADED SCH 80 PVC OR PRASS, AS REQUIRED FORPROJECT.10 xPIPE DIA.5 xPIPE DIA.TOP VIEWSIDE VIEW2L304HC-100 FLOW METER NTS12343L304WITH GENERIC WALL MOUNT CONTROLLERSOLAR SYNC NTS1.SOLAR SYNC SENSOR2.SOLAR SYNC COMPATIBLECONTROLLER3.POST OR SUITABLEMOUNTING SURFACE4.FINISHED GRADE5L304ICZ-101-LFDRIP CONTROL ZONE KIT NTS1151210986776342151.HUNTER REMOTE CONTROLVALVE (ICZ) WITH FILTERREGULATION2.IRRIGATION VALVE BOX:HAT STAMP LID WITH 'RCV'IN 2-INCH LETTERS3.WATERPROOFCONNECTORS (2)4.18-IN TO 24-IN COILEDWIRE TO CONTROLLER5.FINISH GRADE ATADJACENT SURFACE (TURFOR MULCH)6.SCH 80 CLOSE NIPPLE,MATCH SIZE TO VALVE7.PVC SLIP X FPT ADAPTER8.BRICK SUPPORTS (4)9.FILTERED FABRIC - WRAPTWICE AROUND BRICKSUPPORTS10.3/4-INCH WASHED GRAVEL- 4-IN MIN. DEPTH11.IRRIGATION LATERAL12.MAIN LINE LATERAL ANDFITTINGS6L304ICD-200 DECODER NTS1.HUNTER DECODER (ICD-200)PER PLAN2.HUNTER DECODER STAKE(DECRSTAKE-10) DRIVEN INTOVALVE BOX BASE GRAVEL/SOIL.SECURE DECODER TO STAKEWITH BOTTOM OF DECODERFACING UP AND FASTENED TOSTAKE USING TWO ZIP TIES3.INCOMING HUNTER JACKETEDIDWIRE PATH PER PLAN WITH36-INCH LOOP OF SLACKWIRE, MEASURED FROM TOPOF VALVE BOX, NEATLY COILEDINSIDE VALVE BOX4.RED AND BLUE WIRES FROMDECODER TO IDWIRE SPLICES5.BARE COPPER GROUND WIREFROM DECODER TOGROUNDING DEVICE, ROD ORPLATE, SEE PLAN FOR GROUNDLOCATIONS AND TYPE.6.STATION WIRE FROM DECODEROUTPUT TO VALVE SOLENOIDWIRES7.IDWIRE PATH SPLICE WITHDECODER OUTPUT USING 3MDBRY/6 INSTALLED PERMANUFACTURERSINSTRUCTIONS8.VALVE SOLENOID WIRE SPLICEWITH DECODER OUTPUT USING3M DBRY/6 INSTALLED PERMANUFACTURERSINSTRUCTIONS9.VALVE SOLENOID WIRE WITH18-INCH COIL TO SPLICE WITHDECODER OUTPUT10.STATION WIRE FROM DECODEROUTPUT TO VALVE SOLENOIDWIRES IN A SEPARATE VALVEBOX11.WIRE CONNECTION FROMDECODER OUTPUT TOSEPARATE SOLENOID SHALLBE 14 AWG, PE INSULATED12.OUTGOING HUNTER JACKETEDDWIRE PATH PER PLAN WITH36-INCH LOOP OF SLACKWIRE, MEASURED FROM TOPOF VALVE BOX,NEATLY COILEDINSIDE VALVE BOX13.IRRIGATION VALVE, VALVE BOX,AND RELATED ITEMS PERIRRIGATION PLAN AND DETAILSNOTES:A.CONTRACTOR SHALL INDICATE ASSOCIATED VALVENUMBER(S) ON MANUFACTURER PROVIDED LABEL ONDECODER WITH PERMANENT MARKERB.CONTRACTOR SHALL LOCATE SPLICE WITH DWIRE ANDDECODER OUTPUT IN THE MIDDLE OF 36-INCH IDWIRELOOP IN VALVE BOXC.CONTRACTOR SHALL CONNECT BARE COPPERGROUND WIRE FROM DECODER OUTPUT TO GROUNDDEVICE WIRE USING ERICO PG11L KIT PERMANUFACTURERS INSTRUCTIONSD.14 AWG PE WIRE DISTANCE FROM OUTPUT SOLENOIDTO SOLENOID IN SEPARATE VALVE BOX SHALL NOTEXCEED 150-FEETE.EARTH GROUND TO BE A MINIMUM OF 8 FEET AWAYFROM DECODER AND AT A RIGHT ANGLE TO THE TWOWIRE PATHF.GROUNDING SHALL BE INSTALLEDAT A MINIMUM OFEVERY 12TH DECODER OR 1,000-FEET, WHICHEVEROCCURS FIRST1398111389862112471235ISOLATION VALVE DETAIL NTS4L3041.FINISH GRADE2.VALVE BOX ASSPECIFIED3.GATE VALVE ASSPECIFIED. LINESIZE.4.SCH 80 PVCUNION (1 OF 2)5.MAIN LINE PIPE6.6" OF WASHED 34"AGGREGATE BASE7.BRICK SUPPORTS(1 OF 4)1NOTES:1.VALVE TO BE SUPPORTED BY GRAVEL, PROVIDE BLOCK SHIM AS REQUIRED2345677L304MODEL 5RC SERIESQUICK COUPLER VALVE NTS1.FINISH GRADE/ TOP OF MULCH2.QUICK-COUPLING VALVE3.VALVE BOX WITH COVER4.3-INCH MINIMUM DEPTH OF3/4-INCH WASHED GRAVEL5.PVC SCH 80 NIPPLE (LENGTH ASREQUIRED)6.BRICK (1 OF 2)7.PVC SCH 40 STREET ELL8.PVC SCH 40 TEE OR ELL9.PVC MAINLINE PIPE10.PVC SCH 40 ELL11.2" X 2" REDWOOD STAKE WITHSTAINLESS STEEL GEAR CLAMPS OREQUIVALENT SUPPORT SYSTEMNOTES:FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICALTO NOMINAL QUICK COUPLING VALVE INLET SIZE.1245671.EDGE OFCONCRETE ORTURF AREA2.NOZZLE ASINDICATED ONPLAN3.FINISH GRADE4.6"-12" POP-UPSPRAY BODY5.PVC LATERAL PIPE6.SWING PIPEASSEMBLY7.PVC SCH 80 TEEOR ELL38L304WITH SWING PIPESPRAY HEAD DETAIL NTS4"9L304THRUST BLOCK NTSNOTES:1.SIZE THRUST BLOCKS SHALL BE SPECIFIED ASSHOW IN THE TABLE.2.CONTROL WIRES SHALL NOT BE ENCASED INCONCRETE.3.ALL FITTINGS SHALL BE WRAPPED WITHPOLYETHYLENE TO PREVENT CONCRETE FROMADHERING TO PIPE, FITTINGS OR BOLTS.4.JOINTS AND BOLTS SHALL BE ACCESSIBLE FORREPAIRS.5.THRUST BLOCKS SHALL BE A MINIMUM OF 6"THICK.6.ONE 80 LBS. SACK OF CONCRETE SHALL COVER.6 FT.³PIPE SIZETEE AND PLUG90° BEND45° BEND1-1/2"2"2-1/2"3"4"6"8"10"14.93 FEET ²9.08 FEET ²5.25 FEET ²2.43 FEET ²1.48 FEET ²1.0 FEET ²0.69 FEET ²0.45 FEET ²0.63 FEET ²0.97 FEET ²1.41 FEET ²2.10 FEET ²3.45 FEET ²7.41 FEET ²12.83 FEET ²21.07 FEET ²11.44 FEET ²6.96 FEET ²4.02 FEET ²1.87 FEET ²1.14 FEET ²0.77 FEET ²0.53 FEET ²0.34 FEET ²1.BEARING SURFACE2.EXISTING OR MODIFIEDSOIL (SEE SPECIFICATIONFOR SOIL MODIFICATION)3.FLOW DIRECTION3112NOTES:1.SEE IRRIGATION LEGEND FOR MAINLINE AND LATERAL LINE PIPE SIZE AND TYPE.2.DIRECT BURIAL CONTROL WIRES SHALL BE INSTALLED IN SCH. 40 PVC ELECTRICAL CONDUIT IFREQUIRED.3.2-WIRE IRRIGATION WIRE SHALL BE INSTALLED IN SCH. 40 PVC ELECTRICAL CONDUIT.4.DETECTABLE LOCATOR TAPE SHALL BE LOCATED SIX INCHES (6") ABOVE THE ENTIRE MAINLINE RUN.24" MIN.6"2" IN PLANTING AREA3'0" UNDERNEATH PAVEMENT10L304IRRIGATION TRENCHING NTS1.FINISHED GRADE2.PAVEMENT3.NON-PRESSURIZEDLINE (LATERAL LINE)4.DETECTABLELOCATOR TAPE5.PRESSURIZED LINE(MAINLINE)6.DIRECT BURIALLOW VOLTAGECONTROL WIRES6543211" IN
PLANTING
AREA
NOTES:1.SEE IRRIGATION LEGEND FOR MAINLINE SIZE AND TYPE.2.ALL SLEEVES SHALL BE SCH. 40 PVC PIPE.3.ALL SLEEVES SHALL EXTEND 12" BEYOND THE EDGE OF PAVEMENT.4.END OF SLEEVES SHALL BE LOCATED WITH A WOODEN STAKE OR PVC PIPE. LOCATORS SHALL RUNCONTINUOUSLY FROM THE END OF THE SLEEVE TO FINISHED GRADE.2"-0"1.PAVEMENT2.BASE ROCK3.CLEAN BACKFILL, 95% RELATIVECOMPACTION UNDER PAVING ORPER CIVIL ENGINEERS PLANS4.CONTROL WIRES, SLEEVE UNDERPAVING. INSTALL ADJACENT TOPRESSURIZED MAINLINE. BUNDLESHALL BE NO MORE THAN 50%OF PIPE DIAMETER5.MAINLINE, SLEEVE UNDER PAVINGTO BE TWO TIMES THE DIAMETEROF THE PRESSURIZED MAINLINEPIPE6.NON-PRESSURIZED LINE, SLEEVEUNDER PAVING TO BE TWO TIMESTHE DIAMETER OF THE LATERALLINE11L304PIPE BENEATH PAVEMENT NTS65432112L304NETAFIM TECHLINE CV-MULTIPLE TREE RING NTS4 FTMF1.VALVE, FILTER,PRESSUREREGULATOR2.SUPPLY HEADERPVC OR BLANKTUBING3.TREE TRUNK4.MANUAL LINEFLUSHING VALVEMODEL: TLSOV5.EXHAUST HEADER6.TECHLINE® CVDRIP TUBING2456319/18/24 City Submittal1/17/25 Building Permit