HomeMy WebLinkAbout11 C301E ENLARGED UTILITY PLAN SITE PLAN PACKAGE 'E'ststwm wm wm wm wm wm wm wm wmstststststwmwmstststst8"8"st stwmwmssssstXXXXXXXXXXXXXXXXXXXXXXXXXss ss ss ss ss sswm
S89° 50' 17.87"E 319.323'S0° 05' 07.67"E 247.253'N89° 54' 57.64"E 367.842'L=165.817,R=275.000D=34.5476 S0° 04' 45.31"E 92.677'N0° 04' 44.70"W 23.483'L=119.794,R=215.000D=31.9241L=12.911, R=195.000=3.7937BP BP BP BP BP BP BPWV PHBUILDING #18APARTMENTTYPE A3,895 SFFFE = 4,854.50BUILDING #15APARTMENTTYPE C8,234 SFFFE = 4,855.20BUILDING #16
GARAGE
BUILDING #17
GARAGE
WS WS WS WSWSWSF F F F FFFFSSSSSS FFWSBP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BPBPBPPHPHBPBPBPGASGASGAS GASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASBPBPBPBPBPBPBPBPBPBP
BPBPBPBPBPBPBPBPBPBPBPBP BP BP BP BP BP BPBP BP BP BP BP BP BPDSTSTDSTDSTSTSTSTST ST ST STSTSTSTSTSTSTST STD10.00PUE60.00ROW10.00PUE10.00PUE30.00ROW30.00
ROW
FWSSTSTWSFABCDABCD1234512345COPYRIGHT GGLO. ALL RIGHTS RESERVED.ORIGINAL SHEET SIZE IS 24"x36"SHEET NO.SHEET TITLEGGLO PROJECT MANAGER:GGLO PRINCIPAL IN CHARGE:PROJECT NO.:OWNER APPROVAL:MARKDATEDESCRIPTIONISSUE INFORMATIONPROJECT:OWNER:PROJECT ADDRESS:OXBOW APARTMENTS4650 W GARFIELD STBOZEMAN, MT 59718OXBOW APARTMENTSPHASE IIOXBOW LAND HOLDING LLC1100 W IDAHO ST, SUITE 630BOISE, ID 837022023075®REVISIONSA10.18.2024FORMAL SITE DEVELOPMENTREVIEWMARKDATEDESCRIPTIONB12.18.2024SPR Rev. #1C02.07.2025SPR Rev. #2C301EENLARGED UTILITY PLANSITE PLAN PACKAGE 'E'1C301EENLARGED UTILITY PLAN0102040SCALE: 1" = 20'NORTH6" D.I. FIRE PROTECTION LINE.2" TYPE K COPPERDOMESTIC WATER SERVICE4" PVC SS SERVICE. CONNECTTO BUILDING. SEE DETAIL3/C404E. COORDINATE W/PLUMBING FOR CONNECTION.6" PVC SS SERVICE. CONNECTTO BUILDING. SEE DETAIL3/C404E. COORDINATE W/PLUMBING FOR CONNECTION.6" D.I. FIRE PROTECTION LINE..4" D.I. DOMESTIC WATER SERVICE.REDUCE TO 3" METER INSIDE BUILDING.EXISTING 8" PVC SANITARY SEWER MAINEXISTING 8" D.I. WATER MAIN STAFFORD AVENUE6" PVC SS SERVICE.CONNECT TO EXISTINGSEWER SERVICE STUB. SEEDETAIL 3/C404E.COORDINATE W/ PLUMBINGFOR CONNECTION.CONTRACTOR TO VERIFYLOCATION AND ELEVATIONREMOVE BLOW-OFF ASSEMBLY.6" D.I. FIRE PROTECTION LINE,CONNECT TO EXISTING STUB.NEW CLEANOUT.SEE DETAIL 10/C401E.NEW ELECTRICAL TRANSFORMER,PULL BOX AND BURIED SERVICELINE. COORDINATE WITH NWE FORNEW BUILDING SERVICES, TYP.REMOVE BLOW-OFF ASSEMBLY.CONNECT TO EXISTING 8"WATER MAIN STUB.CONTRACTOR TO VERIFYLOCATION & ELEVATIONNEW ELECTRICALMETERS, TYP.ALLEYNEW MECHANICALUNITS & ELECTRICALMETERS. TYP.NEW CLEANOUT.SEE DETAIL 10/C401E.NEW MECHANICALUNITS, TYP.ALLEYNEW ELECTRICAL TRANSFORMERSEE INFRASTRUCTUREREVIEW FOR FIRE LINEAND DOMESTIC WATERSERVICE LINE PROFILESEXISTING FIREHYDRANTELECTRICALSERVICE LOCATIONSSEE INFRASTRUCTUREREVIEW FOR FIRE LINEAND DOMESTIC WATERSERVICE LINE PROFILESBURIED GAS LINE ANDSERVICE TO PATIO AREA2C301EBUILDING TYPE A MECHANICAL ROOM3C301EBUILDING TYPE C MECHANICAL ROOM5.7710.81
MECHANICAL ROOM
SEE INFRASTRUCTURE
SUBMITTAL FOR WATER
LINE PROFILE 10.944.90MECHANICAL ROOM
SEE INFRASTRUCTURE
SUBMITTAL FOR WATER
LINE PROFILEPACKAGE D COMPLETED UNDER SEPARATE CONTRACTCCSTUB OUT OF BUILDING FORIRRIGATION DOWN STREAM OFMETER. PROVIDE BACKFLOWPREVENTER IN MECHANICAL ROOM.C