HomeMy WebLinkAbout028.01 - L 600 - Irrigation Notes & LegendsGENERAL IRRIGATION NOTES AND SPECIFICATIONS1.ALL VALVE BOXES TO BE STANDARD SIZE OR LARGER.2.IRRIGATION MAIN LINE TO BE 1" SCH 40 PVC PIPE.3.ALL TREES TO BE IRRIGATED THROUGH DEDICATED BUBBLERS. BUBBLERS TO BE EVENLYDISTRIBUTED AROUND BASE OF TREE WITH FOUR (4) EVENLY SPACED BUBBLER EMITTERS.4.TREES AND SHRUBS PLACED WITHIN PLANTING BEDS MAY UTILIZE DRIP IRRIGATION. DRIPIRRIGATION TO BE ADJUSTED PER REQUIREMENTS OF EACH INDIVIDUAL PLANT.5.ALL SHRUBS OUTSIDE OF DEDICATED PLANTING BEDS TO HAVE DEDICATED BUBBLERS.BUBBLERS TO BE EVENLY DISTRIBUTED AROUND BASE OF SHRUB WITH TWO (2) EVENLYSPACED BUBBLER EMITTERS.6.DRIP LINE TO BE COMPLETELY BURIED UNDER MULCH LAYER.7.ALL MIXED SHRUB AND PERENNIAL PLANTINGS TO BE IRRIGATED WITH DEDICATED DRIPTUBING. DRIP EMITTERS TO BE ADJUSTED PER REQUIREMENTS OF EACH INDIVIDUAL PLANT.EMITTERS PER PLANT TYPE:PERENNIALS- (1) 0.5 GPH EMITTERSHRUBS- (2) 1.0 GPH EMITTERSTREES- (4) 1.0 GPH EMITTERS***TREES UTILIZING DRIP IN PLANTING BEDS MAY NEED ADDITIONAL EMITTERS TO MEET WEEKLY WATERING REQUIREMENTS.8.SYSTEM SHALL UTILIZE WEATHER / MOISTURE MONITOR.9.BACKFLOW ASSEMBLY AND BLOWOUT ASSEMBLY SHALL BE LOCATED IN MECHANICALROOM OR APPROVED EXTERNAL GRADEBOX. IT IS THE RESPONSIBILITY OF THE LANDSCAPECONTRACTOR TO COORDINATE INSTALLATION PER LOCAL CODES AND ORDINANCES ASWELL AS WITH ARCHITECTURE AND ALL OTHER TRADES.10.POWER SOURCE FOR IRRIGATION CONTROLLER TO BE COORDINATED WITH ELECTRICALENGINEER, ELECTRICAL CONTRACTOR AND LANDSCAPE CONTRACTOR.11.DO NOT INSTALL IRRIGATION SYSTEM WHEN OBVIOUS OBSTRUCTIONS OR GRADE CHANGESARE PRESENT.12.ALL INFORMATION TO BE FIELD-VERIFIED BY CONTRACTOR PRIOR TO INSTALLATION.13.THE CONTRACTOR SHALL MAINTAIN AN ACCURATE & CURRENT 'AS-BUILT' IRRIGATION PLANON SITE AT ALL TIMES.14. IF NOT WITHIN LIMITS OPERATING PRESSURE, CONTRACTOR MUST CONTACT LANDSCAPEARCHITECT.15.IRRIGATION SLEEVING TO BE PROVIDED BY CIVIL CONTRACTOR/GC; SET SLEEVES UNDERROADS PER PLAN COORDINATE WITH LANDSCAPE/IRRIGATION INSTALLER PRIOR TOPOURING ROADS OR CONCRETE.16.ALL BUILDING LANDSCAPE IRRIGATION TO BE COORDINATED WITH LANDSCAPECONTRACTOR, G.C., MEP, ARCH., AND PLUMBER.---CONNECTION POINT TO BE DETERMINED BY OTHERS, GRAPHICALLY SHOWN FORINTENT ONLY---PROVIDE BACKFLOW PREVENTION IN WET MECH ROOM ABOVE FLOOR DRAIN ANDSTUB OUT OF THE BUILDING DURING CONSTRUCTION OF HOME.17.FINAL IRRIGATION AND PLUMBING EQUIPMENT SUBJECT TO CHANGE.18.IRRIGATION SLEEVING TO BE PROVIDED BY CIVIL CONTRACTOR/GC; SET SLEEVES UNDERROADS PER PLAN COORDINATE WITH LANDSCAPE/IRRIGATION INSTALLER PRIOR TOPOURING ROADS OR CONCRETE AND SETTING BOULDER RETAINING WALLS19.SEE IRRIGATION PLAN FOR MORE INFORMATION SHEETS L6.00-L7.01SYMBOLSIZEDETAILDESCRIPTIONIRRIGATION LEGENDBACKFLOW PREVENTERWATTS 009 RPZ OR EQUIVALENT1.0"2, L700IRRIGATION CONTROLLERHUNTER ICC2 OR EQUIVALENT1, L700WEATHER STATIONHUNTER MWS-FR OR SIMILAR3, L700CONNECTION POINTDRIP CONTROL VALVE (PRESSUREREGULATED)HUNTER PCZ-101-40, ICZ-101-40 DRIPCONTROL OR SIMILAR10-12,L7001.0" PVC MAINLINE, SCH 40 PVC5, L7001.0" LATERAL LINE, SCH 40 PVC OR PE***5, L700DRIP LINE, SOFT WALL DRIP TUBING12-13, L700IRRIGATION SLEEVE, 4" MIN. SCH 40 PVC6, L700VALVE SCHEDULEIRR MAINIRRIRRDDQTY11115SEE PLANSEE PLANSEE PLANSEE PLANSEE PLAN8, L7004, L70021QUICK COUPLER FOR BLOW OUT USERAINBIRD HQ44-RC OR SIMILARISOLATION VALVE/GATE VALVE DRAINNIBCO T-113 BRONZE GATE VALVE ORSIMILARTREE DRIP LINE, SOFT WALL DRIPTUBING12-13, l700SEE PLANDDDZONE #/TYPESIZEGPMBFCPCW1.0"ZONE TYPESD= DRIP IRRIGATIONDT = DRIP TREE IRRIGATIONNOTE: ***PVC 1" LATERAL LINES CREATE SLIGHTLY MORE PSI LOSS THAN 1" PELATERAL LINES, PVC OR POLY ARE ACCEPTABLE. SEE PRESSURE LOST CHARTSWATERCOURSE RECLAIMATION SEEDING WILL NOT BE IRRIGATED.1.0"1.0"1.0"1.0"1.0"0.75"0.75"H2ODAYGPMPROPOSED IRRIGATION SCHEDULE1.370.470.730.71(MON)DURATIONMINUTES60906060H2OINITIAL GPD82.242.343.842H2OEST. GPD41212121ZONE1D2DT3D4DTOTAL DAILYH2O INITIAL210.3 GALTOTAL DAILYH2O EST.105 GAL02(TUES)000N/A0 GAL0 GALNOTE: DRIP IRRIGATION IS ALLOWED TO BE USED ANY DAY OF THE WEEK AS NEEDED PER CITY OFBOZEMAN WEBSITE:https://www.bozeman.net/departments/utilities/water-conservation/permanent-watering-restrictions. IFIT IS THE DUTY OF THE OWNER AND MAINTENANCE CONTRACTOR TO CONFORM TO ALL CITYOF BOZEMAN WATERING RESTRICTIONS UPON PROJECT OCCUPANCY.3(WED)4(THUR)5(FRI)6(SAT)7(SUN)1.370.470.730.76090606082.242.343.842412121211D2DT3D4D210.3 GAL105 GAL0000N/A0 GAL0 GAL1.370.470.730.76090606082.242.343.842412121211D2DT3D4D210.3 GAL105 GAL0000N/A0 GAL0 GAL1.370.470.730.76090606082.242.343.842412121211D2DT3D4D210.3 GAL105 GALANNUAL WATER USE BASED ON AREA USING PROPOSED SCHEDULE- ESTABLISHEDWATERING WINDOW USED: MAY-SEPTEMBER(5 MONTHS/ 22 WEEKS)PER C.O.B.WATER CONSERVATION WEBSITE-TOTAL GALLONS USED @22 WEEKS= 9,240 GAL-AREA OF LANDSCAPE = 1,322 FT²WATER USE = 6.99 GAL/FT²Irrigation Notes &LegendsL 600SHEET NUMBERPROJECT CODEPROJECT ADDRESSARCHITECT RETAINS COPYRIGHT TO THESE DRAWINGS.DRAWINGS ARE ONLY FOR USE FOR PROJECT NAMED ONDRAWING SHEET AND MAY NOT BE REPRODUCED OR USEDFOR OTHER PURPOSES WITHOUT WRITTEN PERMISSIONFROM ARCHITECT.PRELIMINARYNOT FORCONSTRUCTIONDesign 5111 N TracyBOZEMAN, MT 59715SHEET NAMEPROJECT NAMEDRAWING REVISIONSDRAWING ISSUE DATEDRAWING ISSUED FORPHONE: (406) 578-4873BHMBOUTIQUEHOTELMENDENHALL302 East Mendenhall St.Bozeman, Montana,59715SITE PLANAPPLICATION10-09-2024Site Plan Resubmittal 111