HomeMy WebLinkAbout026.02 - L 504 - Landscape Details3L5043/4" = 1'-0"Timber Framed Bocce Court - Section6"12"5"FILTER FABRIC6" MIN. COMPACTED 34"MINUS WASHEDAGGREGATE BASEMATERIAL6x12 PRESSURETREATED TIMBER#4 REBAR 24" LONGCOMPACTEDSUBGRADEPAVEMENTPER PLAN(3) 4" PERFORATED DRAIN PIPEWRAPPED IN LANDSCAPE FILTERFABRIC. DRAIN PIPE TO RUNLENGTHWISE DOWN COURT, SPACEEACH PIPE EVENLY APART ANDDAYLIGHT DOWNSLOPE3" DEPTH - COMPACTED 14" MINUSDECOMPOSED GRANITE5'-6"SEE PLANEQUAL 6"DECOMPOSED GRANITE6X12 PRESSURETREATED TIMBER4" PERF DRAINTILEDRAIN TO DAYLIGHTTIMBER SPIKE. CENTERSPIKE ON TIMBEREQ.EQ.EQ.FIELD SPLICE4L5043/16" = 1'-0"Bocce Ball Court - PlanEQUAL PLANFRONT ELEVATIONSECTION A1L504NTSCustom Steel & Boulder Fire Pit2'APPROX. 4'-6"4'APPROX. 6'1'-9"ABOULDERFLATWILLOW FIRE PIT BOULDERMONTANA HARDSCAPES406-579-6554MONTANAHARDSCAPES.COMSTEEL 38" THICK 2'X4' STEEL FIREPITBURNERSELECTION TBDMIN. 350K BTU.NOTES:1.DRAWING FOR SCHEMATIC INTENT. FABRICATOR TOPROVIDE SHOP DRAWING TO LANDSCAPEARCHITECT FOR APPROVAL. FINAL DESIGN TBD.2.CONTRACTOR TO PROVIDE CONTROL SWITCH ANDGAS SAFETY VALVE ON FIREPIT.3.VERIFY GAS LINE SUPPLY AND SIZING WITH MEPGASGAS1'-8"FLATWILLOW ACCENT BOULDERSCRIBED TO FIT FLUSH WITHSTEELCUSTOM 9"X4' MONTANAFIREPITS PAN & BURNERINSERTANGLE IRON SUPPORT FORBURNER PAN @ 18" O.C.INCLUDE LOCKABLE GAS LEVERALONG GAS LINE, HIDDEN IN FIREPITGAS CONTROL VALVE KEY1"-3" REVEAL OF BOULDERABOVE STEEL FIREPITACCENT BOULDER SCRIBED TO FITFLUSH WITH STEELLAVA PEBBLE FIRE MEDIAANGLE IRON SUPPORT FOR BURNERPAN @ 18" O.C.BOULDER TO BE CUT TOSIT LEVEL ON FOUNDATION SLAB1" NATURAL GAS LINE INSTALLED PER LOCALCODES AND ORDINANCES. VERIFY GAS LINEAND SIZE WITH MEP.PAVING PER PLAN1" SCH 40 PVC ELECTRICAL CONDUIT, 120VPOWER SUPPLY PER MANUFACTURER'SSPECIFICATIONS6" FOUNDATION SLAB. USE BOULDER SIZE TODETERMINE SLAB SIZE.MIN 3"Olympic Fire Table - Montana Fire PitsNO SCALE L50421'-4"TREE STYLE BURNER350K BTUMANUAL CONTROL SWITCH IGNITIONOLYMPIC FIRE TABLEMONTANA FIREPITS855-311-4855MONTANAFIREPITS.COMLAVA PEBBLES FIRE MEDIA1" NATURAL GAS LINEINSTALLED PER LOCAL CODESAND ORDINANCES. VERIFY GASLINE CONNECTION AND SIZINGWITH MEP.1" SCH 40 PVC ELECTRICAL CONDUIT, 120VPOWER SUPPLY PER MANUFACTURER'SSPECIFICATIONSSEE L001 FOR FINISH4'2'-8"PAVING PER PLANLandscapeDetailsL 504design5la.com406.587.4873dateissuedrawn by:checked by:filename:z:\brick capital block 104\autocad\01_sheets\block104-south_standarddetails.dwg Bozeman Yards South Bozeman, Montana AVD TMS/AVD NO T F O R C O N S T R U C T I O N1/29/25SPR RC2