HomeMy WebLinkAbout006--A1.1 Architectural Site PlanUPUPDNDNNORTH TRACY AVENUE14' ALLEYS 88°31'26" E 150.01'S 01°04'35" W 56.98'N 88°30'05" W 150.01'N 01°04'12" E 56.92'LOT 15REMAINDER OF LOT 16NORTH 7' OF LOT 168543 SFDOC.2776345479447944 7 9 4 47944794479447944794479447944 79 4A.REFER TO LANDSCAPE DRAWINGS FOR ALL PLANTER AND LANDSCAPED AREAS.B.REFER TO CIVIL DRAWINGS FOR GRADING, DRAINAGE AND ADDITIONAL TOPOGRAPHIC INFORMATION.C.PROVIDE POSITIVE DRAINAGE AWAY FROM ALL STRUCTURES 2% MINIMUM FOR THE FIRST 10 FEET.D.AN APPROVED GRADING & DRAINAGE PLAN SHALL BE KEPT ON SITE AT ALL TIMES. DEVIATIONS FROM THE PLAN MUST BE PRECEDED BY AN APPROVED REVISION.E.REFER TO CIVIL FOR UTILITY INFORMATION. CONTRACTOR TO PROVIDE SOIL COMPACTION TEST RESULTS AS REQUIRED TO THE CITY ENGINEER'S OFFICE.F.COORDINATE WITH ALL UTILITY COMPANIES FOR FINAL LOCATION OF METERS, DEVICES, AND ROUTING. CONTRACTOR TO PROVIDE ALL REQUIRED MATERIAL AND LABOR FOR INSTALLATION OF ALL REQUIRED UTILITIES.G.MAINTAIN A MINIMUM DISTURBANCE OF SITE DURING CONSTRUCTION.H.EXCESS FILL DIRT (IF ANY) TO BE HAULED AWAY OR DISPOSED OF PER THE OWNER'S REQUEST.I.VERIFY WITH THE OWNER THE DEMOLITION OR RELOCATION OF ALL EXISTING LANDSCAPE MATERIALS AND SITE ITEMS PRIOR TO COMMENCEMENT OF NEW CONSTRUCTION.J.CONTRACTOR SHALL FIELD VERIFY ALL SITE ITEMS AND THE COORDINATION OF NEW CONSTRUCTION WITH ZONING SETBACK REQUIREMENTS. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES.K.VERIFY ALL GRADES IN FIELD.L.SEE ELECTRICAL SHEETS FOR SWITCHING OF EXTERIOR ELECTRICAL.M.SUBGRADE TO BE COMPACTED TO 95% OF MAXIMUM DENSITY WITH CONCRETE SLAB OVER A.B.C. AS SPECIFIED ON THE STRUCTURAL DRAWINGS.N.WATERPROOF ALL ABOVE-GROUND PLANTERS AND RETAINING WALLS.O.ALL MECHANICAL EQUIPMENT SHALL BE SCREENED, WHERE APPLICABLE, A MINIMUM OF 1'-0" HIGHER THAN THE HIGHEST PORTION OF THE EQUIPMENT, AND SHALL MATCH THE ADJACENT BUILDING MATERIAL.P.PROVIDE 36" GUARDRAILS AT ALL CHANGE IN ELEVATIONS THAT ARE GREATER THAN 30" (R312).Q.NEW CONSTRCUTION SHALL DIRECT STORMWATER DRAINAGE TO ON SITE RETENTION.R.A MINIMUM OF 6" MUST BE PROVIDED FROM FINISH GRADE TO BOTTOM OF WOOD SIDING. PAINT FOUNDATIONS TO MATCH SIDING AND COVER ALL EXPOSED RIGID INSULATION WITH BRAKE METAL TO MATCH SIDING OR WINDOW TRIM.PROJECT DATUM:+101'-2 1/4" = + 4796.0UNIT 1 PARKING 1/2PARKING 3UNIT 1 GARAGEUNDER SEPARATE PERMITUNIT 2 PARKING 1/2UNIT 2 GARAGEUNDER SEPARATE PERMITUNIT 1 OPEN SPACE25'-2" X 28'-4"AREA: 715SF UNIT 2 OPEN SPACE25'-2" X 28'-5"AREA: 716SFPARKING 4PARKING 3PARKING 426.133.32.5% 2% MIN2% MIN2.5%PROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINE SETBACKSETBACKSETBACK23.12% MINB.S.L.5' - 0"B.S.L.20' - 0"SETBACKB.S.L.5' - 0"REAR YARD AREA:4,000SFUNIT 1UNIT 225' - 2 1/2"28' - 5 3/4"28' - 4 3/4"25' - 2 1/2"SE/TWWSGGGGGE/TE/T1' - 0"3' - 0"GGG10' - 0"E/TE/TE/TWWWWW1' - 0"SS15' - 0"10'-0" MIN.SSENTRY SETBACKENTRYENTRYSIDEWALKSIDEWALKSIDEWALKSIDEWALK15' - 0"25' - 0"FF: +4796.5'FF: +4796.5'FF: +4795.0'5' - 0"1TWO+ BEDROOM DWELLING 2 PARKING SPACES2 UNITS4 TOTAL SPACE REQUIREDBOZEMAN MUNICODE 2020 -TABLE 38.540.050-1UNIT 12+BEDROOM4 PARKING SPACESUNIT 22+BEDROOM4 PARKING SPACESTOTAL PARKING REQUIRED:8 PARKING SPACESPARKING CALCULATIONS -PROVIDED10% OF LIVING SPACEBOZEMAN MUNICODE 2020 -SEC 38.360.250TOWNHOUSE AND ROWHOUSE DWELLINGSOPEN SPACE CALCULATIONS -PER UNITLIVING SPACE = 4,349 SF OPEN SPACE REQUIREMENT 10% TOTAL OPEN SPACE REQUIRED = 434.9 SFTOTAL OPEN SPACE PROVIDED = 1,431 SFBOZEMAN MUNICODE 2020 -SEC 38.320FORM AND INTENSITY STANDARDSTABLE 38.320.030CZONING:R-2MAX LOT COVERAGE: 40%LOT SIZE:8,543 SFLOT COVERAGE: 50% MAX (rowhouse) 4,271.5PROPOSED LOT COVERAGE:3,859.0 SF45%COMPLIESFAR:.75:1LOT SIZE:8,543 SFMAX SF UNDER ROOF: 6407.5TOTAL --5,993 PROVIDED.32:1MAX BUILDING HEIGHT:9:12 SLOPE40 FEET BUILDING HEIGHT:30'-10"COMPLIESSETBACKS:SEE SITE PLANACCESSORY BUILDINGREAR LOT AREA:4,000 SFALLOWED AREA 40%:1,600 SFACCESSORY BUILDING FOOTPRINT:1,164 SF1NORTH2345678910FEDCBAGH1PROJECT NO:DATE:23006MAY 15, 2024All reports, drawings, specifications, computer files, field data, notes, other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect, LocalElementArchitects, LLC. The Architect shall retain all common law, statutory and other reserved rights, including copyright thereto. The use of this drawing shall be restricted to the original site for which it was prepared and publication thereof is expressly limited to such use. Reuse, reproduction or publication by any method is prohibited without written consent from LocalElementArchitects, LLC. NCOANOT FOR CONSTRUCTION11/12/2024 3:27:19 PM C:\Users\chris\OneDrive\Documents\23001--411 N.Tracy_CENTRAL_chrisTMMND.rvtTRACY ROWHOUSES411 N. TRACY AVE.BOZEMAN, MT 59718A1.1SITE PLANGENERAL SITE PLAN NOTESFINISH FLOOR LEGENDSCALE: 1/8" = 1'-0"1SITE PLANUNIT 1 AREA CALCULATIONSUNIT 1 RESIDENCEU-1 COVERED PATIO 172 SFU-1 COVERED ENTRY 120 SFCOVERED PATIO 292 SFUNIT 1 MAIN FLOOR 1,107 SFUNIT 1 SECOND FLOOR 1,067 SFUNIT 1 BASEMENT 186 SFLIVABLE 2,359 SFUNIT 1 UNFINISHED BASEMENT 889 SFUNFINISHED BASEMENT 889 SFUNIT 1 RESIDENCE 3,539 SFUNIT 2 AREA CALCULATIONSUNIT 2 RESIDENCEU-2 COVERED ENTRY 59 SFU-2 COVERED PATIO 128 SFCOVERED PATIO 187 SFUNIT 2 MAIN FLOOR 1,109 SFUNIT 2 SECOND FLOOR 1,067 SFUNIT 2 BASEMENT 186 SFLIVABLE 2,361 SFUNIT 2 UNFINISHED BASEMENT 919 SFUNFINISHED BASEMENT 919 SFUNIT 2 RESIDENCE 3,467 SF23.1 EXTERIOR MECHANICAL A/C UNIT ON 4" CONC. PAD26.1 ELECTRICAL SERVICE ENTRANCE AND METER - FINALSIZE/DESIGN/LOCATION PER CONTRACTOR33.3 GAS METER LOCATIONKEYNOTESPARKING NOTESFORM & INTENSITY STANDARDSOPEN SPACE CALCSUNIT 1 AREA CALCULATIONS...UNIT 1 ACCESSORYGARAGE 1 ACCESSORY 582 SFGARAGE/MECH.: 1 582 SFUNIT 1 ACCESSORY 582 SFUNIT 2 AREA CALCULATIONS...UNIT 2 ACCESSORYGARAGE 2 ACCESSORY 582 SFGARAGE/MECH.: 1 582 SFUNIT 2 ACCESSORY 582 SFLOT COVERAGEUNIT 1 MAIN FLOOR 1,107 SFUNIT 2 MAIN FLOOR 1,109 SFGARAGE 1 ACCESSORY 582 SFGARAGE 2 ACCESSORY 582 SFU-1 COVERED PATIO 172 SFU-1 COVERED ENTRY 120 SFU-2 COVERED ENTRY 59 SFU-2 COVERED PATIO 128 SFPROJECT DATUM 3,859 SFREVISIONSNO. DATE DESCRIPTION1 11/11/2024 NCOA REVISION 11