044 - L 700 - Irrigation Details
NOTE:MOUNT CONTROLLER LCD SCREEN AT EE LEVEL,CONTROLLER SHALL BE HARD-WIRED TOGROUNDED 110 VAC POWER SOURCELEGEND:IRRIGATION CONTROLLER ƺ12C-800-PLƻ PER PLANIRRIGATION CONTROL WIRE IN CONDUITSIE AND TPE PER LOCAL CODESELECTRICAL SUPPL CONDUITCONNECT TO POWER SOURCE, -BO INSIDECONTROLLERAD ACENT SURFACE TO MOUNT CONTROLLER PER PLAN13ͲʼͲ1234123441L700NTSIÈÈ¿½·Ê¿ÅÄ CÅÄÊÈÅÂÂ»È - HËÄÊ»È ICC2 ÅÈ EÇ˿̷»ÄÊƺ1ƻNOTES1.1Ͳ BACKFLOW ASSEMBL, PER LOCAL CODES AND ORDINANCES2.INTERIOR PRESSURE VACUUM BREAKERS TO BE INSTALLED IN MECH. ROOMSWITH SANITAR FLOOR DRAINAGE BELOW, IN ACCESSIBLE LOCATION.3.LANDSCAPE CONTRACTOR, ARCHITECT, AND MEP TO COORDINATEPLACEMENT AND STUB OUT LOCATION BEFORE HOME COMPLETION.MANUAL BRASS SHUTOFFBALL VALVEMANUAL BRASS SHUTOFF BALL VALVE2L700NTSB·¹Á¼ÂÅÍ PȻ̻ÄÊ»È ƺIÄʻȿÅÈ, TÏÆ.ƻWATERDRAINWATER SOURCE INIRRIGATION SUPPLOUT, PROVIDE STUBOUT OF BUILDINGMODEL SHOWN: WATTS 00ˀ RP ASSEMBLTEST COCK, TP.NOTE:FOR MOST ACCURATE TEMPERATURESENSING, ROTATE THE MWS SO THAT THETHERMOSTAT PORTION POINTS SOUTH.THE MWS IS DESIGNED TO MOUNT ON APOST OF 2Ͳ PIPE, AN COMBINATION OFPIPE AND FITTINGS MA BE USED.2Ͳ PIPEMOUNT TO POST OR WALLWITH CONDUIT CLAMPSMODEL MWS-FR OR SIMILAROPTIMUM MOUNTINGHEIGHT ʽͱ ABOVE GRADERUN LEAD WIRESTO CONTROLLER3L700NTSM¿Ä¿ W»·Ê¾»È SÊ·Ê¿ÅÄ - HËÄÊ»È ÅÈ EÇ˿̷»ÄÊNOTE:FINISH GRADES AT VALVE BOES MUST BE AT A LEVEL SUCH THATTHE ESTABLISHED TURF OR MULCH SURFACE WILL FLUSH WITH THETOP OF THE BO.QUICK COUPLING VALVE:RAINBIRD HQ44-RC OR EQUIVALENTʽͲ ROUND VALVE BO WITHLOCKING LID3 INCH MINIMUM DEPTH OF34Ͳ WASHED GRAVELBRICK ƺ1 OF 2ƻPVC SCH. 80 NIPPLEPVC 11 TT COUPLING LASCOG132212 SWING OINTPVC OR POL MAINLINE PIPEPER PLAN3ʽͲ ʶ4 REBAR WITH STAINLESSSTEEL GEAR CLAMPSFINISH GRADE.4L700NTSQË¿¹Á CÅËÆÂ»È18Ͳ12Ͳ18Ͳ12Ͳ18Ͳ18ͲFINISH GRADELATERALLATERALMAIN LINEBEDDINGLOW VOLTAGE WIRELOW VOLTAGE WIRESECTIONSPLANSSNAKE ALLLATERAL PIPEIN TRENCHTAPE AND BUNDLE ALL WIRING AT 10ͱINTERVALS. USE ʽͲ WIDE MARKING TAPE ʽͲABOVE ALL DIRECT BURIAL WIRING. ALLSPLICES SHALL BE MADE IN VALVE BOESAND LOCATED ON AS-BUILT PLANS.ALL 120V. WIRING SHALL BE IN CONDUIT WITHMARKER TAPE AS ABOVE. ALL WIRING UNDERPAVEMENT AND THROUGH SLEEVES SHALL BEIN CONDUIT.TIE A LOOSE 20Ͳ LOOP IN WIRING AT ALLCHANGES IN DIRECTION GREATER THAN 30DEGREES. UNTIE ALL LOOPS AFTER MAKINGCONNECTIONSFINISH GRADEMARKING TAPETIESLOOPDIRECT BURSECTIONCONDUITSECTIONDIRECT BUR PLANCONDUIT PLANʼL700NTSTȻĹ¾¿Ä½ FINISH GRADESCH. 40 PVC SLEEVE - 4Ͳ MIN. OR 2 THE O.D.OF THE IRRIGATION PIPINGWRAP 12 GAUGE WIRE AROUND EACH ENDOF THE SLEEVE AND ETEND TO THESURFACEWASHED AND GRADED MORTARSAND BACKFILL IN ROCK SOIL.PAVEMENT EDGENOTE:1.CAP SLEEVES UNTIL USE.2.4Ͳ MIN. HORIONTAL SEPARATION REQUIRED BETWEEN SLEEVESIN THE SAME TRENCH.3.IRRIGATION PIPE AND CONTROL WIRES SHALL BE SLEEVEDSEPARATEL.4.SOIL AROUND SLEEVE BACKFILLED AND COMPACTED TO THESAME DENSIT AS THE SURROUNDING SOIL.DEPTH PER TRENCHING DETAILʽL700NTSIÈÈ¿½·Ê¿ÅÄ S»»Ì»EQ.EQ.IRRIGATION CONTROLVALVE BOPROVIDE EQUAL SPACINGBETWEEN BOESEDGE OF PAVEMENTALIGN BOES PARALLELTO THE EDGE OFPAVEMENTPLACE BOES A MINIMUMOF ONE ƺ1ƻ FOOT FROMEDGE OF PAVEMENTNOTE:GROUP SIMILAR BO TPES AND SIES TOGETHER, I.E. PLACERECTANGULAR OR ROUND BOES TOGETHER.1ͱ MIN.7L700NTSV·ÂÌ» BÅÎ L·ÏÅËÊNIBCO T-113 BRONE GATE VALVEOR EQUIVALENTSCH 40 MALE ADAPTORFINISH GRADE10Ͳ VALVE BO WƭLOCKING LIDSCH 40 PVC MAIN LINENOTE:FINISH GRADES AT VALVE BOES MUST BE AT A LEVEL SUCH THATTHE ESTABLISHED TURF OR MULCH SURFACE WILL FLUSH WITH THETOP OF THE BO.8L700NTSIÉÅ·ʿÅÄ V·ÂÌ»STANDARD 10Ͳ ROUND VALVE BOFINISH GRADE -SEE NOTE18-24Ͳ COILED WIREDBRƭDB CONNECTORS ƺ2ƻBRICK SUPPORTS ƺ3ƻSCH 80 T.O.E. NIPPLEMAIN LINE PIPE & FITTINGS3ƭ4Ͳ MINUS WASHED GRAVELDRIP ONE KITLATERAL PIPE AND FITTINGSPVC SLIP UNIONSNOTE:FINISH GRADES AT VALVE BOES MUST BE AT A LEVEL SUCH THATTHE ESTABLISHED TURF OR MULCH SURFACE WILL FLUSH WITHTHE TOP OF THE BO. DRIP VALVE REGULATED ʤ 2ʼ-40 PSIˀL700NTSIÈÈ¿½·Ê¿ÅÄ CÅÄÊÈÅ V·ÂÌ» - DÈ¿Æ S¿Ä½Â» V·ÂÌ»NOTES:- STANDARD BO TO ACCOMMODATE 4 VALVES- VALVE BANKS TO BE CONSTRUCTED TO LOCAL CODES AND STANDARDS.- LATERALS MA BE PE PIPE WITH SCH. 80 FITTINGS FIRML SECURED WITH OETIKER CLAMPS- IF PE PIPE IS USED FOR LATERAL LINES 2 OETIKER CLAMPS TO BE USEDAT EACH VALVE OUTLET CLAMPED AT MIRRORED ANGLES TO INSURE SECURE GRIP, SEE OETIKER CONNECTION DETAILS S T SCH. 40 TEETO MAINLINE BELOWSTANDARD VALVE BOSCH 80 THREADED NIPPLEWITH TEFLON TAPES T COUPLER WITH TEFLONTAPE AND PVC SOLVENTLATERAL LINE10L700NTSIÈÈ¿½·Ê¿ÅÄ V·ÂÌ» B·ÄÁ L·ÏÅËÊ, TÏÆ.SCH. 80 THREAD TO BARB ADAPTERTHREADED END TO BE TEFLON WRAPPEDOETIKERS ƺ2ƻ CLAMPED ON OPPOSING SIDESPOL PIPE LATERAL IRRIGATION LINEƺ1Ͳ TP.ƻOETIKERS ƺ2ƻ CLAMPED ON OPPOSING SIDES11L700NTSPÅÂϻʾÏ»Ļ L·Ê»È·Â L¿Ä» ·Ê V·ÂÌ» CÅÄÄ»¹Ê¿ÅÄ ƺO»Ê¿Á»È ¹ÅÄÄ»¹Ê¿ÅÄÉƻIÈÈ¿½·Ê¿ÅÄ D»Ê·¿ÂÉL 700© 2021 Lake|Flato Architects, Inc.3 1 1 T H I R D S T R E E TS A N A N T O N I O, T E X A S 7 8 2 0 5P 2 1 0. 2 2 7. 3 3 3 5 F 2 1 0. 2 2 4. 9 5 1 5w w w . l a k e f l a t o . c o mSET ISSUE DATESDATEISSUEPROJ. ARCHITECTDRAWN BY:L|F PROJ. NO.NEST PARTNERS113 E. OAK STREET 4BBOZEMAN, MT 5971504/22/22100% DESIGN DEVELOPMENT04/10/2350% CONSTRUCTION DOCUMENTS05/08/2375% CONSTRUCTION DOCUMENTS06/16/23100% CONSTRUCTION DOCUMENTSTHIS SQUARE APEARS 1/2"x1/2"ON FULL SIZE SHEETSCIVIL: TD&H ENGINEERING234 E. BABCOCK, SUITE 3BOZEMAN, MT 59715LANDSCAPE: DESIGN 5111 N. TRACY ST.BOZEMAN, MT 59715STRUCTURAL: IMEG108 WEST BABCOCK STBOZEMAN, MT 59715MEP: ENERGY12042 STADIUM DRIVE, SUITE 2BOZEMAN, MT 59715BUILDING KEYBCD11/01/23100% SCHEMATIC DESIGN - A01/26/24100% DESIGN DEVELOPMENT - ABCDE05/10/24100% CONSTRUCTION DOCUMENTS-PHASE 1Autodesk Docs://Nest Bozeman/Nest Bozeman–LFA–Arch–Main–R22.rvt 4/17/2024 3:02:51 PM100% CONSTRUCTIONDOCUMENTS - PHASE 2DEC 06, 202421043GOTSWALLACEWORKS801 N. WALLACE AVEBOZEMAN, MTEA07/17/2450% CONSTRUCTION DOCS - PHASE 208/02/2490% CONSTRUCTION DOCS - PHASE 208/23/24100% CONSTRUCTION DOCS - PHASE 21TBDADDENDUM #01 A044