HomeMy WebLinkAbout018 - Appendix M.2 - GL-2_Viewrail Glass Guardrail1
1
2
2
A A
B B
DRAWN BY:DATE:SIZE:SCALE:REV:
SYSTEM / PRODUCT:
ELE 6/18/2019 A 1/10
GLASS - BASE RAIL SHOE SYSTEM
SHEET NAME:OVERVIEW
1
1
2
2
A A
B B
DRAWN BY:DATE:SIZE:SCALE:REV:
SYSTEM / PRODUCT:
ELE 6/18/2019 A 1/10
GLASS - BASE RAIL SHOE SYSTEM
SHEET NAME:COMPONENTS
12'-0" MAXIMUM LENGTH PER PIECE
TILT LOCK
SUPPLIED AS ASSEMBLED UNIT
BASE RAIL
EXTRUDED ALUMINUM
SUPPLIED AS 1 UNIT
SOLD IN 12' - 8' - 4' PIECES
COSMETIC COVER
ALUMINUM EXTRUSION
COSMETIC COVER
4 15/16
2 7/8
1 3/16
1
1
2
2
A A
B B
DRAWN BY:DATE:SIZE:SCALE:REV:
SYSTEM / PRODUCT:
ELE 6/18/2019 A 1/15
GLASS - BASE RAIL SHOE SYSTEM
SHEET NAME:SYSTEM SPECIFICATIONS
GENERAL NOTES:
1.GLASS THICKNESS IS 12" OR 12MM, AND MUST BE TEMPERED OR LAMINATED SAFETY GLASS.
2.SPECIFICATIONS ARE FOR COMPONENTS ONLY. FASTENING THE BASE CHANNEL TO THE SUPPORT
STRUCTURE IS A SITE CONDITION AND THE INSTALLERS MUST ENSURE THAT THE FASTENERS ARE
ADEQUATE TO RESIST THE DESIGN LOADS.
3.THE MATERIAL TO WHICH THE GLASS SUPPORTS ARE BEING FASTENED MUST ADEQUATELY RESIST THE
DESIGN LOADS.
4.TILT LOCK CLIPS INSTALLED NO GREATER THAN 10" FROM END OF CHANNEL.
5.TILT LOCK CLIPS INSTALLED NO GREATER THAN 15" APART.
TRIPLE STACKED 2X8 (OR GREATER)
MINIMUM MOUNTING CONDITONS REQUIRED
SURFACE MOUNT SYSTEM TYPE INSTALLATIONS
DOUBLE STACKED LVL 4" THICK (MINIMUM)CONCRETE (4,000 PSI)
NON-COMRESSABLE FLOORING MATERIAL
NON-COMRESSABLE FLOORING MATERIAL
NON-COMRESSABLE FLOORING MATERIAL
RECCOMENDED FASTENER
WOOD
CONCRETE
38 X 5" SPAX POWER LAG
HEX WASHER DRIVE
CONCRETE WEDGE ANCHOR
3/8 x 3 1/2"
FASTENING LOCATIONS
PRE-DRILLED
48" MAXIMUM GLASS PANEL WIDTH
12" TYP
FASTENER
SPACING
MAX
10"
MAX
15"
TILE LOCK SPACING REQUIREMENTS
1/2" MINIMUM
GLASS
THICKNESS
TEMPERED
OR
LAMINATED
SAFETY
GLASS
42"
MAXIMUM
SYSTEM
HEIGHT