HomeMy WebLinkAbout035 Sht S2 LayoutStormTech888-892-2694 | WWW.STORMTECH.COM®Chamber System4640 TRUEMAN BLVDHILLIARD, OH 430261-800-733-7473DATE: DRAWN: EUPROJECT #: CHECKED: N/ATHIS DRAWING HAS BEEN PREPARED BASED ON INFORMATION PROVIDED TO ADS UNDER THE DIRECTION OF THE SITE DESIGN ENGINEER OR OTHER PROJECT REPRESENTATIVE. THE SITE DESIGN ENGINEER SHALL REVIEW THIS DRAWING PRIOR TO CONSTRUCTION. IT IS THE ULTIMATERESPONSIBILITY OF THE SITE DESIGN ENGINEER TO ENSURE THAT THE PRODUCT(S) DEPICTED AND ALL ASSOCIATED DETAILS MEET ALL APPLICABLE LAWS, REGULATIONS, AND PROJECT REQUIREMENTS.DATEDRWCHKDESCRIPTIONSALVATION ARMBOZEMAN, MT, USASHEETOF26NOTES•MANIFOLD SIZE TO BE DETERMINED BY SITE DESIGN ENGINEER. SEE TECH NOTE #6.32 FOR MANIFOLD SIZING GUIDANCE.•DUE TO THE ADAPTATION OF THIS CHAMBER SYSTEM TO SPECIFIC SITE AND DESIGN CONSTRAINTS, IT MAY BE NECESSARY TO CUT AND COUPLE ADDITIONAL PIPE TO STANDARD MANIFOLDCOMPONENTS IN THE FIELD.•THE SITE DESIGN ENGINEER MUST REVIEW ELEVATIONS AND IF NECESSARY ADJUST GRADING TO ENSURE THE CHAMBER COVER REQUIREMENTS ARE MET.•THIS CHAMBER SYSTEM WAS DESIGNED WITHOUT SITE-SPECIFIC INFORMATION ON SOIL CONDITIONS OR BEARING CAPACITY. THE SITE DESIGN ENGINEER IS RESPONSIBLE FORDETERMININGTHE SUITABILITY OF THE SOIL AND PROVIDING THE BEARING CAPACITY OF THE INSITU SOILS. THE BASE STONE DEPTH MAY BE INCREASED OR DECREASED ONCE THIS INFORMATION ISPROVIDED.•NOT FOR CONSTRUCTION: THIS LAYOUT IS FOR DIMENSIONAL PURPOSES ONLY TO PROVE CONCEPT & THE REQUIRED STORAGE VOLUME CAN BE ACHIEVED ON SITE.CONCEPTUAL ELEVATIONS:MAXIMUM ALLOWABLE GRADE (TOP OF PAVEMENT/UNPAVED):11.50MINIMUM ALLOWABLE GRADE (UNPAVED WITH TRAFFIC):5.50MINIMUM ALLOWABLE GRADE (UNPAVED NO TRAFFIC):5.00MINIMUM ALLOWABLE GRADE (TOP OF RIGID CONCRETE PAVEMENT):5.00MINIMUM ALLOWABLE GRADE (BASE OF FLEXIBLE PAVEMENT):5.00TOP OF STONE:4.50TOP OF SC-740 CHAMBER:3.5012" x 12" TOP MANIFOLD INVERT:2.0424" ISOLATOR ROW PLUS INVERT:1.01BOTTOM OF SC-740 CHAMBER:1.00BOTTOM OF STONE:0.00PROPOSED LAYOUT24STORMTECH SC-740 CHAMBERS8STORMTECH SC-740 END CAPS12STONE ABOVE (in)12STONE BELOW (in)40STONE VOID2528INSTALLED SYSTEM VOLUME (CF)(PERIMETER STONE INCLUDED)(COVER STONE INCLUDED)(BASE STONE INCLUDED)1030SYSTEM AREA (SF)141.5SYSTEM PERIMETER (ft)*INVERT ABOVE BASE OF CHAMBERMAX FLOWINVERT*DESCRIPTIONITEM ONLAYOUTPART TYPE0.10"24" BOTTOM PREFABRICATED EZ END CAP, PART#: SC740ECEZ / TYP OF ALL 24" BOTTOMCONNECTIONS AND ISOLATOR PLUS ROWSAPREFABRICATED EZ END CAPINSTALL FLAMP ON 24" ACCESS PIPE / PART#: SC74024RAMPBFLAMP12.50"12" x 12" TOP MANIFOLD, ADS N-12CMANIFOLD5.7 CFS IN30" DIAMETER (24.00" SUMP MIN)DNYLOPLAST (INLET W/ ISOPLUS ROW)ISOLATOR ROW PLUS(SEE DETAIL)PLACE MINIMUM 12.50' OF ADSPLUS625 WOVEN GEOTEXTILE OVER BEDDINGSTONE AND UNDERNEATH CHAMBER FEET FOR SCOUR PROTECTION AT ALLCHAMBER INLET ROWSBED LIMITS051050.23'20.50'44.30'18.50'BCAD