025 E1.0 Main Floor Electrical Plan
#DATETITLE SHEET NUMBER DRAWING RELEASE 109 E. Oak St., Suite 1F Bozeman, MT • 59715-2962 (406) 624-0200• www.formescent.com CONSULTANTSDRAWN BY: JJM CHECKED BY: ABR THIS DRAWING IS AN INSTRUMENT OF SERVICE AND IS TO BE USED SOLELY FOR THE PURPOSES STIPULATD UNDER SEPARATE EXECUTED CONTRACTS WITH THE ARCHITECT. THIS DOCUMENT IS COPYRIGHTED AND IS NOT TO BE USED, DUPLICATED, OR OTHERWISE MODIFIED EXCEPT WITH EXPRESS PERMISSION OF THE ARCHITECTSCOPYRIGHT © 2023 FORMESCENT ARCHITECTS, PLLC ALL RIGHTS RESERVEDSEE COVER PAGE FOR ADDITIONAL CONTACT INFORMATION1 FOR STRUCTURAL MAIN FLR ELECT PLAN E1.0 03.25.2024 PUBLISH DATE: 8/28/2024 30x42 PROJECT No.: 23112BUFFALO RESTORATION ADDITIONPROJECT INFORMATIONBOZEMAN, MT 59715GALLATIN PARK SUBDIVISION555 MANLEY RDBLOCK 2 LOT 2-A2 CITY S.P. REVIEW 08.28.2024 2 1 HIGH BAY LIGHT THROUGH WALL FANFAN# #TYPE 6" DIA. RECESSED / W BAFFLE, INCANDESCENT MANUFACTURER DESCRIPTION AND MODEL #ACCESSORIES FINISH NOTES #ROOM TYPE MANUFACTURER DESCRIPTION AND MODEL #ACCESSORIES FINISH NOTES SYMBOL TYPE MANUFACTURER DESCRIPTION AND MODEL #FINISH NOTES SWITCH LOCATION. AUTO TIMER SWITCH. MOTION DETECTOR VARIABLE SPEED FAN SWITCH DIMMER SWITCH LOW VOLTAGE CONTROL STATION DUPLEX OUTLET GROUND FAULT INTERRUPT OUTLET OUTLET LISTED FOR WET LOCATION AND GFIC 1/2 SWITCHED OUTLET, LOWER HALF QUAD OUTLET SPECIAL PURPOSE OR APPLIANCE OUTLET RECESSED FLOOR OUTLET JUNCTION BOX ILLUMINATED SWITCH LIGHTING OR SWITCHED CIRCUIT GAS SUPPLY AND SHUTOFF DOOR JAMB SWITCH BULB WALL MOUNT FIXTURE STRIP FIXTURE STRIP FIXTURE CEILING FAN & LIGHT HEIGHT A.F.F. PANEL PANEL LOCATION AS LABELED METER METER AND DISCONNECT 6" DIA. RECESSED WET LOCATION ELECTRICAL NOTES 1. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC FOR INTENT ONLY. CONTRACTOR TO PROVIDE BIDDER DESIGNED ELECTRICAL SYSTEM IN ACCORDANCE WITH ALL CODES, LAWS, AND REGULATIONS IN GOVERNING JURISDICTION. 2. CONTRACTOR TO COORDINATE WITH GOVERNING JURISDICTION FOR REQUIRED INSPECTIONS AND APPROVALS. 3. CONTRACTOR TO VERIFY EXISTING SERVICE SIZE AND LOCATION. VERIFY ADEQUACY OF EXISTING SERVICE AND PANEL SIZING AND NOTIFY OWNER OR ARCHITECT IF EXISTING SERVICE AND EQUIPMENT IS NOT ADEQUATE FOR ADDITIONAL POWER REQUIREMENTS. 4. CONTRACTOR TO PROVIDE ADDITIONAL OUTLETS AS REQUIRED BY ALL CODES, LAWS, AND REGULATIONS IN GOVERNING JURISDICTION. PER NEC 210.52 5. COORDINATION: CONTRACTOR TO COORDINATE ELECTRICAL REQUIREMENTS WITH MECHANICAL, SECURITY, AUDIO/VISUAL, HOME AUTOMATION, FIRE ALARM AND SUPPRESSION AND PLUMBING TRADES. 6. ALLOWANCES- 7. SUBMITTALS: CONTRACTOR TO PROVIDE LOAD CALCULATION SUBMITTALS AS REQUIRED BY GOVERNING JURISDICTION 8. SUBSTITUTIONS: CONTRACTOR SHALL COORDINATE WITH OWNER OR ARCHITECT AND SUBMIT FOR APPROVAL FOR ALL SUBSTITUTIONS REQUIRED DUE TO CODE REQUIREMENTS, DISCONTINUED PRODUCTS, OR CONTRACTOR RECOMMENDED VALUE ENGINEERED ITEMS. 9. FIELD CONDITIONS: NOTIFY OWNER OR ARCHITECT WHERE FIELD CONDITIONS DO NOT ALLOW FOR INSTALLTION OF DEVICE OR FIXTURE. WHERE PRIMARY STRUCTURAL COMPONENTS REQUIRE FIELD CUT AND BORING, COORDINATE WITH ARCHITECT PRIOR TO ANY MODIFICATIONS. FOR SECONDARY STRUCTURAL COMPONENTS, (JOISTS, STUDS), PROVIDE CUTTING AND BORING IN ACCORDANCE WITH MFG INSTRUCTIONS OR 2014 IRC. 10. COORDINATE TRIM AND TRIM RING AND HOUSING COMPATIBILITY PRIOR TO ROUGH IN. 11. ALL CANS FOR RECESSED LIGHTING IN CONTACT W/ INSULATION TO BE LISTED FOR APPLICATION. PROVIDE INSULATION ABOVE CANS AS REQUIRED TO MAINTAIN THERMAL AND ACOUSTICAL BARRIER CONTINUITY. PROVIDE APPROVED AIR INFILTRATION SEAL AT ALL FIXTURES LOCATED IN EXTERIOR ENVELOP. 12. ALL RECESSED LIGHTING AT EXTERIOR & IN BATHROOMS w/ SHOWERS TO BE LISTED FOR APPLICATION. 13. VERIFY ALL TRIM AND TRIM RING COLORS PRIOR TO ORDERING. COORDINATE WITH OWNER OR ARCHITECT FOR VARIATIONS IN FINISHED SURFACE COLORS. 14. VERIFY ALL FIXTURE, DEVICE, OUTLET AND J-BOX LOCATIONS LOCATIONS WITH OWNER OR ARCHITECT PRIOR TO ROUGH-IN. 15. PROVIDE UL LISTED HOUSINGS COMPATIBLE FOR EACH TYPE. 16. NOTIFY OWNER OR ARCHITECT OF ANY LOCATIONS REQUIRING EXPOSED CONDUIT OR RACEWAYS. 17. NEC210.12 ARC FAULT INTERRUPTER PROTECTION IN ALL CIRCUITS NOT GFI PROTECTED 18. NEC 210.8 & NEC 406.8 RECEPTACLES TO BE GFI PROTECTED INCLUDE BATHROOM, GARAGE, OUTDOORS, CRAWLSPACE, UNFINISHED BASEMENT, KITCHEN COUNTERS, PENNINSULAS, ISLANDS, & WET BAR SINKS. WEATHERPROOF AT EXTERIOR. 19. NEC 406.11 RECEPTACLES TO BE TAMPERPROOF. 6" DIA. RECESSED / W BAFFLE, SLOPED CAN SWITCH LIGHT & FAN SEPARATELY STORAGE LIGHT AND FIXTURE SCHEDULE APPLIANCE SCHEDULE DEVICE SCHEDULE RECESSED CEILING FAN CEILING SURFACE MOUNT FIXTURE KEYLESS FIXTURE PENDANT FIXTURE WALL MOUNT FIXTURE MECHANICAL & PLUMBING NOTES 1. CONTRACTOR TO PROVIDE BIDDER DESIGNED HVAC AND PLUMBING SYSTEMS IN ACCORDANCE WITH ALL CODES, LAWS, AND REGULATIONS IN GOVERNING JURISDICTION. 2. CONTRACTOR TO COORDINATE WITH GOVERNING JURISDICTION FOR REQUIRED INSPECTIONS AND APPROVALS. 3. PROVIDE BIDDER DESIGN AND INSTALLATION OF HVAC AND PLUMBING SYSTEMS IN ACCORDANCE WITH "ASHRAE" STANDARDS, "IECC" CODE AND INDUSTRY STANDARD PRACTICE 4. COORDINATION: CONTRACTOR TO COORDINATE MECHANICAL AND PLUMBING EQUIPMENT REQUIREMENTS WITH ELECTRICAL CONTRACTOR FOR EQUIPMENT LOADS. 5. ALLOWANCES- 6. SUBMITTALS: CONTRACTOR SHALL SUBMIT TO GOVERNING JURISDICTION FOR ALL BOILER AND FURNACE SIZING. 7. SUBSTITUTIONS: - 8. FIELD CONDITIONS: NOTIFY GENERAL CONTRACTOR OR ARCHITECT WHERE FIELD CONDITIONS DO NOT ALLOW FOR INSTALLATION OF DEVICE OR FIXTURE. WHERE PRIMARY STRUCTURAL COMPONENTS REQUIRE FIELD CUT AND BORING, COORDINATE WITH ARCHITECT PRIOR TO ANY MODIFICATIONS. FOR SECONDARY STRUCTURAL COMPONENTS, (JOISTS, STUDS), PROVIDE CUTTING AND BORING IN ACCORDANCE WITH MFG INSTRUCTIONS OR 2014 IRC. FIELD VERIFY EXISTING CONDITIONS PRIOR TO DESIGN 9. COORDINATE STYLE AND COLORS FOR ALL EXPOSED GRILLES, REGISTERS, AND DEVICES WITH GENERAL CONTRACTOR OWNER OR ARCHITECT PRIOR TO PLACEMENT OF ORDER. 10. COORDINATE ALL DUCT, PIPE, REGISTER AND EQUIPMENT SIZES WITH GENERAL CONTRACTOR, OWNER OR ARCHITECT TO INSURE CHASE, SOFFIT, AND CLEARANCES ARE ADEQUATE. MINIMUM SOFFIT HEIGHT AT SHALL BE =/> 6' -8" TO FINISHED SURFACE. ALL DUCT WORK AND PIPING IN FINISHED SPACES SHALL BE CONCEALED. 11. WHERE EXISTING CONDITIONS MAY PROHIBIT OPTIMAL PERFORMANCE OF SYSTEMS, CONTRACTOR SHALL PROVIDE IN WRITING TO GENERAL CONTRACTOR OR OWNER, PRIOR TO INSTALLATION, FORESEEABLE POTENTIAL INADEQUACY OF DESIGNED SYSTEMS DUE TO EXISTING CONDITIONS. 12. PROVIDE DUCT AND PIPE INSULATION AND SEALING IN ACCORDANCE WITH "ASHRAE" AND "IECC" STANDARDS. NOTE: "DUCT" OR "DUCK' TAPE SHALL NOT BE USED. USE ONLY APPROVED MASTIC OR TAPE TO SEAL DUCTWORK JOINTS. 13. PROVIDE MAINTENANCE AN OPERATIONS MANUALS AND MFG WARRANTY INFORMATION TO OWNER. PROVIDE TESTING AND BALANCING OF SYSTEMS AS REQUIRED TO MAINTAIN OPTIMAL PERFORMANCE THROUGH 1 YEAR. ENERGY EFFICIENCY 1. ALTERNATIVE DESIGN: CONTRACTOR IS ENCOURAGED TO PROVIDE ALTERNATIVE AND VALUE ENGINEERED SYSTEMS, WHICH PROVIDE ENHANCED PERFORMANCE, AND LIFECYCLE COSTING TO MEET OWNERS INTENT. 2. ENHANCED PERFORMANCE AND VALUE ENGINEERING: WHERE SYSTEMS OR EQUIPMENT IS INSTALLED WHICH PROVIDES ENHANCED PERFORMANCE OVER EXISTING SYSTEMS OR PROVIDES ALTERNATIVE ENERGY SOURCES, CONTRACTOR IS ENCOURAGED TO PROVIDE DOCUMENTATION ,AND NOTIFICATION OF EXISTING AND POTENTIAL GOVERNMENT CREDITS, GRANTS, FUNDING AND PROGRAMS. 3. CONTRACTOR IS ENCOURAGED TO PROVIDE DESIGN AND INSTALLATION AND DOCUMENTATION OF OF SYSTEMS AND COMPONENTS IN ACCORDANCE WITH THE "ENERGY STAR" RATING SYSTEM. RECESSED DIRECTIONAL CAN RECESSED CEILING FAN/LIGHT HIGH BAY LIGHT LITHONIA LITHONIA JEBL 18000LM PFL 40K JEBL 12000LM PFL 40K WGX WALL MOUNT FIXTURE LITHONIA LITHONIA DSXW1 10C 700 40K TFTM MVOLT DSXW2 30C 700 40K TFTM MVOLT 3 4 CREE COOPER COOPER STRIP FIXTURE6 5 EATON METALUX LS8 80L 40K 4RBG6 100D 2RBG6 75D 4CWPL4040C RECESSED STAIR LIGHTSTR PANASONIC GAS UNIT HEATERS 2ND FLR (E) AREA FURNACE UPSIZE FURNACE IF REQUIRED W1 P GAS CM K WP ## GFITLJMDFDCS#J W2 FRN RC RWP RSC RCD A A 1 B B 2 3 4 5 2 2 3 3 1 1 AA BB CC DD EE M M W WW W W FWP WPWP WP GAS C C C C C C C C FAN FAN STORAGE RESTROOMRESTROOM K K K K N SCALE: 1/4" = 1'-0" 1 MAIN FLOOR ELEC. PLAN E1.0