042 - A4.01 - TYPICAL ASSEMBLIES
S.S.D.FINISH FLOOR - SEE INTERIOR DESIGN DRAWINGS FLOOR LEVEL STC RATING :FIRE RATING : LIMITING HEIGHT : HEAD DETAIL : BASE DETAIL : FA-1 SLAB ON GRADE N/A N/A N/A N/A 03 3000 CONCRETE SLAB 03 3000 UNDERSLAB VAPOR BARRIER STC RATING :FIRE RATING : LIMITING HEIGHT : HEAD DETAIL : BASE DETAIL : FA-2 FLOOR ASSEMBLY UPPER MIN STC 50 / MIN IIC 50 1 HR UL L546 S.S.D. N/A N/A FLOOR FINISH. SEE FINISH PLANS AND SCHEDULES GYPSUM CEMENT UNDERLAYMENT ACOUSTIC MAT UNDERLAYMENT 06 1614 PLYWOOD FLOOR DECK 07 2100 GLASS-FIBER BLANKET INSULATION -UNFACED MIN. 17" SEE UL LISTING FOR MORE INFORMATION. FLOOR LEVEL 1/4" THICK MIN. 1" THICK MIN. MAX. AIR GAP 2" TO MEET NFPA 13 5/8" TYPE C GYPSUM BOARD. SEE UL LISTING FOR MORE INFORMATION. 09 2900 GYPSUM BOARD1"1/4"3/4"1 1/2"1' - 3"1 1/2"1/2"5/8"1' - 9 1/8"09 2900 GYPSUM BOARD 09 2900 GYPSUM BOARD 06 1000 WOOD FRAMING 2X8 JOIST, SEE STRUCTURAL DRWINGS 06 1614 PLYWOOD FLOOR DECK GYPSUM CEMENT UNDERLAYMENT FLOOR FINISH. SEE FINISH PLANS AND SCHEDULES 5/8" TYPE X GYPSUM BOARD. SEE LISTING FOR MORE INFORMATION. FLOOR LEVEL 07 2100 GLASS-FIBER BLANKET INSULATION -UNFACED MIN. 6" MAX. AIR GAP 2" TO MEET NFPA 13 STC RATING :FIRE RATING : LIMITING HEIGHT : HEAD DETAIL : BASE DETAIL : FA-3 FLOOR ASSEMBLY UPPER N/A 1 HR IBC TABLE 721.1(3) ITEM 21-1.1S.S.D. A8.02/A8.035/8"5/8"7 1/4"3/4"1 1/4"10 1/2"EXTERIORSTC RATING :FIRE RATING : LIMITING HEIGHT : HEAD DETAIL : BASE DETAIL : EFC1 EXT. WALL -FIBER CEMENT N/A UL# U349 (INTERIOR SIDE ONLY) X'-XX" _ _/A _. _ _ _ _/A _. _ _ 2-HR FIRE-RATED INTERIOR ONLY 07 2719 VAPOR PERMEABLE SHEET WEATHER AND AIR BARRIER 06 1600 EXTERIOR FIRE RETARDANT TREATED OSB SHEATHING 07 4646 FIBER CEMENT PANELS 07 4646 FURRING STRIP INTERIOR09 2900 GYPSUM BOARD 07 2100 REINFORCED-POLYETHYLENE VAPOR RETARDER 10 1/4" 1 1/4"2x6 1/2"1"3/8" 07 2100 GLASS-FIBER BLANKET INSULATION -UNFACED R-21 MIN. PRESSURE TREATED 07 2719 WEATHER BARRIER FLASHING 4" WIDE TAPE BEHIND FURRING 06 1000 WOOD FRAMING -FIRE RETARDANT TREATED EXTERIORSTC RATING :FIRE RATING : LIMITING HEIGHT : HEAD DETAIL : BASE DETAIL : EWA1 EXT. WALL - N/A UL# U349 (INTERIOR SIDE ONLY) X'-XX" _ _/A _. _ _ _ _/A _. _ _ 2-HR FIRE-RATED INTERIOR ONLY 1/2"4 1/16"3 1/2"1/2" 06 1600 EXTERIOR FIRE RETARDANT TREATED OSB SHEATHING 06 1600 EXTERIOR OSB SHEATHING NOTE: INSULATION IS NOT REQUIRED IN OVERFRAMING PER NFPA 13 SECTION 9.2.1.3.INTERIORR-21 MIN. 9" (RATED PORTION OF WALL) 2x61 1/4" 07 4646 FIBER CEMENT PANELS 07 2719 VAPOR PERMEABLE SHEET WEATHER AND AIR BARRIER 07 2100 GLASS-FIBER BLANKET INSULATION -UNFACED 06 1000 WOOD FRAMING OVERFRAMING OUTSIDE OF STRUCTURAL WALL 06 1000 WOOD FRAMING -FIRE RETARDANT TREATEDEXTERIORSTC RATING :FIRE RATING : LIMITING HEIGHT : HEAD DETAIL : BASE DETAIL : EWD1 EXT. WALL -WOOD N/A UL# U349 (INTERIOR SIDE ONLY) X'-XX" _ _/A _. _ _ _ _/A _. _ _ 2-HR FIRE-RATED INTERIOR ONLY 07 2719 VAPOR PERMEABLE SHEET WEATHER AND AIR BARRIER 06 1600 EXTERIOR FIRE RETARDANT TREATED OSB SHEATHING 07 4646 FURRING STRIP 07 4648 WOOD SIDING INTERIOR09 2900 GYPSUM BOARD 07 2100 REINFORCED-POLYETHYLENE VAPOR RETARDER 07 2100 GLASS-FIBER BLANKET INSULATION -UNFACED 1 1/4"2x6 1/2" 1/2" 3/4" 10 1/4" R-21 MIN. 06 1000 WOOD FRAMING -FIRE RETARDANT TREATED 07 2719 WEATHER BARRIER FLASHING 4" WIDE TAPE BEHIND FURRING PRESSURE TREATED OR CLIP SYSTEM TOP OF PLATE 06 1614 PLYWOOD ROOF SHEATHING 07 5400 VAPOR RETARDER -SPMR 06 1000 WOOD FRAMING 07 2100 GLASS-FIBER BLANKET INSULATION -UNFACED 09 2216 RESILIENT FURRING CHANNEL 09 2900 GYPSUM BOARD FILL CAVITY TO WITHIN 1" OF ROOF SHEATHING (R60 MIN.) TYPE C REQUIRED - SEE UL ASSEMBLY FOR DETAILS STC RATING :FIRE RATING : LIMITING HEIGHT : HEAD DETAIL : BASE DETAIL : RA-1 ROOF ASSEMBLY -TYPICAL N/A 1 HR UL P531 S.S.D. MIN. R-5 PER COMCHECK REQUIREMENT. 40 PSI COMPRESSIBILITY 07 5400 SINGLE PLY MEMBRANE ROOFING -SPMR 07 5400 ROOF INSULATION -SPMR STC RATING :FIRE RATING : LIMITING HEIGHT : HEAD DETAIL : BASE DETAIL : EFC2 EXT. WALL -FIBER CEMENT N/A N/A X'-XX" _ _/A _. _ _ _ _/A _. _ _ NON-RATED 07 2719 VAPOR PERMEABLE SHEET WEATHER AND AIR BARRIER 07 4646 FIBER CEMENT PANELS 07 4646 FURRING STRIP 5/8"2x6 1/2"1"3/8" R-21 MIN. 9 5/8" 06 1000 WOOD FRAMING -FIRE RETARDANT TREATED EXTERIORINTERIOR07 2719 WEATHER BARRIER FLASHING 4" WIDE TAPE BEHIND FURRING 07 2100 GLASS-FIBER BLANKET INSULATION -UNFACED 07 2100 REINFORCED-POLYETHYLENE VAPOR RETARDER 09 2900 GYPSUM BOARD 06 1600 EXTERIOR FIRE RETARDANT TREATED OSB SHEATHING STC RATING :FIRE RATING : LIMITING HEIGHT : HEAD DETAIL : BASE DETAIL : EWA2 EXT. WALL - N/A NOT RATED X'-XX" _ _/A _. _ _ _ _/A _. _ _ NON RATED EXTERIOR5/8"2x6 1/2"4 1/16"3 1/2"1/2" 06 1600 EXTERIOR FIRE RETARDANT TREATED OSB SHEATHING NOTE: INSULATION IS NOT REQUIRED IN OVERFRAMING PER NFPA 13 SECTION 9.2.1.3.INTERIOR07 2100 GLASS-FIBER BLANKET INSULATION -UNFACED R-21 MIN. 8 3/8"8 1/8" 07 4646 FIBER CEMENT PANELS 07 2719 VAPOR PERMEABLE SHEET WEATHER AND AIR BARRIER 06 1600 EXTERIOR OSB SHEATHING 06 1000 WOOD FRAMING OVERFRAMING OUTSIDE OF STRUCTURAL WALL 06 1000 WOOD FRAMING -FIRE RETARDANT TREATED STC RATING :FIRE RATING : LIMITING HEIGHT : HEAD DETAIL : BASE DETAIL : EWD2 EXT. WALL -WOOD N/A N/A X'-XX" _ _/A _. _ _ _ _/A _. _ _ 07 2719 VAPOR PERMEABLE SHEET WEATHER AND AIR BARRIER 06 1600 EXTERIOR FIRE RETARDANT TREATED OSB SHEATHING 07 4646 FURRING STRIP 07 4648 WOOD SIDING 09 2900 GYPSUM BOARD 07 2100 REINFORCED-POLYETHYLENE VAPOR RETARDER 07 2100 GLASS-FIBER BLANKET INSULATION -UNFACED 5/8"2x6 1/2" 1/2" 3/4" 9 5/8" R-21 MIN. PRESSURE TREATED OR CLIP SYSTEM 07 2719 WEATHER BARRIER FLASHING 4" WIDE TAPE BEHIND FURRING 06 1000 WOOD FRAMING -FIRE RETARDANT TREATED EXTERIORNON-RATEDINTERIOR STC RATING :FIRE RATING : LIMITING HEIGHT : HEAD DETAIL : BASE DETAIL : RA-2 CANAPOY ASSEMBLY N/A NON RATED N/A N/A 05 3100 COMPOSITE STEEL DECKING TAPERED STEEL BEAM STC RATING :FIRE RATING : LIMITING HEIGHT : HEAD DETAIL : BASE DETAIL : RA-3 ROOF ASSEMBLY -ELEVATOR N/A 1 HR UL P531 S.S.D. A8.02/A8.03 06 1614 PLYWOOD ROOF SHEATHING 07 5400 VAPOR RETARDER -SPMR 07 5400 ROOF INSULATION -SPMR 06 1000 WOOD FRAMING 07 2100 GLASS-FIBER BLANKET INSULATION -UNFACED FILL CAVITY TO WITHIN 1" OF ROOF SHEATHING MIN. R-5 PER IECC 2022 TYPE X REQUIRED - SEE ASSEMBLY FOR DETAILS MAX. AIR GAP 2" TO MEET NFPA 13 S.S.D. ASSUMED 2X10 JOISTS 09 2900 GYPSUM BOARD 07 5400 SINGLE PLY MEMBRANE ROOFING -SPMR STC RATING :FIRE RATING : LIMITING HEIGHT : HEAD DETAIL : BASE DETAIL : FA-4 FLOOR ASSEMBLY -UPPER 59 STC / 53 IIC 1 HR. UL L546 S.S.D. A8.02/A8.03 A8.02/A8.03 FLOOR FINISH. SEE FINISH PLANS AND SCHEDULES GYPSUM CEMENT UNDERLAYMENT ACOUSTIC MAT UNDERLAYMENT 06 1614 PLYWOOD FLOOR DECK 5/8" TYPE C GYPSUM BOARD. SEE UL LISTING FOR MORE INFORMATION. 09 2900 GYPSUM BOARD 09 2216 RESILIENT FURRING CHANNEL 07 2100 GLASS-FIBER BLANKET INSULATION -UNFACED MIN. 17" SEE UL LISTING FOR MORE INFORMATION. FLOOR LEVEL 1/4" THICK MIN. 1" THICK MIN. MAX. AIR GAP 2" TO MEET NFPA 13 06 1053 PLYWOOD BACKING PANEL 07 2100 REINFORCED-POLYETHYLENE VAPOR RETARDER -TI 07 4646 FIBER CEMENT PANELS STC RATING :FIRE RATING : LIMITING HEIGHT : HEAD DETAIL : BASE DETAIL : FA-5 FLOOR ASSEMBLY -UPPER 59 STC / 53 IIC 1 HR. UL L546 S.S.D. A8.02/A8.03 A8.02/A8.03 FLOOR FINISH. SEE FINISH PLANS AND SCHEDULES GYPSUM CEMENT UNDERLAYMENT ACOUSTIC MAT UNDERLAYMENT 06 1614 PLYWOOD FLOOR DECK 5/8" TYPE C GYPSUM BOARD. SEE UL LISTING FOR MORE INFORMATION. 09 2900 GYPSUM BOARD 09 2216 RESILIENT FURRING CHANNEL 07 2100 GLASS-FIBER BLANKET INSULATION -UNFACED MIN. 17" SEE UL LISTING FOR MORE INFORMATION. FLOOR LEVEL 1/4" THICK MIN. 1" THICK MIN. MAX. AIR GAP 2" TO MEET NFPA 13 06 1053 PLYWOOD BACKING PANEL 07 2100 REINFORCED-POLYETHYLENE VAPOR RETARDER -TI STC RATING :FIRE RATING : LIMITING HEIGHT : HEAD DETAIL : BASE DETAIL : EBR1 EXT. WALL -BRICK N/A N/A X'-XX" _ _/A _. _ _ _ _/A _. _ _EXTERIORNON-RATEDINTERIOR CLAY FACING BRICK, E-FAC-05 ADJUSTABLE VENEER ANCHOR 16" O.C. VERTICALLY AND 24" O.C. HORIZONTALLY 07 2719 VAPOR PERMEABLE SHEET WEATHER AND AIR BARRIER 09 2900 GYPSUM BOARD 07 2100 REINFORCED-POLYETHYLENE VAPOR RETARDER 07 2100 GLASS-FIBER BLANKET INSULATION -UNFACED R-21 MIN. 06 1000 WOOD FRAMING -FIRE RETARDANT TREATED AIR-BARRIER & WATER- RESISTANT OSB SHEATHING Drawn By: Checked By: Project Number: Sheet Number: © 2023 Solomon Cordwell Buenz TYPICAL ASSEMBLIES 321 N 5TH AVE BOZEMAN, MT 59715 THE GUTHRIE AT 5TH AND VILLARD A4.01 MAD BS 2023029 NO. DATE DESCRIPTION 1 9/6/2024 ISSUED FOR SITE PLAN REVIEW