Loading...
HomeMy WebLinkAbout031 - L 601 - Overall Irrigation PlanSSSSSDSDSDSDSDSDSDSDSDSDW W W W W W W W W W W W W W WSSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSS SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SDSDSDSDSDSDSD[][][][][][][][][][][][]>>>>>>>>>UGEUGEUGEUGEOHEOHE OHE OHE OHE OHE OHE OHE OHEOHEUGEUGEUGEUGEUGE WWWWSDSD>>>>>>>>>>>>>>>>WW>>UGEUGEUGEUGEUGE>>>>>>WSSGAS GAS GAS GASGASSDSDSDSDSDSD12456879101112131415161718192021223232425262728SDSDUGCUGCUGCSDSDGASGASGASUGEUGECPSPR REDREDREDNORNORNORCP MEP TO PROVIDE 1.5" STUB ANDBACKFLOW PREVENTER FORIRRIGATION IN HOUSEMECHANICAL ROOM PLACEBACKFLOW PREVENTION NEARFLOOR DRAINS.MAIN LINE ISOLATION VALVE,& QUICK COUPLER FOR BLOWOUT USEWEATHER STATIONVERIFY LOCATIONIN FIELDWALL MOUNTEDOUTDOOR CONTROLLERVERIFY LOCATION IN FIELD, ELECTRICAL AND ARCH. TO PROVIDE& COORDINATE POWER OUTLETIRRIGATION SLEEVE, TYP.ZONE 3D1.0"0.50BFWCIRR MAINIRR MAIN IRR MAIN IRR MAIN IRR MAIN IRR MAIN IRR MAINIRR MAINIRR MAINIRR MAINIRR MAINIRR MAINIRR MAINIRR MAINIRR MAINIRR MAINIRR MAINIRR MAINIRR MAINIRR MAINIRR MAINIRR MAINIRR MAINIRR MAINIRR MAINIRR MAINDDDDDDDDDDDD DDDD DDDDDDDD121212121212DD 2D2DT1DT1D5D3DTIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRR IRR DDDDDDDDDDDDDDDDDDDDDDDDDDD DDDIRRIRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRRDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDD IRR IRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRZONE 2D1.0"1.28ZONE 2DT1.0".53ZONE 5D1.0"1.75ZONE 4D1.0"0.57ZONE 1S1.0"3.40ZONE 6D1.0".18ZONE 7D1.0".91ZONE 3DT1.0".20DDDDDDDDDDIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRR IRR IRR IRR IRR IRR IRR IRR IRR1S6DDDDDDDDDD DDD DDDDDDDDDDDDDDDDIRRIRRIRR IRRIRRDD DDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDD DDDDDDD D DDDDDDDDDDDDDD DIRR IRRZONE 1D1.0"1.54ZONE 1DT1.0".133DDDD D D DDD D D D D D D D D DD DD DDD DDD DDD DDD DDD4D7D121212121212 FINISH GRADESCH. 40 PVC SLEEVE - 4" MIN. OR2X THEO.D. OF THE IRRIGATION PIPINGWRAP 12 GAUGE WIRE AROUND EACHEND OF THE SLEEVE AND EXTEND TOTHE SURFACEWASHED AND GRADED MORTARSAND BACKFILL IN ROCKY SOIL.PAVEMENT EDGENOTE:1.CAP SLEEVES UNTIL USE.2.4" MIN. HORIZONTAL SEPARATION REQUIRED BETWEEN SLEEVESIN THE SAME TRENCH.3.IRRIGATION PIPE AND CONTROL WIRES SHALL BE SLEEVEDSEPARATELY.4.SOIL AROUND SLEEVE BACKFILLED AND COMPACTED TO THESAME DENSITY AS THE SURROUNDING SOIL.DEPTH PER TRENCHING DETAIL2L601NTSIrrigation SleeveDDIRRIRR1.5" PVC MAINLINE, SCH 40 PVC1.0" LATERAL LINE, SCH 40 PVC ORPOLYETHYLENE (PE)SOFT WALL DRIP TUBING WITH POINTSOURCE EMITTER. RAINBIRD XERI-TUBE700, w/ RAINBIRD XB-05PC AND XB-10PCEMITTERS OR EQUIV SYM DESCRIPTIONIRRIGATION LEGENDIRRIGATION SLEEVE, 4" Min. SCH 40 PVC IRRIGATION CONTROLLERBACKFLOW PREVENTER1.5"CONNECTION POINT1, L700WEATHER STATION (SEE DETAIL)CONTROL VALVE1.0"DRIP CONTROL VALVEHUNTER PR0S-06-PRS40 POPUPSPRAYBODY WITH MPR 1000NOZZLE(90°-360°)VALVE SCHEDULE1.0"SIZE DETAIL BFCPWCISOLATION VALVE/GATE VALVE DRAINQUICK COUPLER FOR BLOW OUT USE1.0"122, L7003, L7009, 11,12 L70010, L7008, L7004, L7001, L7015, L7005, L7003-4, L7016, L700**PRS 40 BODIES DESIGNED TO REGULATE PRESSURES AT 40PSI PER HEAD,HEADS TO BE ADJUSTED TO ACHIEVE PROPER ARC RADIUS.ZONE #/TYPESIZEGPMZONE TYPESS= MP ROTATOR OR SPRAY NOZZLE (SEE IRRIGATION LEGEND)D= DRIP IRRIGATIONDT= DRIP TREE IRRIGATIONIRR MAINDDD WATTS 009 RPZ OR EQUIVALENT HUNTER ICC2 OR EQUIVALENT HUNTER PGV, ICV OR SIMILAR HUNTER PCZ, ICZ DRIP CONTROL KIT W/ PRESSURE REGULATOR & FILTERNIBCO T-113 BRONZE GATE VALVE OR SIMIALARRAINBIRD HQ44-RC OR SIMILAR1.0"QTY11111101112Overall IrrigationPlanL 601168032N1L6011/16"=1'-0"Overall Irrigation PlanWEST VILLARD STREETNORTH 5TH AVE design5la.com406.587.4873dateissuedrawn by:checked by:filename:z:\the porch\autocad\01_sheets\l600_thestandard_irrigation.dwg The Guthrie at 5th & Villard Bozeman, Montana KHM/HU TMS NOT FORCONSTRUCTION09/06/24Site Plan Review10/11/24Site Plan Revision 1.1