HomeMy WebLinkAbout003 - A201 - 1ST FLOOR PLANGENERAL PLAN NOTES
1. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION.
2. THE CONTRACTOR SHALL NOT CONSIDER CONSTRUCTION NOTES TO BE
ALL-INCLUSIVE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSPECT AND
ASSESS EACH AREA AND TO FULFILL THE INTENT OF THE CONTRACT
DOCUMENTS. CONTRACTOR SHALL COORDINATE ARCHITECTURAL
CONSTRUCTION DRAWING AND NOTES WITH CIVIL, STRUCTURAL AND
MECHANICAL, ELECTRICAL & PLUMBING NOTES AND DRAWINGS.
3. FIELD VERIFY ALL DIMENSIONS. DO NOT SCALE DRAWINGS. THE
CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF ANY
DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THE CONTRACT
DOCUMENTS PRIOR TO COMMENCING WORK.
4. ALL FINISHES AND MATERIALS SHALL BE PROPERLY INTEGRATED TO
ENSURE A UNIFORM APPEARANCE AND SEAMLESS TRANSITION.
5. PROVIDE ALL BACKING FOR MILLWORK, GRAB BARS, AND ANY AND ALL WALL
MOUNTED EQUIPMENT OR ACCESSORIES; COORDINATE LOCATIONS.
6. ALL DIMENSIONS ARE FROM STRUCTURAL GRIDLINES OR UNFINISHED FACE
OF STUD, UNLESS OTHERWISE NOTED.
7. GENERAL CONTRACTOR SHALL COORDINATE ALL ASPECTS OF THE
BUILDING CONSTRUCTION.
8. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH AND REPAIR ALL
INCONSISTENCIES IN FLOOR ELEVATIONS.
9. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED TO PROVIDE
SUITABLE SUBSTRATE FOR FINISHES.
10. LOCATE THE HINGE SIDE JAMB OF DOORS 4 1/2" FROM ADJACENT
PERPENDICULAR WALL, UNLESS NOTED OTHERWISE.
11. INSULATION TO MEET THE FOLLOWING MINIMUMS:
WALLS: R-21
FLOOR: R-30
CEILING/ROOF: R-38
12. PROTECTION OF PENETRATIONS OF WALL OR FLOOR/CEILING ASSEMBLIES
REQUIRED TO BE FIRE-RESISTANCE RATED IN ACCORDANCE WITH IRC
SECTIONS R302.3 AND R302.5.
13. FIREBLOCKING SHALL BE PROVIDED TO CUT OFF BOTH VERTICAL AND
HORIZONTAL CONCEALED DRAFT OPENINGS AND TO FORM AN EFFECTIVE
FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND THE
ROOF SPACE. FOR SPECIFIC LOCATIONS WHERE FIREBLOCKING IS
REQUIRED, SEE IRC SECTION R302.11.
A402
1
A401
A402
A401
1
2
2
2
A301
2
A301
GARAGE
100
803 SF
1
A301
1
A301A C
1
DB
36' - 0"
01
04
STORAGE/
EQUIPEMENT
COVERED AREA
BELOW DECK
COVERED AREA
BELOW DECK
8' - 0"24' - 0"7' - 8"02
5' - 0"28' - 6 5/8"15' - 9"7' - 0"12' - 0"5' - 6"
1' - 6"4' - 0"6' - 0"3' - 10"1' - 6"14' - 0"3' - 0"9' - 0"1' - 6"1' - 2"1' - 6"
FD
03100.3A 100.2
100.4100.1
20' - 0"
R @ 7 1/2"16
125 NORTH WALLACE AVE.
BOZEMAN, MT 59715
DATE ISSUED:
CURRENT REVISION #:
CURRENT REVISION DATE:
PROJECT NUMBER:
A201
1ST FLOOR PLAN
Checker
Author
Issue Date
2406PROJ # 2406: 521 S BLACK AVE ADUJERRAD INLOW & JENNIFER HOEY521 S BLACK AVE.BOZEMAN, MT 59715NCOA3/8" = 1'-0"1 1ST FLOOR PLAN - GARAGE
N