Loading...
HomeMy WebLinkAbout002 - A101 - SITE PLANSITE PLAN LEGEND SEWER SERVICE LINE PROPERTY LINE CATV PARKING SPACE SETBACK WATER LINE UTILITY ZONE SITE PLAN NOTES 1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY, COUNTY, STATE, FEDERAL AND OSHA REGULATIONS. 2. CONTRACTOR SHALL REFER TO THE ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING, RAMPS, SIDEWALKS, EXIT PORCHES, PRECISE BUILDING DIMENSIONS, EXACT BUILDING UTILITY ENTRANCE LOCATIONS, AND TOTAL NUMBER, LOCATION, AND SIZE OF DOWNSPOUTS. 3. ALL DISTURBED AREAS ARE TO RECEIVE FOUR INCHES OF TOPSOIL, SEED, MULCH, AND WATER UNTIL A HEALTHY STAND OF GRASS IS ESTABLISHED. 4. ALL DIMENSIONS AND RADII ARE TO THE BACK OF CURB, EDGE OF PAVEMENT, CENTER OF STRIPE OR OBJECT, OR FACE OF BUILDING UNLESS OTHERWISE NOTED. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL RELOCATIONS, INCLUDING BUT NOT LIMITED TO, ALL UTILITIES, STORM DRAINAGE, SIGNS, TRAFFIC SIGNALS & POLES, ETC. AS REQUIRED. ALL WORK SHALL BE DONE IN ACCORDANCE WITH GOVERNING AUTHORITIES SPECIFICATIONS AND SHALL BE APPROVED BY SUCH. ALL COST SHALL BE INCLUDED IN BASE BID. 6. GROUND SURROUNDING DWELLINGS SHALL SLOPE AWAY AT MIN. 6" PER 10' OR 2% FOR IMPERVIOUS SURFACES. IRC 401.3 7. CONTRACTOR IS RESPONSIBLE FOR PROTECTION AND REPLACEMENT OF PROPERTY CORNERS. 8. CONTRACTOR SHALL MATCH EXISTING CURB & GUTTER IN GRADE, SIZE, TYPE AND ALIGNMENT WHERE APPLICABLE. 9. SURFACE DRAINAGE SHALL BE DIVERTED TO A TO A STORM SEWER CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT DOES NOT CREATE A HAZARD. IRC 401.3 ROOFS, OR SIMILAR AREAS HAVING RAINWATER SHALL FLOW AWAY FROM THE ADJOINING PROPERTY (UPC 1101.2) GAS LINE ELECTRICAL LINE OVERHEAD WIRES/CABLES INGRESS/EGRESS POINTS TELEPHONE LINE (UNDERGROUND) TOPOGRAPHY 1 0 0 .2 0 '1 0 0 .3 6 '1 0 0 .5 3 '1 0 0 .7 0 '1 0 0 .8 6 '100.53' 100.20' EXISTING TREE EXISTING GARAGE (TO BE DEMOLISHED) EXISTING BUILDING EXISTING PARKINGEXISTING PARKINGS BLACK AVE.ALLEYEXISTING PARKING EXISTING PARKING 4251 SF REAR YARD EXISTING CONCRETE PATHWAY EXISTING PATIO EXISTING PATIO EXISTING DRIVEWAY 24' - 0" VIF 24' - 0" VIFEXISTING ADJACENT PROPERTY FENCE, VIF EXISTING ADJACENT PROPERTY FENCE, VIF 20' RIGHT-OF-WAY 5' SIDE SETBACK LINE 15' FRONT SETBACK LINE 5' SIDE SETBACK LINE 6' REAR SETBACK LINE PER BMC 38.360.030.I 1 0 0 .2 0 '1 0 0 .3 6 '1 0 0 .5 3 '1 0 0 .7 0 '1 0 0 .8 6 '100.53' 100.20' EXISTING TREE EXISTING BUILDING EXISTING PARKINGEXISTING PARKINGS BLACK AVE.ALLEY4251 SF REAR YARD EXISTING CONCRETE PATHWAY EXISTING PATIO EXISTING ADJACENT PROPERTY FENCE, VIF EXISTING ADJACENT PROPERTY FENCE, VIF 20' RIGHT-OF-WAY 6' REAR SETBACK LINE PER BMC 38.360.030.I 5' SIDE SETBACK LINE 15' FRONT SETBACK LINE 5' SIDE SETBACK LINE NEW CONSTRUCTION PARKING SPACE PARKING SPACE OUTLINE OF DECK ABOVE HOT TUB 125 NORTH WALLACE AVE. BOZEMAN, MT 59715 DATE ISSUED: CURRENT REVISION #: CURRENT REVISION DATE: PROJECT NUMBER: A101 SITE PLAN Checker Author Issue Date 2406PROJ # 2406: 521 S BLACK AVE ADUJERRAD INLOW & JENNIFER HOEY521 S BLACK AVE.BOZEMAN, MT 59715NCOA1/8" = 1'-0"1 SITE PLAN - EXISTING + DEMO N N1/8" = 1'-0"2 SITE PLAN - PROPOSED PARKING CALCULATIONS PER BMC 38.360.040, NO ADDITIONAL PARKING IS REQUIRED FOR ADU'S EXISTING PARKING: 4 SPACES PROPOSED PARKING: 4 SPACES