HomeMy WebLinkAbout005 - A203 - 2ND FLOOR PLANGENERAL PLAN NOTES
1. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.
2. THE CONTRACTOR SHALL NOT CONSIDER CONSTRUCTION NOTES TO BE ALL-INCLUSIVE. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO INSPECT AND ASSESS EACH AREA AND TO FULFILL THE INTENT
OF THE CONTRACT DOCUMENTS. CONTRACTOR SHALL COORDINATE ARCHITECTURAL
CONSTRUCTION DRAWING AND NOTES WITH CIVIL, STRUCTURAL AND MECHANICAL, ELECTRICAL &
PLUMBING NOTES AND DRAWINGS.
3. FIELD VERIFY ALL DIMENSIONS. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THE
CONTRACT DOCUMENTS PRIOR TO COMMENCING WORK.
4. ALL FINISHES AND MATERIALS SHALL BE PROPERLY INTEGRATED TO ENSURE A UNIFORM
APPEARANCE AND SEAMLESS TRANSITION.
5. PROVIDE ALL BACKING FOR MILLWORK, GRAB BARS, AND ANY AND ALL WALL MOUNTED EQUIPMENT
OR ACCESSORIES; COORDINATE LOCATIONS.
6. ALL DIMENSIONS ARE FROM STRUCTURAL GRIDLINES OR UNFINISHED FACE OF STUD, UNLESS
OTHERWISE NOTED.
7. GENERAL CONTRACTOR SHALL COORDINATE ALL ASPECTS OF THE BUILDING CONSTRUCTION.
8. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH AND REPAIR ALL INCONSISTENCIES IN
FLOOR ELEVATIONS.
9. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED TO PROVIDE SUITABLE SUBSTRATE
FOR FINISHES.
10. LOCATE THE HINGE SIDE JAMB OF DOORS 4 1/2" FROM ADJACENT PERPENDICULAR WALL, UNLESS
NOTED OTHERWISE.
11. INSULATION TO MEET THE FOLLOWING MINIMUMS:
WALLS: R-21
FLOOR: R-30
CEILING/ROOF: R-38
12. PROTECTION OF PENETRATIONS OF WALL OR FLOOR/CEILING ASSEMBLIES REQUIRED TO BE FIRE-
RESISTANCE RATED IN ACCORDANCE WITH IRC SECTIONS R302.3 AND R302.5.
13. FIREBLOCKING SHALL BE PROVIDED TO CUT OFF BOTH VERTICAL AND HORIZONTAL CONCEALED
DRAFT OPENINGS AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A
TOP STORY AND THE ROOF SPACE. FOR SPECIFIC LOCATIONS WHERE FIREBLOCKING IS REQUIRED,
SEE IRC SECTION R302.11.
14. FURNITURE FOR REFERENCE ONLY.
A4011
A402
A401
A402
1
2
2
OFFICE
205
BEDROOM
207
BATHROOM
206
A501
1
A502
6
1
A301
1
A301
3
A301
3
A301
W/D & COAT
202
POWDER
201
DINING & LIVING ROOM
204
4
A301
4
A301
DC
2
1
EA
2
A301
2
A301
A502
1
200.1201.1205.1 207.1F
I
M
L
LI
I
C
EW2
EW2
EW2
EW2
W2
W1
W1
W2
W1
W1
W1
GAS STOVE/ROUGH-IN NOT INCLUDED IN
ARCH CONTRACT. PROVIDE GAS LINE
FOR FUTURE INSTALLATION OF STOVE.
PROVIDE GAS LINE FOR RANGE.
GAS RANGE IS IN ADDITION TO
ARCH CONTRACT.
PROVIDE GAS LINE FOR GRILL. GAS LINE
IS IN ADDITION TO ARCH CONTRACT.
PLUMB WATER TO TOILET
FROM INTERIOR WALL.
206.1
N
3
B
E
28' - 6"
4' - 6"20' - 6 1/2"4' - 6"35' - 9 1/4"8' - 10"6' - 10"2 3/4"14' - 5 1/2"10' - 3 3/4"5' - 5 1/2"9' - 8 1/2"3' - 7 1/2"3' - 2 3/4"5' - 0"2 3/4"5' - 0"4' - 2"2' - 11 1/2"5' - 11"EQEQADU ENTRY
200
202.1KITCHEN
203
968 SF
W2
W1
125 N Wallace Ave.
Bozeman, MT 59715
DATE ISSUED:
REVISION #:
REVISION DATE:
PROJECT NUMBER:
A203
2ND FLOOR
PLAN
Checker
Author
NA
2401PROJ # 2401: S 11TH AVE ADUHOWIE SEIM & MARTHA TISSOT VAN PATOT216 S 11TH AVEBOZEMAN, MT 59715NCOA3/8" = 1'-0"1 2ND FLOOR PLAN
N