HomeMy WebLinkAbout007--A2.3 Basement Floor PlanWDWDWDWDUPWDWDUPUPUPUPUPFFGGJJMM11334455KKHH22EELLCLCLACCESSORYLIVING UNITA1-001HALL1-001FLEX ROOM1-004MUD ROOM1-005BATH1-006TV.BASEMENT PATIOBASEMENT PATIOMECH/ELEC1-002ACCESSORYLIVING UNITA3-001HALL3-001TV.FLEX ROOM3-004MUD ROOM3-005BATH3-006BASEMENT PATIOMECH/ELEC3-002HALL2-001MUD ROOM2-005BATH2-006ACCESSORYLIVING UNITA2-001ALU BATHA2-002FLEX ROOM2-004MECH/ELEC2-002A6.21PLANTERPLANTERPLANTERDDCCcl1cl1IIALU BATHA1-002PANTRY/LINA1-003TV.ALU ENTRY COURTYARDALU ENTRY COURTYARDA6.141111111110 PERMANENTLY WIRED, INTERCONNECTED SMOKE DETECTOR WITH BATTERY BACKUP AND CARBON MONIXIDE ALARMSDSTAIR & HANDRAIL NOTESSTAIR WIDTHSHALL NOT BE LESS THAN 36" IN CLEAR WIDTH. (IRC-R311.7.1)TREADS & RISERSTHE MAX. RISER HEIGHT SHALL BE 7-3/4" (IRC-R311.7.5.1) AND THE MIN. TREAD DEPTH SHALL BE 10". (IRC-R311.7.5.2)WINDER TREADSSHALL HAVE A MIN. TREAD DEPTH OF 10" MEASURED AT A POINT 12" FROM THE SIDE WHERE THE TREADS ARE NARROWER. WINDER TREADS SHALLHAVE A MIN. TREAD DEPTH OF 6" AT ANY POINT. (IRC-R311.7.5.2)LANDING WIDTHSHALL NOT BE LESS THAN THE STAIRWAY OR DOOR SERVED. EVERY LANDING SHALL HAVE A MIN. DIM. OF 36" MEASURED IN THE DIRECTION OF TRAVEL. (IRC-R311.7.6)HANDRAIL HEIGHTSHALL BE A MIN. OF 34" AND A MAX. OF 38" MEASURED VERTICALLY FROM THE NOSING OF THE TREADS, AND SHALL BE PROVIDED ON AT LEAST ONE SIDE OF STAIRWAYS. (IRC-R311.7.8.1)CONTINUITYHANDRAILS FOR STAIRWAYS SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT, FROM A POINT DIRECTLY ABOVE THE TOP RISER OF THE FLIGHT TO A POINT DIRECTLY ABOVE THE LOWEST RISER OF THE FLIGHT. HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEWEL POSTS OR SAFETY TERMINALS. HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPACE OF NOT LESS THAN 1-1/2" BETWEEN THE WALL AND THE HANDRAIL. (IRC-311.7.8.2)GUARDRAIL HEIGHTSHALL NOT BE LESS THAN 36". (IRC-R312.1.2)RAIL SPACINGRAILS SHALL BE SPACED SO AS NOT TO ALLOW PASSAGE OF A SPHERE 4" IN DIA. (IRC-R312.1.3)THE TRIANGULAR OPENING AT THE OPEN SIDE OF THE STAIR, FORMED BY THE RISER, TREAD AND BOTTOM RAIL OF A GUARD, SHALL NOT ALLOW THE PASSAGE OF A SPHERE 6 INCHES IN DIAMETER. (IRC-312.1.3 -1)GUARDS ON THE OPEN SIDES OF THE STAIRS SHALL NOT HAVE OPENINGS THAT ALLOW PASSAGE OF A SPHERE 4-3/8 INCHES IN DIAMETER. (IRC-312.1.3 -2) CLOTHES DRYER VENTINGA. MAX. LENGTH SHALL NOT EXCEED 35' FROM DRYER LOCATION TO OUTLET TERMINALB.LENGTH REDUCED BY 2'6" FOR EACH 45° BENDC.LENGTH REDUCED BY 5' FOR EACH 90° BENDD.EXCEPTION: WHERE MAKE AND MODEL CLOTHES DRYER IS KNOWN AND OF MANUFACTURER'S INSTALLATION INSTRUCTIONS PROVIDED TO CODE OFFICIAL, MANUFACTURER'S SPECS MAY BE USED.FURNACE E.EQUIPMENT INSTALLED AT GRADE LEVEL SHALL BE SUPPORTED ON A LEVEL CONCRETE SLAB EXTENDING A MINIMUM OF 3" ABOVE ADJOINING GRADE OR IT SHALL BE SUSPENDED A MINIMUM OF 6" ABOVE ADJOINING GRADEF.AN APPROVED FUEL SHUTOFF VALVE SHALL BE INSTALLED IN THE FUEL SUPPLY PIPING SERVING EACH PIECE OF FUEL BURNING EQUIPMENT AT AN ACCESSIBLE LOCATION AHEAD OF THE UNION OR APPLIANCE CONNECTION WITHIN 36" OF THE EQUIPMENTG.FURNACE TO BE LOCATED WITHIN 20 FEET OF THE CRAWL SPACE OPENING -AN APPROVED INDEPENDENT MEANS OF DISCONNECT FOR THE ELECTRICAL SUPPLY TO EACH PIECE OFEQUIPMENT, SUB BOXH.PERMANENT SWITCH CONTROLLED LIGHTING SHALL BE INSTALLED FOR MAINTENANCE OF EQUIPMENT; REQUIRED TO BE ACCESSIBLE OR READILY ACCESSIBLEI.A 120-VOLT SERVICE RECEPTACLE SHALL BE LOCATED WITHIN 25 FEET OF AND ON THE SAME LEVEL AS THE EQUIPMENT FOR MAINTENANCEJ.EXHAUST VENT FOR HIGH EFFICIENCY FURNACE TO BE CPVC OR OTHER HIGH TEMPERATURE MATERIAL2345678910FEDCBAGH1NOT FOR CONSTRUCTIONREVISIONSPROJECT NO:DATE:22002August 30, 2023All reports, drawings, specifications, computer files, field data, notes, other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect, LocalElementArchitects, LLC. The Architect shall retain all common law, statutory and other reserved rights, including copyright thereto. The use of this drawing shall be restricted to the original site for which it was prepared and publication thereof is expressly limited to such use. Reuse, reproduction or publication by any method is prohibited without written consent from LocalElementArchitects, LLC. NCOA SUBMITTAL10/9/2024 2:27:52 PM C:\Users\chris\OneDrive\Documents\Villard Floor Plans_Central_chrisTMMND.rvtLAYERCAKE TOWNHOMES314 W VILLARD STBOZEMAN, MT 59715A2.4NOTED BASEMENTFLOOR PLANSCALE: 3/16" = 1'-0"1NOTED BASEMENT FLOOR PLANKEYNOTESSMOKE DETECTOR LEGENDGENERAL PLAN NOTESNORTHUNIT 1 AREA CALCULATIONSNAMEAREACOVERED PATIOBASEMENT PATIO102 SFFRONT ENTRY22 SFCOVERED PATIO124 SFLIVABLEUNIT 1 ALU515 SFUNIT 1 BASEMENT597 SFUNIT 1 MAIN FLOOR 1032 SFUNIT 1 UPPER LEVEL 1132 SFLIVABLE3276 SF3400 SFUNIT 2 AREA CALCULATIONSNAMEAREACOVERED PATIOBASEMENT PATIO97 SFFRONT ENTRY20 SFCOVERED PATIO118 SFLIVABLEUNIT 2 BASEMENT575 SFUNIT 2 ALU504 SFUNIT 2 MAIN FLOOR 1007 SFUNIT 2 UPPER LEVEL 1105 SFLIVABLE3191 SF3309 SFUNIT 3 AREA CALCULATIONSNAMEAREACOVERED PATIOBASEMENT PATIO103 SFFRONT ENTRY22 SFCOVERED PATIO125 SFLIVABLEUNIT 3 ALU516 SFUNIT 3 BASEMENT596 SFUNIT 3 MAIN FLOOR 1032 SFUNIT 3 UPPER LEVEL 1130 SFLIVABLE3274 SF3398 SFCOVERED SURFACE PARKING...NAMEAREACOVERED PARKING 1456 SF1456 SF2REVISIONSNO. DATE DESCRIPTION1 08/22/2024 NCOA Revision 12 10/05/2024 NCOA Revision 2