HomeMy WebLinkAbout002--A0.1 Project Information1A101SIMDRAWING NUMBERSECTION MARKSHEET NUMBERWINDOW DESIGNATIONDOOR DESIGNATIONWALL TYPENAMEELEVATIONELEVATION DATUMKEYNOTE DESIGNATION?REVISION NOTE1HEIGHT SYMBOLTTEMPEREDSMOKE DETECTOR/CARBON MONOXIDE DETECTORSDFIRE SPRINKLER SYSTEMWHOLE HOUSE (NFPA-13R ONLY IF <12,000 SF UNDER ROOF) SPRINKLER SYSTEM TO BE INSTALLED PER THE REQUIREMENTS OF THE CITY OF BOZEMAN, WITH REVIEW AND APPROVAL. SUBMIT FIRE SPRINKLER DRAWINGS PRIOR TO FABRICATION OR INSTALLATION OF FIRE SPRINKLER SYSTEM.GEOCODE: 06-0798-12-1-34-12-0000LEGAL DESCRIPTION: KARP ADD, S12, T02 S, R05 E, BLOCK 5, Lot 7, ACRES 0.222, E 19' LOT 6, PLAT E-3CODE JURISDICTION: CITY OF BOZEMAN, MTBUILDING CODES:2021 INTERNATIONAL RESIDENTIAL CODE (IRC)2021 INTERNATIONAL MECHANICAL CODE (IMC)2021INTERNATIONAL PLUMBING CODE (IPC)2020NFPA 70 NATIONAL ELECTRIC CODE2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)2021INTERNATIONAL FUEL GAS CODE (IFGC)2017 ICC A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES ZONING DISTRICTOCCUPANCYCONSTRUCTION TYPEROOF/ ROOF CEILINGSHAFT ENCLOSURESZONING DISTRICTREQUIREDPROPOSEDMAX LOT COVERAGE:MAX FARMAX BUILDING HEIGHTPROPERTY SETBACKSFRONTSIDEREARW/ 20'-0" ALLEY R.O.W15'-0"5'-0"20'-0"6'-0"32'-4"7,898:9,6384,563 / 9,638 = 48%R-3, RESIDENTIAL MEDIUM DENSITY DISTRICTR-2, APARTMENT HOUSESTYPE V-BCLASS A1-HOUR RATED, FIRE BARRIER1:150% Townhomes46'-0"15'-0"5'-0"20'-0"6'-0"GENERALA0.0 COVER SHEETA0.1 PROJECT INFORMATIONA0.2 MATERIAL SAMPLE BOARD & ASSEMBLIESCIVIL1 OF 2 TOPOGRAPHIC SURVEYDEMOD1.1 DEMO SITE PLANARCHITECTURALA1.1 SITE PLANA2.4 NOTED BASEMENT FLOOR PLANA2.5 NOTED FIRST FLOOR PLANA2.6 NOTED SECOND FLOOR PLANA2.7 COVERED SURFACE PARKING PLANSA4.1 ROOF PLANA6.1 BUILDING ELEVATIONSA6.2 BUILDING ELEVATIONSA6.3 BUILDING ELEVATIONS2345678910FEDCBAGH1NOT FOR CONSTRUCTIONREVISIONSPROJECT NO:DATE:22002August 30, 2023All reports, drawings, specifications, computer files, field data, notes, other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect, LocalElementArchitects, LLC. The Architect shall retain all common law, statutory and other reserved rights, including copyright thereto. The use of this drawing shall be restricted to the original site for which it was prepared and publication thereof is expressly limited to such use. Reuse, reproduction or publication by any method is prohibited without written consent from LocalElementArchitects, LLC. NCOA SUBMITTAL10/9/2024 2:27:00 PM C:\Users\chris\OneDrive\Documents\Villard Floor Plans_Central_chrisTMMND.rvtLAYERCAKE TOWNHOMES314 W VILLARD STBOZEMAN, MT 59715A0.1PROJECTINFORMATIONPROJECT TEAMSHEET INDEXSYMBOLSCODE ANALYSIS - IRCNORTHVICINITY MAPSITEW BEALL STN 5TH AVEPROJECT DESCRIPTIONTHREE-HOUSEHOLD DWELLINGS WITH THREE BASEMENT ACCESSORY LIVING UNITS AND DETACHED RESIDENTIAL COVERED PARKINGOWNER:AILESBURY 314, LLC555 ALVARADO ST. SAN FRANCISCO, CA 94114CONTACT: CATHERINE WOODSARCHITECT:LOCAL ELEMENT ARCHITECTS23 APEX DR. STE #100BOZEMAN MT, 59718P: 406.600.0408CONTACT:CHRIS YELEYCONTRACTOR:TO BE DETERMINEDSTRUCTURAL ENGINEER:TO BE DETERMINEDN 3RD AVEW VILLARD STUNIT 1 AREA CALCULATIONSNAMEAREACOVERED PATIOBASEMENT PATIO102 SFFRONT ENTRY22 SFCOVERED PATIO124 SFLIVABLEUNIT 1 ALU515 SFUNIT 1 BASEMENT597 SFUNIT 1 MAIN FLOOR 1032 SFUNIT 1 UPPER LEVEL 1132 SFLIVABLE3276 SF3400 SFUNIT 2 AREA CALCULATIONSNAMEAREACOVERED PATIOBASEMENT PATIO97 SFFRONT ENTRY20 SFCOVERED PATIO118 SFLIVABLEUNIT 2 BASEMENT575 SFUNIT 2 ALU504 SFUNIT 2 MAIN FLOOR 1007 SFUNIT 2 UPPER LEVEL 1105 SFLIVABLE3191 SF3309 SFUNIT 3 AREA CALCULATIONSNAMEAREACOVERED PATIOBASEMENT PATIO103 SFFRONT ENTRY22 SFCOVERED PATIO125 SFLIVABLEUNIT 3 ALU516 SFUNIT 3 BASEMENT596 SFUNIT 3 MAIN FLOOR 1032 SFUNIT 3 UPPER LEVEL 1130 SFLIVABLE3274 SF3398 SF11COVERED SURFACE PARKING...NAMEAREACOVERED PARKING 1456 SF1456 SF2REVISIONSNO. DATE DESCRIPTION1 08/22/2024 NCOA Revision 12 10/05/2024 NCOA Revision 2