HomeMy WebLinkAbout034 - PSK-1 - Plumbing Site PlanDN
DN
DN
DN
UP
UP
UP
A A
B B
C C
D D
xb xb
E E
xc xc
F F
xd xd
G G
H H
J J
1
1
x1
x1
2
2
3
3
4
4
x2
x2
x3
x3
x4
x4
x6
x6
7
7
8
8
9
9
10
105
5
6
6
Bx
Bx
Cx
Cx
6"ø FP-WET
4"ø CW 6"ø SAN6"ø SAN
NG
8"ø SD
6"ø SD
6"ø SD
A A
B B
C C
D D
xb xb
E E
xc xc
F F
xd xd
G G
H H
J J
1
1
x1
x1
2
2
3
3
4
4
x2
x2
x3
x3
x4
x4
x6
x6
7
7
8
8
9
9
10
105
5
6
6
Bx
Bx
Cx
Cx NATURAL GAS SERVICE -44 METERSPSK-1
3ELECTRICAL SERVICEG G
H H
J J
7
7
6" FIRE SERVICE
4" WATER SERVICE
HWH
H01
HWH
H02
PIPING OVERHEAD
7' - 6 1/2"17' - 10"SERVICE GATE VALVE
4" DOMESTIC WATER SERVICE
18" MIN SPOOL SECTION
WATER METER/STRAINER ASSEMBLY PER COB REQUIREMENTS
18" MIN SPOOL SECTION
REDUCED PRESSURE ZONE ASSEMBLY BACKFLOW PREVENTER
BUILDING PRESSURE REGULATING VALVE
ZONE PRESSURE REGULATING VALVE
ZONE PRESSURE REGULATING VALVE
6" FIRE WATER SERVICE
FIRE DEPARTMENT CONNECTION
SERVICE GATE VALVE
DOUBLE CHECK BACKFLOW PREVENTER
CHECK VALVE WITH BYPASS FOR
FORWARD-FLOW TESTING
WET MAIN FLOOR RISER
WET STANDPIPE RISER
PARKING GARAGE AND ATTIC DRY RISER
3" TO LEVELS 2 THROUGH 5
2" TO LEVEL 1
FIRE MAIN DRAIN
ACE JOB 23BZ5863
12 N. BROADWAY
SECOND FLOOR
BELGRADE, MT 59714
406-388-3320
SHEET NO.:
TITLE:
COPYRIGHT 2021 SMA, P.C.
REVISIONS:
KEYMAP:
ARCHITECT/ENGINEER SEAL:
PROJECT:
PROJECT LOCATION:
PREPARED FOR:
OWNER LOGO:
CONSULTANT LOGO/CONTACT:
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
TEAM:
PHASE:
DATE:
SMA PROJECT NUMBER:Plot Date:AHJ APPROVAL:
THIS SHEET IS INTENDED TO BE
PRINTED IN COLOR
HELENA
P: 406-442-4933
BOZEMAN
P: 406-219-2216
www.sma.design
09/04/2024 03:31:55 PMPSK-1
22-106
2024-08-30
SITE SUBMITTAL PLUMBING
SKETCHES
NT
KW
BRICK CAPITAL BLOCK 104
22-106
805 N IDA, 622 E TAMARACK ST
BOZEMAN, MT 59715
BRICK CAPITAL
SITE PLAN APPLICATION
N
1/16" = 1'-0"PSK-1
1 SITE PLUMBING CONNECTION PLAN
N
1/16" = 1'-0"PSK-1
2 FIRST FLOOR SCHEMATIC PLUMBING PLAN
N
1/2" = 1'-0"PSK-1
3 RISER ROOM ENLARGED PLUMBING PLAN
NOT TO SCALE4WATER RISER ISOMETRIC
220 1042 4" 4" 4" RPZA 145 2" @ 80 PSIG 3" @ 95 PSIG
PEAK
DEMAND
(GPM)
PEAK
DEMAND
(WSFU)
SERVICE
LINE SIZE
METER
SIZE
BACKFLOW
PREVENTER
SIZE
BACKFLOW
PREVENTER
TYPE
STATIC
PRESSURE
AT SERVICE
PRESSURE
REDUCING
VALVE
(ZONE 1 -
LEVELS 1 & 2)
PRESSURE
REDUCING
VALVE
(ZONE 2 -
LEVELS 3-5)
DOMESTIC WATER SERVICE SCHEDULE
TOTAL FIXTURE LOAD - UPC CHAPTER 6 1113
URINAL (FLUSHOMETER VALVE) UPC TABLE 610.10 0 0
WATER CLOSET (FLUSHOMETER VALVE) UPC TABLE 610.10 3 90
WATER CLOSET (1.6 GPF - FLUSHOMETER TANK) 2.5 0 0
WATER CLOSET (1.6 GPF - GRAVITY TANK) 2.5 86 215
LAUNDRY SINK 1.5 0 0
KITCHEN SINK 1.5 42 63
LAVATORY SINK 1.0 146 146
SERVICE/MOP BASIN 3 10 30
DRINKING FOUNTAIN 0.5 1 0.5
ADDITIONAL HOSE BIBB (EACH) 1 15 15
HOSE BIBB 2.5 1 2.5
DISHWASHER 1.5 42 63
CLOTHES WASHER 4 42 168
SHOWER (PER HEAD) 2 65 130
SOAKER TUB 10 13 130
BATHTUB/COMBINATION TUB/SHOWER 4 15 60
FIXTURE TYPE WATER SUPPLY
FIXTURE UNITS / FIX.FIXTURE COUNT TOTAL WSFU
COMMERCIAL WATER SERVICE CALCULATIONS - NEW
CONSTRUCTION
NOTES:
1. PLUMBING DOMESTIC WATER SYSTEM SIZING IN ACCORDANCE WITH THE 2021 UPC APPENDIX A.
2. CONTRACTOR SHALL VERIFY SITE WATER SUPPLY STATIC PRESSURE AND SHALL NOTE DISCREPANCIES TO THE ENGINEER.
3. SITE CONTRACTOR SHALL PROVIDE WATER SERVICE PIPING AND ACCESSORIES UP TO AND INCLUDING THE SERVICE GATE VALVE. SITE
CONTRACTOR SHALL PROVIDE DISINFECTION, FLUSHING, PRESSURE TESTING, AND BACTERIOLOGICAL TESTING OF THE SERVICE PIPING.
PLUMBING CONTRACTOR SHALL PROVIDE PIPING AND ACCESSORIES DOWNSTREAM OF THE SERVICE GATE VALVE.
4. COORDINATE WITH THE CITY OF BOZEMAN FOR PROCUREMENT AND INSTALLATION OF THE SERVICE WATER METER.
5. SEE PLUMBING SECTIONS AND DETAILS FOR ADDITIONAL REQUIREMENTS.
NOTES:
1. FIXTURE TAKEOFF AND ASSOCIATED SERVICE CALCULATION IN ACCORDANCE WITH 2021 UPC CHAPTER 6 AND THE CITY OF BOZEMAN
WATER SERVICE WORKSHEET. FIXTURE COUNTS AND CALCULATION PROVIDE ONLY FOR PERMITTING WITH THE CITY OF BOZEMAN.
CONTRACTOR SHALL NOT UTILIZE INFORMATION FOR ANY BIDDING OR CONSTRUCTION PURPOSES.
TOTAL 13,578 MBH
EQ-## DWELLING UNIT DOAS SYSTEM 490 MBH
EQ-## COORIDOR HEATING/COOLING RTU 100 MBH
EQ-## UNIT FIREPLACES (ALLOWANCE) 4293 MBH
EQ-## UNIT BBQ'S (ALLOWANCE) 975 MBH
EQ-## UNIT RANGES (ALLOWANCE) 5625 MBH
EQ-## GARAGE & SNOWMELT BOILERS 1197 MBH
EQ-## SPA BOILER 399 MBH
EQ-## LOBBY OUTDOOR FIREPLACE 399 MBH
EQ-## LOBBY INDOOR FIREPLACE 100 MBH
TAG DESCRIPTION
ITEM INPUT DEMAND DEMAND UNITS
NATURAL GAS FUEL LOAD SUMMARY - TOTAL BUILDING
LOAD
NOTES:
1. EACH DWELLING UNIT AS WELL AS THE LOBBY SPACE AND COMMERCIAL LEASE SPACE SHALL BE PROVIDED WITH A NATURAL GAS METER.
40 METERS ARE ANTICIPATED TO SERVE THE BUILDING.
2. EQUIPMENT INPUT DEMAND AT SITE ELEVATION IS BASED ON "ANSI Z21-13/CSA 4.9 INPUT RATING REQUIREMENTS AT SITE ELEVATION"
OR THE PUBLISHED INPUT DEMAND RATING AT SITE ELEVATION BY THE EQUIPMENT MANUFACTURER.
3. SYSTEM DELIVERY PRESSURE SHALL BE 2 PSIG AND SHALL BE REDUED TO 14" W.C. AT EACH PIECE OR GROUP OF EQUIPMENT OR UNIT
SERVICE VALVE. COORDINATE WITH THE LOCAL UTILITY PROVIDER.
4. MOST REMOTE FIXTURE IS EQ-### ~#### FEET EQUIVALENT PIPE LENGTH FROM METER.
5. PLUMBING CONTRACTOR SHALL PRIME AND PAINT ALL NATURAL GAS PIPING ON THE BUILDING EXTERIOR TO MATCH THE BUILDING
COLOR. COORDINATE WITH GENERAL CONTRACTOR.
6. SEE BUILDING PLUMBING DRAWINGS FOR COORDIANTION AND ADDITIONAL REQUIREMENTS.
NO.DATE REVISION DESCRIPTION