Loading...
HomeMy WebLinkAbout034 - PSK-1 - Plumbing Site PlanDN DN DN DN UP UP UP A A B B C C D D xb xb E E xc xc F F xd xd G G H H J J 1 1 x1 x1 2 2 3 3 4 4 x2 x2 x3 x3 x4 x4 x6 x6 7 7 8 8 9 9 10 105 5 6 6 Bx Bx Cx Cx 6"ø FP-WET 4"ø CW 6"ø SAN6"ø SAN NG 8"ø SD 6"ø SD 6"ø SD A A B B C C D D xb xb E E xc xc F F xd xd G G H H J J 1 1 x1 x1 2 2 3 3 4 4 x2 x2 x3 x3 x4 x4 x6 x6 7 7 8 8 9 9 10 105 5 6 6 Bx Bx Cx Cx NATURAL GAS SERVICE -44 METERSPSK-1 3ELECTRICAL SERVICEG G H H J J 7 7 6" FIRE SERVICE 4" WATER SERVICE HWH H01 HWH H02 PIPING OVERHEAD 7' - 6 1/2"17' - 10"SERVICE GATE VALVE 4" DOMESTIC WATER SERVICE 18" MIN SPOOL SECTION WATER METER/STRAINER ASSEMBLY PER COB REQUIREMENTS 18" MIN SPOOL SECTION REDUCED PRESSURE ZONE ASSEMBLY BACKFLOW PREVENTER BUILDING PRESSURE REGULATING VALVE ZONE PRESSURE REGULATING VALVE ZONE PRESSURE REGULATING VALVE 6" FIRE WATER SERVICE FIRE DEPARTMENT CONNECTION SERVICE GATE VALVE DOUBLE CHECK BACKFLOW PREVENTER CHECK VALVE WITH BYPASS FOR FORWARD-FLOW TESTING WET MAIN FLOOR RISER WET STANDPIPE RISER PARKING GARAGE AND ATTIC DRY RISER 3" TO LEVELS 2 THROUGH 5 2" TO LEVEL 1 FIRE MAIN DRAIN ACE JOB 23BZ5863 12 N. BROADWAY SECOND FLOOR BELGRADE, MT 59714 406-388-3320 SHEET NO.: TITLE: COPYRIGHT 2021 SMA, P.C. REVISIONS: KEYMAP: ARCHITECT/ENGINEER SEAL: PROJECT: PROJECT LOCATION: PREPARED FOR: OWNER LOGO: CONSULTANT LOGO/CONTACT: PROJECT NUMBER: DRAWN BY: CHECKED BY: TEAM: PHASE: DATE: SMA PROJECT NUMBER:Plot Date:AHJ APPROVAL: THIS SHEET IS INTENDED TO BE PRINTED IN COLOR HELENA P: 406-442-4933 BOZEMAN P: 406-219-2216 www.sma.design 09/04/2024 03:31:55 PMPSK-1 22-106 2024-08-30 SITE SUBMITTAL PLUMBING SKETCHES NT KW BRICK CAPITAL BLOCK 104 22-106 805 N IDA, 622 E TAMARACK ST BOZEMAN, MT 59715 BRICK CAPITAL SITE PLAN APPLICATION N 1/16" = 1'-0"PSK-1 1 SITE PLUMBING CONNECTION PLAN N 1/16" = 1'-0"PSK-1 2 FIRST FLOOR SCHEMATIC PLUMBING PLAN N 1/2" = 1'-0"PSK-1 3 RISER ROOM ENLARGED PLUMBING PLAN NOT TO SCALE4WATER RISER ISOMETRIC 220 1042 4" 4" 4" RPZA 145 2" @ 80 PSIG 3" @ 95 PSIG PEAK DEMAND (GPM) PEAK DEMAND (WSFU) SERVICE LINE SIZE METER SIZE BACKFLOW PREVENTER SIZE BACKFLOW PREVENTER TYPE STATIC PRESSURE AT SERVICE PRESSURE REDUCING VALVE (ZONE 1 - LEVELS 1 & 2) PRESSURE REDUCING VALVE (ZONE 2 - LEVELS 3-5) DOMESTIC WATER SERVICE SCHEDULE TOTAL FIXTURE LOAD - UPC CHAPTER 6 1113 URINAL (FLUSHOMETER VALVE) UPC TABLE 610.10 0 0 WATER CLOSET (FLUSHOMETER VALVE) UPC TABLE 610.10 3 90 WATER CLOSET (1.6 GPF - FLUSHOMETER TANK) 2.5 0 0 WATER CLOSET (1.6 GPF - GRAVITY TANK) 2.5 86 215 LAUNDRY SINK 1.5 0 0 KITCHEN SINK 1.5 42 63 LAVATORY SINK 1.0 146 146 SERVICE/MOP BASIN 3 10 30 DRINKING FOUNTAIN 0.5 1 0.5 ADDITIONAL HOSE BIBB (EACH) 1 15 15 HOSE BIBB 2.5 1 2.5 DISHWASHER 1.5 42 63 CLOTHES WASHER 4 42 168 SHOWER (PER HEAD) 2 65 130 SOAKER TUB 10 13 130 BATHTUB/COMBINATION TUB/SHOWER 4 15 60 FIXTURE TYPE WATER SUPPLY FIXTURE UNITS / FIX.FIXTURE COUNT TOTAL WSFU COMMERCIAL WATER SERVICE CALCULATIONS - NEW CONSTRUCTION NOTES: 1. PLUMBING DOMESTIC WATER SYSTEM SIZING IN ACCORDANCE WITH THE 2021 UPC APPENDIX A. 2. CONTRACTOR SHALL VERIFY SITE WATER SUPPLY STATIC PRESSURE AND SHALL NOTE DISCREPANCIES TO THE ENGINEER. 3. SITE CONTRACTOR SHALL PROVIDE WATER SERVICE PIPING AND ACCESSORIES UP TO AND INCLUDING THE SERVICE GATE VALVE. SITE CONTRACTOR SHALL PROVIDE DISINFECTION, FLUSHING, PRESSURE TESTING, AND BACTERIOLOGICAL TESTING OF THE SERVICE PIPING. PLUMBING CONTRACTOR SHALL PROVIDE PIPING AND ACCESSORIES DOWNSTREAM OF THE SERVICE GATE VALVE. 4. COORDINATE WITH THE CITY OF BOZEMAN FOR PROCUREMENT AND INSTALLATION OF THE SERVICE WATER METER. 5. SEE PLUMBING SECTIONS AND DETAILS FOR ADDITIONAL REQUIREMENTS. NOTES: 1. FIXTURE TAKEOFF AND ASSOCIATED SERVICE CALCULATION IN ACCORDANCE WITH 2021 UPC CHAPTER 6 AND THE CITY OF BOZEMAN WATER SERVICE WORKSHEET. FIXTURE COUNTS AND CALCULATION PROVIDE ONLY FOR PERMITTING WITH THE CITY OF BOZEMAN. CONTRACTOR SHALL NOT UTILIZE INFORMATION FOR ANY BIDDING OR CONSTRUCTION PURPOSES. TOTAL 13,578 MBH EQ-## DWELLING UNIT DOAS SYSTEM 490 MBH EQ-## COORIDOR HEATING/COOLING RTU 100 MBH EQ-## UNIT FIREPLACES (ALLOWANCE) 4293 MBH EQ-## UNIT BBQ'S (ALLOWANCE) 975 MBH EQ-## UNIT RANGES (ALLOWANCE) 5625 MBH EQ-## GARAGE & SNOWMELT BOILERS 1197 MBH EQ-## SPA BOILER 399 MBH EQ-## LOBBY OUTDOOR FIREPLACE 399 MBH EQ-## LOBBY INDOOR FIREPLACE 100 MBH TAG DESCRIPTION ITEM INPUT DEMAND DEMAND UNITS NATURAL GAS FUEL LOAD SUMMARY - TOTAL BUILDING LOAD NOTES: 1. EACH DWELLING UNIT AS WELL AS THE LOBBY SPACE AND COMMERCIAL LEASE SPACE SHALL BE PROVIDED WITH A NATURAL GAS METER. 40 METERS ARE ANTICIPATED TO SERVE THE BUILDING. 2. EQUIPMENT INPUT DEMAND AT SITE ELEVATION IS BASED ON "ANSI Z21-13/CSA 4.9 INPUT RATING REQUIREMENTS AT SITE ELEVATION" OR THE PUBLISHED INPUT DEMAND RATING AT SITE ELEVATION BY THE EQUIPMENT MANUFACTURER. 3. SYSTEM DELIVERY PRESSURE SHALL BE 2 PSIG AND SHALL BE REDUED TO 14" W.C. AT EACH PIECE OR GROUP OF EQUIPMENT OR UNIT SERVICE VALVE. COORDINATE WITH THE LOCAL UTILITY PROVIDER. 4. MOST REMOTE FIXTURE IS EQ-### ~#### FEET EQUIVALENT PIPE LENGTH FROM METER. 5. PLUMBING CONTRACTOR SHALL PRIME AND PAINT ALL NATURAL GAS PIPING ON THE BUILDING EXTERIOR TO MATCH THE BUILDING COLOR. COORDINATE WITH GENERAL CONTRACTOR. 6. SEE BUILDING PLUMBING DRAWINGS FOR COORDIANTION AND ADDITIONAL REQUIREMENTS. NO.DATE REVISION DESCRIPTION